Literature DB >> 22438188

MedJet--a new CO2-based disposable cleaning device allows safe and effective bowel cleansing during colonoscopy: a pilot study.

R Kiesslich1, N Schuster, A Hoffman, M Goetz, P R Galle, E Santo, Z Halpern.   

Abstract

BACKGROUND AND STUDY AIMS: Complete bowel cleansing is mandatory for effective colon cancer screening and surveillance. The aim of the current pilot study, which was conducted in humans, was to test the safety and efficiency of a newly developed disposable cleaning device, the MedJet, for intraprocedural bowel cleansing. PATIENTS AND METHODS: Patients with screening or surveillance colonoscopy after previous polypectomy were included. The colonoscope was first inserted to the cecum and the overall cleansing was assessed according to the Ottawa scale. The MedJet device was used if colon cleansing had been incomplete. The MedJet catheter was passed over the working channel of the colonoscope and the colon was cleaned during withdrawal. The MedJet device delivered controlled jets comprising compressed CO2 and minimal amounts of sterile water, which allowed disintegration and removal of residual stool. The efficiency of cleaning was assessed according to the Boston scale.
RESULTS: A total of 32 patients (16 female; mean age 61 years) were treated with the device. No device-related adverse or serious adverse events were noted. MedJet application during withdrawal provided effective and significant improvement in bowel cleansing (P = 0.005). Furthermore, 18 adenomas and 1 colon cancer, which were hidden behind stool remnants, could be identified in 11 patients following use of the MedJet device. However, the withdrawal times were prolonged (11.4±6.0 minutes) due to the additional cleaning procedure. All patients tolerated the procedure well.
CONCLUSIONS: The new MedJet device enabled highly effective and safe bowel cleansing during colonoscopy. The catheter-based system was easy to use and CO2 was applied for cleansing. The procedure was well tolerated by patients. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22438188     DOI: 10.1055/s-0031-1291703

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  5 in total

1.  Intraprocedural bowel cleansing with the JetPrep cleansing system improves adenoma detection.

Authors:  Arthur Hoffman; Sanjay Murthy; Lena Pompetzki; Johannes Wilhelm Rey; Martin Goetz; Achim Tresch; Peter Robert Galle; Ralf Kiesslich
Journal:  World J Gastroenterol       Date:  2015-07-14       Impact factor: 5.742

Review 2.  Achieving the best bowel preparation for colonoscopy.

Authors:  Adolfo Parra-Blanco; Alex Ruiz; Manuel Alvarez-Lobos; Ana Amorós; Juan Cristóbal Gana; Patricio Ibáñez; Akiko Ono; Takahiro Fujii
Journal:  World J Gastroenterol       Date:  2014-12-21       Impact factor: 5.742

Review 3.  Advanced endoscopic technologies for colorectal cancer screening.

Authors:  Keith L Obstein; Pietro Valdastri
Journal:  World J Gastroenterol       Date:  2013-01-28       Impact factor: 5.742

Review 4.  What Influences the Quality of Prevention Colonoscopy?

Authors:  Wolfgang Schmidt-Tänzer; Axel Eickhoff
Journal:  Viszeralmedizin       Date:  2014-02

5.  Aquanet Bowel Cleansing Device Versus Oral Sodium Picosulfate for Pre-Endoscopy Bowel Preparation: Propensity Score Analysis for Interventional Effectiveness Evaluation.

Authors:  Roberto L Kaiser Junior; Luiz G de Quadros; Mikaell A G Faria; Fernanda S L Kaiser; Juan C O Campo; Idiberto J Zotarelli Filho
Journal:  Gastroenterology Res       Date:  2018-02-23
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.