Literature DB >> 22437423

Lag screw fixation of medial malleolar fractures: a biomechanical, radiographic, and clinical comparison of unicortical partially threaded lag screws and bicortical fully threaded lag screws.

William M Ricci1, Paul Tornetta, Joseph Borrelli.   

Abstract

OBJECTIVES: Bicortical fully threaded (FT) lag screw fixation (lag by method) is a technique for medial malleolar fixation that may provide advantages to partially threaded (PT) cancellous lag screws (lag by screw design). A direct comparison of the biomechanical properties and the clinical outcomes of these 2 methods of medial malleolar lag screw fixation were undertaken. The null hypotheses were that unicortical PT lag screws and bicortical FT lag screws had similar biomechanical and clinical outcomes.
DESIGN: Biomechanics--Human cadaver biomechanical investigation. Clinical-Retrospective cohort series with control. Settings-Level-1 trauma center. PATIENTS: One hundred forty-one consecutive patients with closed medial malleolar fractures (OTA 44) treated with lag screw fixation were identified from a prospective orthopaedic trauma database. Thirty-nine were lost to follow-up and 12 were treated with a single screw leaving 46 in the PT group and 46 in the FT group all treated with 2 screws for their medial malleolar fracture. INTERVENTION: Biomechanics--Human cadavers (n = 3) had bilateral oblique medial malleolar fractures (n = 6) created with an osteotome to simulate a typical medial malleolar fracture amenable to lag screw fixation. Fixation of each side was randomly allocated to either two 4.0-mm PT lag screws (length 45 mm) or two 3.5-mm FT threaded screws [length determined by depth gauge after near cortex overdrilled and far cortex (distal lateral tibia) drilled based on core diameter (2.7 mm)]. Clinical-Either 2 traditional PT (n = 46) or 2 FT screws (n = 46) were used for fixation of medial malleolus fractures. MAIN OUTCOME MEASUREMENTS: Biomechanics--Peak insertion torque generated during screw insertion. Clinical: Radiographic evidence of screw loosening, clinical non-union, and reoperation.
RESULTS: Biomechanics--The FT lag screw group (n = 6 screws) showed an average maximum torque of 14.4 in-lbf (range 8.0-20.1, SD = 4.4) before screw stripping. This was over 3 times greater than that seen with the PT lag screws (n = 6) (average maximum torque generation = 4.0 in-lbf, range 2.5-6.6, SD = 1.4), P < 0.0002. Clinical-Radiographic screw loosening was evident in one of the 46 patients (2%) in the FT cohort and in 11 of the 46 patients (24%) in the PT cohort, P < 0.003. Two of the patients with screw loosening in the PT cohort required reoperation for removal of symptomatic hardware, whereas no patient from the LT screw group required removal. All patients in the LT cohort healed after the index procedure although 2 in the PT cohort had nonunions.
CONCLUSIONS: Screws placed with the lag by method technique that engaged the distal lateral tibial cortex have superior biomechanical, radiographic, and clinical outcomes compared to traditional PT screws for the fixation of medial malleolar fractures.

Entities:  

Mesh:

Year:  2012        PMID: 22437423     DOI: 10.1097/BOT.0b013e3182404512

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  16 in total

Review 1.  [Ankle fractures in older patients : What should we do differently?]

Authors:  Sabine Ochman; Michael J Raschke
Journal:  Unfallchirurg       Date:  2021-02-10       Impact factor: 1.000

2.  Biomechanical testing of a novel osteosynthesis plate for the ulnar coronoid process.

Authors:  Johannes Kiene; Jorn Bogun; Nina Brockhaus; Klaus Waizner; Arndt-Peter Schulz; Robert Wendlandt
Journal:  Shoulder Elbow       Date:  2014-05-06

Review 3.  Internal fixation of osteoporotic fractures.

Authors:  David L Rothberg; Mark A Lee
Journal:  Curr Osteoporos Rep       Date:  2015-02       Impact factor: 5.096

4.  Medial malleolus screws: out in one view and out.

Authors:  Jeffrey C Wera; David Seligson; John T Riehl
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-07-22

5.  Short Term Complications in Geriatric Ankle Fractures Using a Protocolized Approach to Surgical Treatment: Is Early Weight Bearing Safe?

Authors:  Gerard Chang; Tyler Henry; Keenan Sobol; James Krieg
Journal:  Iowa Orthop J       Date:  2020

6.  Biomechanical evaluation of medial malleolus fractures treated with headless compression screws.

Authors:  Robert M Corey; Lisa K Cannada; Gary Bledsoe; Heidi Israel
Journal:  J Clin Orthop Trauma       Date:  2018-04-23

7.  Comparison of Partially Threaded and Fully Threaded 4mm Cancellous Screws in Fixation of Medial Malleolar Fractures.

Authors:  Sayyed-Hadi Sayyed-Hosseinian; Farshid Bagheri; Mohammad-Hosien Ebrahimzadeh; Ali Moradi; Sogol Golshan
Journal:  Arch Bone Jt Surg       Date:  2020-11

8.  Efficacy of hook-type locking plate and partially threaded cancellous lag screw in the treatment of displaced medial malleolar fractures in elderly patients.

Authors:  Byung-Ki Cho; Jun-Beom Kim; Seung-Myung Choi
Journal:  Arch Orthop Trauma Surg       Date:  2021-06-05       Impact factor: 2.928

9.  The effect of screw thread length on initial stability of Schatzker type 1 tibial plateau fracture fixation: a biomechanical study.

Authors:  Ahmet Salduz; Fevzi Birisik; Gokhan Polat; Bugra Bekler; Ergun Bozdag; Onder Kilicoglu
Journal:  J Orthop Surg Res       Date:  2016-11-22       Impact factor: 2.359

10.  Anterograde Headless Cannulated Screw Fixation in the Treatment of Medial Malleolar Fractures: Evaluation of a New Technique and Its Outcomes.

Authors:  Ali Çağrı Tekin; Haluk Çabuk; Süleyman Semih Dedeoğlu; Mehmet Selçuk Saygılı; Müjdat Adaş; Cem Dinçay Büyükkurt; Hakan Gürbüz; Murat Çakar; Zeynep Nilüfer Tekin
Journal:  Med Princ Pract       Date:  2016-06-07       Impact factor: 1.927

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.