Optimizing normal tissue sparing in ion therapy using calculated isoeffective dose for ion selection.

Nicholas B Remmes1, Michael G Herman, Jon J Kruse.   

Abstract

PURPOSE: To investigate how the selection of ion type affects the calculated isoeffective dose to the surrounding normal tissue as a function of both normal tissue and target tissue α/β ratios. METHODS AND MATERIALS: A microdosimetric biologic dose model was incorporated into a Geant4 simulation of parallel opposed beams of protons, helium, lithium, beryllium, carbon, and neon ions. The beams were constructed to give a homogeneous isoeffective dose to a volume in the center of a water phantom for target tissues covering a range of cobalt equivalent α/β ratios of 1-20 Gy. Concomitant normal tissue isoeffective doses in the plateau of the ion beam were then compared for different ions across the range of normal tissue and target tissue radiosensitivities for a fixed isoeffective dose to the target tissue.
RESULTS: The ion type yielding the optimal normal tissue sparing was highly dependent on the α/β ratio of both the normal and the target tissue. For carbon ions, the calculated isoeffective dose to normal tissue at a 5-cm depth varied by almost a factor of 5, depending on the α/β ratios of the normal and target tissue. This ranges from a factor of 2 less than the isoeffective dose of a similar proton treatment to a factor of 2 greater.
CONCLUSIONS: No single ion is optimal for all treatment scenarios. The heavier ions are superior in cases in which the α/β ratio of the target tissue is low and the α/β ratio of normal tissue is high, and protons are superior in the opposite circumstances. Lithium and beryllium appear to offer dose advantages similar to carbon, with a considerably lower normal tissue dose when the α/β ratio in the target tissue is high and the α/β ratio in the normal tissue is low.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22436796     DOI: 10.1016/j.ijrobp.2011.08.006

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  3 in total

1.  New Ions for Therapy.

Authors:  Francesco Tommasino; Emanuele Scifoni; Marco Durante
Journal:  Int J Part Ther       Date:  2016-02-09

2.  Carbon ions of different linear energy transfer (LET) values induce apoptosis & G2 cell cycle arrest in radio-resistant melanoma cells.

Authors:  Žakula Jelena; Korićanac Lela; Keta Otilija; Todorović Danijela; A P Cirrone Giuseppe; Romano Francesco; Cuttone Giacomo; Petrović Ivan; Ristić-Fira Aleksandra
Journal:  Indian J Med Res       Date:  2016-05       Impact factor: 2.375

3.  Characterization of the Mixed Radiation Field Produced by Carbon and Oxygen Ion Beams of Therapeutic Energy: A Monte Carlo Simulation Study.

Authors:  C K Ying; David Bolst; Anatoly Rosenfeld; Susanna Guatelli
Journal:  J Med Phys       Date:  2019-12-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.