Literature DB >> 22437686

Reliability and accuracy of a radiographic analysis method for posterior maxillary mini-implant location.

Luís Carlos Sampaio Dias1, Yomara Barreto da Costa Ferreira, Rudys Rodolfo de Jesus Tavarez, Célia Regina Maio Pinzan-Vercelino, Júlio de Araújo Gurgel.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the reliability and accuracy of a radiographic analysis method for the location of mini-implants inserted in the posterior region of the maxilla.
MATERIAL AND METHODS: Two self-drilling mini-implants were installed between the second premolar and the first molar on the right side and left side in three dry skulls. Three operators performed three occlusal radiographs, using an occlusal x-ray film holder, at three different times in each of the three skulls.
RESULTS: The interclass correlation coefficient showed a significantly high, positive correlation (p<0.05), indicating an excellent reliability between operators. The analysis of variance showed no significant differences in time and among the operators.
CONCLUSION: Based of these findings, it may be concluded that this methodology can be used by several operators in longitudinal clinical studies on orthodontic mini-implants at the anterior-posterior and lateral-medial locations or longitudinal displacement.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22437686      PMCID: PMC3928780          DOI: 10.1590/s1678-77572012000100018

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


  16 in total

1.  Histologic and histomorphometric evaluation of peri-implant bone subjected to immediate loading: an experimental study with Macaca fascicularis.

Authors:  George E Romanos; Chooi Gait Toh; Chong Huat Siar; Dasan Swaminathan
Journal:  Int J Oral Maxillofac Implants       Date:  2002 Jan-Feb       Impact factor: 2.804

2.  Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion.

Authors:  H S Park; S M Bae; H M Kyung; J H Sung
Journal:  J Clin Orthod       Date:  2001-07

3.  Do miniscrews remain stationary under orthodontic forces?

Authors:  Eric J W Liou; Betty C J Pai; James C Y Lin
Journal:  Am J Orthod Dentofacial Orthop       Date:  2004-07       Impact factor: 2.650

4.  Skeletal and dental changes following surgically assisted rapid palatal expansion.

Authors:  Friedrich K Byloff; Claude F Mossaz
Journal:  Eur J Orthod       Date:  2004-08       Impact factor: 3.075

5.  Factors affecting the clinical success of screw implants used as orthodontic anchorage.

Authors:  Hyo-Sang Park; Seong-Hwa Jeong; Oh-Won Kwon
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-07       Impact factor: 2.650

6.  Mini- and micro-screws for temporary skeletal anchorage in orthodontic therapy.

Authors:  Axel Berens; Dirk Wiechmann; Rupert Dempf
Journal:  J Orofac Orthop       Date:  2006-11       Impact factor: 1.938

7.  Clinical use of miniscrew implants as orthodontic anchorage: success rates and postoperative discomfort.

Authors:  Shingo Kuroda; Yasuyo Sugawara; Toru Deguchi; Hee-Moon Kyung; Teruko Takano-Yamamoto
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-01       Impact factor: 2.650

Review 8.  Systematic review of the experimental use of temporary skeletal anchorage devices in orthodontics.

Authors:  Marie A Cornelis; Nicole R Scheffler; Hugo J De Clerck; J F Camilla Tulloch; Catherine Nyssen Behets
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-04       Impact factor: 2.650

9.  Reliability and accuracy of cone-beam computed tomography dental measurements.

Authors:  Sebastian Baumgaertel; J Martin Palomo; Leena Palomo; Mark G Hans
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-07       Impact factor: 2.650

10.  Mini-implant for orthodontic anchorage.

Authors:  R Kanomi
Journal:  J Clin Orthod       Date:  1997-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.