Literature DB >> 22438512

Regression-based cardiac motion prediction from single-phase CTA.

Coert T Metz1, Nora Baka, Hortense Kirisli, Michiel Schaap, Stefan Klein, Lisan A Neefjes, Nico R Mollet, Boudewijn Lelieveldt, Marleen de Bruijne, Wiro J Niessen, Theo van Walsum.   

Abstract

State of the art cardiac computed tomography (CT) enables the acquisition of imaging data of the heart over the entire cardiac cycle at concurrent high spatial and temporal resolution. However, in clinical practice, acquisition is increasingly limited to 3-D images. Estimating the shape of the cardiac structures throughout the entire cardiac cycle from a 3-D image is therefore useful in applications such as the alignment of preoperative computed tomography angiography (CTA) to intra-operative X-ray images for improved guidance in coronary interventions. We hypothesize that the motion of the heart is partially explained by its shape and therefore investigate the use of three regression methods for motion estimation from single-phase shape information. Quantitative evaluation on 150 4-D CTA images showed a small, but statistically significant, increase in the accuracy of the predicted shape sequences when using any of the regression methods, compared to shape-independent motion prediction by application of the mean motion. The best results were achieved using principal component regression resulting in point-to-point errors of 2.3±0.5 mm, compared to values of 2.7±0.6 mm for shape-independent motion estimation. Finally, we showed that this significant difference withstands small variations in important parameter settings of the landmarking procedure.

Mesh:

Year:  2012        PMID: 22438512     DOI: 10.1109/TMI.2012.2190938

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  2 in total

1.  eCurves: A Temporal Shape Encoding.

Authors:  Elena Bernardis; Yong Zhang; Ender Konukoglu; Yangming Ou; Harold S Javitz; Leon Axel; Dimitris Metaxas; Benoit Desjardins; Kilian M Pohl
Journal:  IEEE Trans Biomed Eng       Date:  2017-06-16       Impact factor: 4.538

2.  Echo planar imaging-induced errors in intracardiac 4D flow MRI quantification.

Authors:  Jos J M Westenberg; Hans C van Assen; Pieter J van den Boogaard; Jelle J Goeman; Hicham Saaid; Jason Voorneveld; Johan Bosch; Sasa Kenjeres; Tom Claessens; Pankaj Garg; Marc Kouwenhoven; Hildo J Lamb
Journal:  Magn Reson Med       Date:  2021-12-05       Impact factor: 3.737

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.