Literature DB >> 2242537

Strength-duration and probability of success curves for defibrillation with biphasic waveforms.

S A Feeser1, A S Tang, K M Kavanagh, D L Rollins, W M Smith, P D Wolf, R E Ideker.   

Abstract

Certain biphasic waveforms require less energy to defibrillate than do monophasic pulses of equal duration, although the mechanisms of this increased effectiveness remain unclear. This study used strength-duration and percent success curves for defibrillation with monophasic and biphasic truncated exponential waveforms to explore these mechanisms. In part 1, defibrillation thresholds were determined for both high- and low-tilt waveforms. The monophasic pulses tested ranged in duration from 1.0 to 20.0 msec, and the biphasic waveforms had first phases of either 3.5 or 7.0 msec and second phases ranging from 1.0 to 20.0 msec. In part 2, defibrillation percent success curves were constructed for 6.0 msec/6.0 msec biphasic waveforms with a constant phase-one amplitude and with phase-two amplitudes of approximately 21%, 62%, 94%, and 141% of phase one. This study shows that if the first phase of a biphasic waveform is held constant and the second phase is increased in either duration or amplitude, defibrillation efficacy first improves, then declines, and then again improves. For pulse durations of at least 14 msec, the second-phase defibrillation threshold voltage of a high-tilt biphasic waveform is higher than that of a monophasic pulse equal in duration to the biphasic second phase (p less than 0.05), indicating that the previously proposed hypothesis of stimulation by the second phase is not the sole mechanism of biphasic defibrillation. These facts indicate the importance of the degree of tilt for the defibrillation efficacy of biphasic waveforms and suggest at least two mechanisms exist for defibrillation with these waveforms, one that is more effective for smaller second phases and another that becomes more effective as the second phase is increased.

Mesh:

Year:  1990        PMID: 2242537     DOI: 10.1161/01.cir.82.6.2128

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  9 in total

1.  Analysis of electric field stimulation of single cardiac muscle cells.

Authors:  L Tung; J R Borderies
Journal:  Biophys J       Date:  1992-08       Impact factor: 4.033

2.  Optimal biphasic waveforms for internal defibrillation using a 60 muF capacitor.

Authors:  Yoshio Yamanouchi; Stéphane X Garrigue; Kent A Mowrey; Bruce L Wilkoff; Patrick J Tchou
Journal:  Exp Clin Cardiol       Date:  2002

3.  Mechanisms of cardiac cell excitation with premature monophasic and biphasic field stimuli: a model study.

Authors:  M G Fishler; E A Sobie; N V Thakor; L Tung
Journal:  Biophys J       Date:  1996-03       Impact factor: 4.033

4.  Chronaxie of defibrillation: a pathway toward further optimization of defibrillation waveform?

Authors:  Igor R Efimov
Journal:  J Cardiovasc Electrophysiol       Date:  2008-10-14

5.  [Mechanisms of electrical defibrillation].

Authors:  S Reek; R E Ideker
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03

Review 6.  Electrical Stimulation for Low-Energy Termination of Cardiac Arrhythmias: a Review.

Authors:  Skylar Buchan; Ronit Kar; Mathews John; Allison Post; Mehdi Razavi
Journal:  Cardiovasc Drugs Ther       Date:  2021-08-07       Impact factor: 3.727

Review 7.  Optimizing defibrillation waveforms for ICDs.

Authors:  Mark W Kroll; Charles D Swerdlow
Journal:  J Interv Card Electrophysiol       Date:  2007-06-01       Impact factor: 1.900

8.  High defibrillation threshold: the science, signs and solutions.

Authors:  Sony Jacob; Victorio Pidlaoan; Jaspreet Singh; Aditya Bharadwaj; Mehul B Patel; Antonio Carrillo
Journal:  Indian Pacing Electrophysiol J       Date:  2010-01-07

9.  Unusual case of late dislodgment of a superior vena cava coil.

Authors:  Taya V Glotzer; Monali Shah; Shashank Jain; John M Zimmerman
Journal:  HeartRhythm Case Rep       Date:  2018-06-11
  9 in total