Literature DB >> 22424581

Frequency and causes of stroke during or after transcatheter aortic valve implantation.

Rutger-Jan Nuis1, Nicolas M Van Mieghem, Carl J Schultz, Adriaan Moelker, Robert M van der Boon, Robert Jan van Geuns, Aad van der Lugt, Patrick W Serruys, Josep Rodés-Cabau, Ron T van Domburg, Peter J Koudstaal, Peter P de Jaegere.   

Abstract

Transcatheter aortic valve implantation (TAVI) is invariably associated with the risk of clinically manifest transient or irreversible neurologic impairment. We sought to investigate the incidence and causes of clinically manifest stroke during TAVI. A total of 214 consecutive patients underwent TAVI with the Medtronic-CoreValve System from November 2005 to September 2011 at our institution. Stroke was defined according to the Valve Academic Research Consortium recommendations. Its cause was established by analyzing the point of onset of symptoms, correlating the symptoms with the computed tomography-detected defects in the brain, and analyzing the presence of potential coexisting causes of stroke, in addition to a multivariate analysis to determine the independent predictors. Stroke occurred in 19 patients (9%) and was major in 10 (5%), minor in 3 (1%), and transient (transient ischemic attack) in 6 (3%). The onset of symptoms was early (≤24 hours) in 8 patients (42%) and delayed (>24 hours) in 11 (58%). Brain computed tomography showed a cortical infarct in 8 patients (42%), a lacunar infarct in 5 (26%), hemorrhage in 1 (5%), and no abnormalities in 5 (26%). Independent determinants of stroke were new-onset atrial fibrillation after TAVI (odds ratio 4.4, 95% confidence interval 1.2 to 15.6), and baseline aortic regurgitation grade III or greater (odds ratio 3.2, 95% confidence interval 1.1 to 9.3). In conclusion, the incidence of stroke was 9%, of which >1/2 occurred >24 hours after the procedure. New-onset atrial fibrillation was associated with a 4.4-fold increased risk of stroke. In conclusion, these findings indicate that improvements in postoperative care after TAVI are equally, if not more, important for the reduction of periprocedural stroke than preventive measures during the procedure.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22424581     DOI: 10.1016/j.amjcard.2012.01.389

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  32 in total

1.  Influence of continuously evolving transcatheter aortic valve implantation technology on cerebral oxygenation.

Authors:  Ward Eertmans; Cornelia Genbrugge; Tom Fret; Maud Beran; Kim Engelen; Herbert Gutermann; Margot Vander Laenen; Willem Boer; Bert Ferdinande; Frank Jans; Jo Dens; Cathy De Deyne
Journal:  J Clin Monit Comput       Date:  2016-12-26       Impact factor: 2.502

Review 2.  Incidence, predictors, origin and prevention of early and late neurological events after transcatheter aortic valve implantation (TAVI): a comprehensive review of current data.

Authors:  Philipp Kahlert; Fadi Al-Rashid; Björn Plicht; Heike Hildebrandt; Polykarpos Patsalis; Karim El Chilali; Daniel Wendt; Matthias Thielmann; Lars Bergmann; Eva Kottenberg; Marc Schlamann; Holger Eggebrecht; Heinz Jakob; Gerd Heusch; Thomas Konorza; Raimund Erbel
Journal:  J Thromb Thrombolysis       Date:  2013-05       Impact factor: 2.300

Review 3.  Current periprocedural anticoagulation in transcatheter aortic valve replacement: could bivalirudin be an option? Rationale and design of the BRAVO 2/3 studies.

Authors:  Ziad Sergie; Thierry Lefèvre; Eric Van Belle; Socrates Kakoulides; Usman Baber; Efthymios N Deliargyris; Roxana Mehran; Eberhard Grube; Jochen Reinöhl; George D Dangas
Journal:  J Thromb Thrombolysis       Date:  2013-05       Impact factor: 2.300

Review 4.  Antithrombotic therapy before, during and after transcatheter aortic valve replacement (TAVR).

Authors:  Abhishek Sharma; Sunny Goel; Carl J Lavie; Armin Arbab-Zadeh; Debabrata Mukherjee; Jason Lazar
Journal:  J Thromb Thrombolysis       Date:  2015-05       Impact factor: 2.300

5.  Antithrombotic treatment following transcatheter valve replacement: current considerations.

Authors:  Ioanna Koniari; Nicholas G Kounis; George Hahalis
Journal:  J Thorac Dis       Date:  2017-11       Impact factor: 2.895

6.  Development and Application of a Risk Prediction Model for In-Hospital Stroke After Transcatheter Aortic Valve Replacement: A Report From The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry.

Authors:  Vinod H Thourani; Sean M O'Brien; John J Kelly; David J Cohen; Eric D Peterson; Michael J Mack; David M Shahian; Frederick L Grover; John D Carroll; J Matthew Brennan; Jessica Forcillo; Suzanne V Arnold; Sreekanth Vemulapalli; Susan Fitzgerald; David R Holmes; Joseph E Bavaria; Fred H Edwards
Journal:  Ann Thorac Surg       Date:  2018-12-07       Impact factor: 4.330

Review 7.  Clinical implications of conduction abnormalities and arrhythmias after transcatheter aortic valve implantation.

Authors:  Robert M A van der Boon; Patrick Houthuizen; Rutger-Jan Nuis; Nicolas M van Mieghem; Frits Prinzen; Peter P T de Jaegere
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

Review 8.  Transcatheter aortic valve replacement: current application and future directions.

Authors:  Amir-Ali Fassa; Dominique Himbert; Alec Vahanian
Journal:  Curr Cardiol Rep       Date:  2013-04       Impact factor: 2.931

9.  Atrial Fibrillation Is Associated With Increased Mortality in Patients Undergoing Transcatheter Aortic Valve Replacement: Insights From the Placement of Aortic Transcatheter Valve (PARTNER) Trial.

Authors:  Angelo B Biviano; Tamim Nazif; Jose Dizon; Hasan Garan; Jessica Fleitman; Dua Hassan; Samir Kapadia; Vasilis Babaliaros; Ke Xu; Rupa Parvataneni; Josep Rodes-Cabau; Wilson Y Szeto; William F Fearon; Danny Dvir; Todd Dewey; Mathew Williams; Michael J Mack; John G Webb; D Craig Miller; Craig R Smith; Martin B Leon; Susheel Kodali
Journal:  Circ Cardiovasc Interv       Date:  2016-01       Impact factor: 6.546

10.  Transcatheter Aortic Valve Replacement and Left Atrial Appendage Occlusion - A Stitch in Time?

Authors:  Sameer Gafoor; Luisa Heuer; Jennifer Franke; Stefan Bertog; Laura Vaskelyte; Ilona Hofmann; Horst Sievert
Journal:  Interv Cardiol       Date:  2014-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.