Literature DB >> 2243410

Steady and pulsatile flow fields in an end-to-side arterial anastomosis model.

M Ojha1, C R Ethier, K W Johnston, R S Cobbold.   

Abstract

We investigated the flow field within a rigid-walled in vitro model of an end-to-side 45 degree anastomosis in an attempt to identify possible hemodynamic factors that may contribute to the pathogenesis of distal anastomotic intimal hyperplasia. A high-resolution photochromic tracer technique was used to visualize the flow in orthogonal planes and to determine the axial wall shear stress profiles for both steady and pulsatile flows over a range of physiologically relevant conditions. The flow field showed qualitative similarities to those seen in curved vessel: rapidly moving fluid from the graft section affects the bed of the host vessel, that is, the wall opposite the anastomosis, eventually advancing down the host vessel in a spiraling motion. A small mobile separation zone was noted at the toe of the anastomosis. Comparison of wall shear stress profiles with previously reported preferential sites for the development of intimal hyperplasia supported a low wall shear stress and/or flow separation pathogenesis hypothesis. One notable exception was the bed of the host artery that appeared to be subjected to a complex hemodynamic environment.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2243410     DOI: 10.1067/mva.1990.24365

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  9 in total

1.  Numerical Simulation of Physiological Blood Flow in 2-way Coronary Artery Bypass Grafts.

Authors:  Aike Qiao; Youjun Liu; Siyang Li; Hu Zhao
Journal:  J Biol Phys       Date:  2005-05       Impact factor: 1.365

2.  Frequency of swing-segment stenosis in referred dialysis patients with angiographically documented lesions.

Authors:  Olurotimi J Badero; Moro O Salifu; Haimanot Wasse; Jack Work
Journal:  Am J Kidney Dis       Date:  2008-01       Impact factor: 8.860

3.  Numerical simulations of unsteady flows in a stenosed coronary bypass graft.

Authors:  V Deplano; C Bertolotti; O Boiron
Journal:  Med Biol Eng Comput       Date:  2001-07       Impact factor: 3.079

4.  Fluid-dynamic optimal design of helical vascular graft for stenotic disturbed flow.

Authors:  Hojin Ha; Dongha Hwang; Woo-Rak Choi; Jehyun Baek; Sang Joon Lee
Journal:  PLoS One       Date:  2014-10-31       Impact factor: 3.240

5.  Numerical investigation of blood flow in a deformable coronary bifurcation and non-planar branch.

Authors:  Seyed Esmail Razavi; Amir Ali Omidi; Massoud Saghafi Zanjani
Journal:  Bioimpacts       Date:  2014-12-30

6.  End-to-side Anastomosis on Digital Arteries: Just a Technical Choice or a Real Benefit?

Authors:  Luigi Troisi; Erica Tedone Clemente; Valentina Susca; Macarena Vizcay; Francesco Zanchetta; Sara Stucchi; Giorgio Eugenio Pajardi
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-09-30

7.  Hemodynamic characteristics of the vertebrobasilar system analyzed using MRI-based models.

Authors:  Amanda K Wake-Buck; J Christopher Gatenby; John C Gore
Journal:  PLoS One       Date:  2012-12-10       Impact factor: 3.240

8.  Computational model of blood flow in the aorto-coronary bypass graft.

Authors:  Meena Sankaranarayanan; Leok Poh Chua; Dhanjoo N Ghista; Yong Seng Tan
Journal:  Biomed Eng Online       Date:  2005-03-04       Impact factor: 2.819

9.  Flow patterns through vascular graft models with and without cuffs.

Authors:  Chia Min Leong; Gary B Nackman; Timothy Wei
Journal:  PLoS One       Date:  2018-02-23       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.