Literature DB >> 22425703

Automatic office blood pressure measured without doctors or nurses present.

Joji Ishikawa1, Efthimia G Nasothimiou, Nikos Karpettas, Scott McDoniel, Seth D Feltheimer, George S Stergiou, Thomas G Pickering, Joseph E Schwartz.   

Abstract

BACKGROUND: We evaluated the agreement between office blood pressure (OBP) measured by a mercury sphygmomanometer (Sphyg) and an automatic (Auto) device without any observers, and compared Auto and Sphyg OBP with ambulatory blood pressure (ABP) and home blood pressure (HBP).
METHODS: OBP was measured in 75 hypertensive patients at two sites using an automatic monitor without a doctor or a nurse present and by Sphyg during three clinic visits. Between visits, monitoring of ABP and HBP was also performed.
RESULTS: The mean Auto OBP was similar to that of Sphyg OBP and the values were closely correlated (intraclass correlation coefficient=0.84 for systolic OBP and 0.91 for diastolic OBP); however, the difference between Auto and Sphyg systolic OBP (1.6 ± 8.2 mmHg) varied by the first office visit, sex, and the site. Auto systolic OBP was lower than both systolic awake ABP (137.1 ± 14.7 mmHg) and HBP (139.2 ± 15.6 mmHg). Auto systolic OBP and Sphyg OBP were similarly correlated with systolic awake ABP (both r=0.59, P<0.001). The mean Auto diastolic OBP was similar to that of Sphyg OBP (81.1 ± 11.3 vs. 80.3 ± 13.3 mmHg, P=0.20, intraclass correlation coefficient=0.91), and diastolic awake ABP and HBP. Auto diastolic OBP and Sphyg OBP were related to diastolic awake ABP (both r>0.68, P<0.001). In multivariable analyses, neither OBP measure was a significantly stronger predictor of out-of-office blood pressure than the other.
CONCLUSION: Auto systolic OBP measured without a doctor or a nurse present was lower than systolic awake ABP and HBP. Auto and rigorously assessed Sphyg OBP had similar means and were similarly related to awake ABP. Auto OBP might be an advantageous alternative to Sphyg measurements in the usual clinic setting.

Entities:  

Mesh:

Year:  2012        PMID: 22425703      PMCID: PMC3348395          DOI: 10.1097/MBP.0b013e328352ade4

Source DB:  PubMed          Journal:  Blood Press Monit        ISSN: 1359-5237            Impact factor:   1.444


  15 in total

1.  Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research.

Authors:  Thomas G Pickering; John E Hall; Lawrence J Appel; Bonita E Falkner; John Graves; Martha N Hill; Daniel W Jones; Theodore Kurtz; Sheldon G Sheps; Edward J Roccella
Journal:  Hypertension       Date:  2004-12-20       Impact factor: 10.190

2.  Office blood pressure measurement with electronic devices: has the time come?

Authors:  George S Stergiou
Journal:  Am J Hypertens       Date:  2008-03       Impact factor: 2.689

3.  Validation of the Microlife WatchBP Home device for self home blood pressure measurement according to the International Protocol.

Authors:  George S Stergiou; Periklis P Giovas; Charilaos P Gkinos; John D Patouras
Journal:  Blood Press Monit       Date:  2007-06       Impact factor: 1.444

4.  Factors influencing white-coat effect.

Authors:  Efstathios D Manios; Eleni A Koroboki; Georgios K Tsivgoulis; Konstantinos M Spengos; Ioanna K Spiliopoulou; Fiona G Brodie; Konstantinos N Vemmos; Nikolaos A Zakopoulos
Journal:  Am J Hypertens       Date:  2008-01-03       Impact factor: 2.689

Review 5.  Measurement of blood pressure in the office: recognizing the problem and proposing the solution.

Authors:  Martin G Myers; Marshall Godwin; Martin Dawes; Alexander Kiss; Sheldon W Tobe; Janusz Kaczorowski
Journal:  Hypertension       Date:  2009-12-28       Impact factor: 10.190

Review 6.  What is the white-coat effect and how should it be measured?

Authors:  Thomas G Pickering; William Gerin; Amy R Schwartz
Journal:  Blood Press Monit       Date:  2002-12       Impact factor: 1.444

7.  Home or self blood pressure measurement? What is the correct term?

Authors:  George S Stergiou; Stamatis P Efstathiou; Christina V Alamara; Stilianos E Mastorantonakis; Leonidas G Roussias
Journal:  J Hypertens       Date:  2003-12       Impact factor: 4.844

8.  Anxiety and outcome expectations predict the white-coat effect.

Authors:  Juhee Jhalani; Tanya Goyal; Lynn Clemow; Joseph E Schwartz; Thomas G Pickering; William Gerin
Journal:  Blood Press Monit       Date:  2005-12       Impact factor: 1.444

9.  The impact of perceived hypertension status on anxiety and the white coat effect.

Authors:  Tanya M Spruill; Thomas G Pickering; Joseph E Schwartz; Elizabeth Mostofsky; Gbenga Ogedegbe; Lynn Clemow; William Gerin
Journal:  Ann Behav Med       Date:  2007-08

10.  The BpTRU automatic blood pressure monitor compared to 24 hour ambulatory blood pressure monitoring in the assessment of blood pressure in patients with hypertension.

Authors:  Linda Beckett; Marshall Godwin
Journal:  BMC Cardiovasc Disord       Date:  2005-06-28       Impact factor: 2.298

View more
  3 in total

1.  Comparing Automated Office Blood Pressure Readings With Other Methods of Blood Pressure Measurement for Identifying Patients With Possible Hypertension: A Systematic Review and Meta-analysis.

Authors:  Michael Roerecke; Janusz Kaczorowski; Martin G Myers
Journal:  JAMA Intern Med       Date:  2019-03-01       Impact factor: 44.409

Review 2.  Sources of inaccuracy in the measurement of adult patients' resting blood pressure in clinical settings: a systematic review.

Authors:  Noa Kallioinen; Andrew Hill; Mark S Horswill; Helen E Ward; Marcus O Watson
Journal:  J Hypertens       Date:  2017-03       Impact factor: 4.844

3.  The diagnostic value of supine blood pressure in hypertension.

Authors:  Paweł Krzesiński; Adam Stańczyk; Grzegorz Gielerak; Katarzyna Piotrowicz; Małgorzata Banak; Agnieszka Wójcik
Journal:  Arch Med Sci       Date:  2016-04-12       Impact factor: 3.318

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.