Four-dimensional measurement of the displacement of internal fiducial and skin markers during 320-multislice computed tomography scanning of breast cancer.

Hideomi Yamashita1, Kae Okuma, Keiichiro Tada, Kenshiro Shiraishi, Wataru Takahashi, Shino Shibata-Mobayashi, Akira Sakumi, Naoya Saotome, Akihiro Haga, Tsuyoshi Onoe, Kenji Ino, Masaaki Akahane, Kuni Ohtomo, Keiichi Nakagawa.   

Abstract

PURPOSE: To study the three-dimensional movement of internal tumor bed fiducial and breast skin markers, using 320-multislice computed tomography (CT); and to analyze intrafractional errors for breast cancer patients undergoing breast irradiation. METHODS AND MATERIALS: This study examined 280 markers on the skin of the breast (200 markers) and on the primary tumor bed (80 markers) of 20 patients treated by external-beam photon radiotherapy. Motion assessment was analyzed in 41 respiratory phases during 20 s of cine CT in the radiotherapy position. To assess intrafractional errors resulting from respiratory motion, four-dimensional CT scans were acquired for 20 patients.
RESULTS: Motion in the anterior-posterior (A/P) and superior-inferior (S/I) directions showed a strong correlation (|r| > 0.7) with the respiratory curve for most markers (79% and 70%, respectively). The average marker displacements between maximum and minimum value during 20 s for the 200 breast skin metal markers were 1.1 ± 0.3 mm, 2.1 ± 0.6 mm, and 1.6 ± 0.4 mm in the left-right, A/P, and S/I directions, respectively. For the 80 tumor bed clips, displacements were 0.9 ± 0.2 mm in left-right, 1.7 ± 0.5 mm in A/P, and 1.1 ± 0.3 mm in S/I. There was no significant difference in the motion between breast quadrant regions or between the primary site and the other regions.
CONCLUSIONS: Motion in primary breast tumors was evaluated with 320-multislice CT. Very little change was detected during individual radiation treatment fractions.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22436784     DOI: 10.1016/j.ijrobp.2011.12.030

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  9 in total

1.  Displacement of the lumpectomy cavity defined by surgical clips and seroma based on 4D-CT scan for external-beam partial breast irradiation after breast-conserving surgery: a comparative study.

Authors:  Y Ding; J Li; W Wang; S Wang; T Fan; M Xu; Q Shao; Z Ma
Journal:  Br J Radiol       Date:  2013-08-30       Impact factor: 3.039

2.  Are fiducial markers useful surrogates when using respiratory gating to reduce motion of gastroesophageal junction tumors?

Authors:  Fenghong Liu; Shu Ng; Florence Huguet; Ellen D Yorke; Gikas S Mageras; Karyn A Goodman
Journal:  Acta Oncol       Date:  2016-05-06       Impact factor: 4.089

3.  Assessment of respiration-induced displacement of canine abdominal organs in dorsal and ventral recumbency using multislice computed tomography.

Authors:  Cintia R Oliveira; Margaret A Henzler; Rebecca A Johnson; Randi Drees
Journal:  Vet Radiol Ultrasound       Date:  2014-08-18       Impact factor: 1.363

4.  Differences in displacement of the proximal and distal ends of mid-upper thoracic esophageal squamous cell carcinoma.

Authors:  Guoqin Qiu; Dengshun Wen; Xianghui DU; Liming Sheng; Xia Zhou; Yongling Ji; Wuan Bao; Danhong Zhang; Lei Cheng
Journal:  Mol Clin Oncol       Date:  2016-05-11

5.  Individually wide range of renal motion evaluated by four-dimensional computed tomography.

Authors:  Hideomi Yamashita; Mami Yamashita; Masahiko Futaguchi; Ryousuke Takenaka; Shino Shibata; Kentaro Yamamoto; Akihiro Nomoto; Akira Sakumi; Satoshi Kida; Yoshihiro Kaneko; Shigeharu Takenaka; Takashi Shiraki; Keiichi Nakagawa
Journal:  Springerplus       Date:  2014-03-07

6.  Four-dimensional measurement of the displacement of metal clips or postoperative surgical staples during 320-multislice computed tomography scanning of gastric cancer.

Authors:  Hideomi Yamashita; Kae Okuma; Wataru Takahashi; Akira Sakumi; Akihiro Haga; Kenji Ino; Masaaki Akahane; Kuni Ohtomo; Keiichi Nakagawa
Journal:  Radiat Oncol       Date:  2012-08-10       Impact factor: 3.481

7.  A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery.

Authors:  Yun Ding; Jianbin Li; Wei Wang; Suzhen Wang; Jinzhi Wang; Zhifang Ma; Qian Shao; Min Xu
Journal:  Radiat Oncol       Date:  2014-03-19       Impact factor: 3.481

8.  Comprehensive target geometric errors and margin assessment in stereotactic partial breast irradiation.

Authors:  Xin Zhen; Bo Zhao; Zhuoyu Wang; Robert Timmerman; Ann Spangler; Nathan Kim; Asal Rahimi; Xuejun Gu
Journal:  Radiat Oncol       Date:  2017-09-11       Impact factor: 3.481

9.  Comparison of rigid and deformable registration through the respiratory phases of four-dimensional computed tomography image data sets for radiotherapy after breast-conserving surgery.

Authors:  Aiping Zhang; Jianbin Li; Heng Qiu; Wei Wang; Yanluan Guo
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.