Literature DB >> 22437458

Totally endoscopic robotic ventricular septal defect repair.

Changqing Gao1, Ming Yang, Gang Wang, Jiali Wang, Cangsong Xiao, Yue Zhao.   

Abstract

OBJECTIVE: Recent advances in robotic instrumentation have facilitated totally endoscopic intracardiac procedures. However, totally endoscopic robotic ventricular septal defect (VSD) repair has not been reported in the literatures to our knowledge. We report our first three cases of closed chest VSD repair using da Vinci S Surgical System.
METHODS: Three female patients underwent totally endoscopic robotic VSD repair. Echocardiography demonstrated that the perimembranous VSD sizes in three patients were 6, 8, and 8 mm, respectively, and a patent foramen ovale in one patient.
RESULTS: All the VSD repair and right atrial closure were completed with the da Vinci robot. Mean cardiopulmonary bypass and mean cross-clamp times were 70 and 22 minutes, respectively. No blood transfusions were received. Postoperative transesophagel echocardiogram (TEE) demonstrated intact ventricular septum. The mean hospital stay was 5 days. The patients returned to normal function without any complications.
CONCLUSIONS: With a limited number of cases, the study showed that totally endoscopic robotic VSD repair in adult patients is feasible and safe.

Entities:  

Year:  2010        PMID: 22437458     DOI: 10.1097/IMI.0b013e3181ee94cb

Source DB:  PubMed          Journal:  Innovations (Phila)        ISSN: 1556-9845


  2 in total

Review 1.  Robotic technology in cardiovascular medicine.

Authors:  Johannes Bonatti; George Vetrovec; Celia Riga; Oussama Wazni; Petr Stadler
Journal:  Nat Rev Cardiol       Date:  2014-03-25       Impact factor: 32.419

2.  Totally robotic repair of atrioventricular septal defect in the adult.

Authors:  Changqing Gao; Ming Yang; Cangsong Xiao; Huajun Zhang
Journal:  J Cardiothorac Surg       Date:  2015-11-06       Impact factor: 1.637