Literature DB >> 22423058

Transcranial Doppler-detected cerebral embolic load during transcatheter aortic valve implantation.

Gabor Erdoes1, Reto Basciani, Christoph Huber, Stefan Stortecky, Peter Wenaweser, Stephan Windecker, Thierry Carrel, Balthasar Eberle.   

Abstract

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique.
METHODS: Transcranial Doppler (TCD) ultrasound recordings of 44 patients undergoing TAVI (age 78 ± 6 years; logistic EuroSCORE 28 ± 15%; transfemoral access, n = 32; transapical access, n = 12; SE, n = 27; BE, n = 17) were analysed for HITS during the following intervals: (i) instrumentation prior to valvuloplasty, (ii) balloon valvuloplasty, (iii) prosthesis deployment (DP) and (iv) post-implantation (PI) including any re-dilatation episodes. The total procedural load of HITS and HITS frequency in procedural intervals were compared between different access routes and DP techniques. Periprocedural neurocognitive impairment was assessed clinically and by the confusion assessment method (CAM) prior to TAVI and on post-procedural days 1 and 4-6.
RESULTS: TCD recordings demonstrated the occurrence of HITS in all patients. DP was associated with the highest load of HITS. Access route did not significantly influence the total burden of periprocedural HITS. During procedures using the SE type, a slightly larger total load of HITS was observed than with the BE type (P = 0.024). This was mainly due to more HITS during the DP (P = 0.027) and the PI interval (P = 0.002). No incidence of delirium was detected by CAM ratings. Two patients suffered a new onset of stroke within the 2 weeks following the procedure. In-hospital death and 30-day mortality were 0/44.
CONCLUSIONS: HITS are observed during all procedural intervals in TAVI. The embolic events appear to peak during DP. In our series, the overall cerebral embolic load did not differ between the transfemoral and the transapical access route. TCD monitoring in TAVI is useful to identify periods and manipulations associated with an increased cerebral embolic load and may help to further enhance the safety of this procedure.

Entities:  

Mesh:

Year:  2011        PMID: 22423058     DOI: 10.1093/ejcts/ezr068

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  18 in total

1.  Etiologic stroke subtypes: updated definition and efficient workup strategies.

Authors:  Prachi Mehndiratta; Sherita Chapman Smith; Bradford B Worrall
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-01

Review 2.  Cerebral embolic protection devices during transcatheter aortic valve implantation: clinical versus silent embolism.

Authors:  Luis Nombela-Franco; German Armijo; Gabriela Tirado-Conte
Journal:  J Thorac Dis       Date:  2018-11       Impact factor: 2.895

3.  Influence of continuously evolving transcatheter aortic valve implantation technology on cerebral oxygenation.

Authors:  Ward Eertmans; Cornelia Genbrugge; Tom Fret; Maud Beran; Kim Engelen; Herbert Gutermann; Margot Vander Laenen; Willem Boer; Bert Ferdinande; Frank Jans; Jo Dens; Cathy De Deyne
Journal:  J Clin Monit Comput       Date:  2016-12-26       Impact factor: 2.502

Review 4.  Incidence, predictors, origin and prevention of early and late neurological events after transcatheter aortic valve implantation (TAVI): a comprehensive review of current data.

Authors:  Philipp Kahlert; Fadi Al-Rashid; Björn Plicht; Heike Hildebrandt; Polykarpos Patsalis; Karim El Chilali; Daniel Wendt; Matthias Thielmann; Lars Bergmann; Eva Kottenberg; Marc Schlamann; Holger Eggebrecht; Heinz Jakob; Gerd Heusch; Thomas Konorza; Raimund Erbel
Journal:  J Thromb Thrombolysis       Date:  2013-05       Impact factor: 2.300

5.  Predilatation Prior to Transcatheter Aortic Valve Implantation: Is it Still a Prerequisite?

Authors:  Matteo Pagnesi; Luca Baldetti; Paolo Del Sole; Antonio Mangieri; Marco B Ancona; Damiano Regazzoli; Nicola Buzzatti; Francesco Giannini; Antonio Colombo; Azeem Latib
Journal:  Interv Cardiol       Date:  2017-09

6.  Balloon- or Self-Expandable TAVI: Clinical Equipoise?

Authors:  John Jose; Gert Richardt; Mohamed Abdel-Wahab
Journal:  Interv Cardiol       Date:  2015-05

7.  Silent ischemic brain lesions after transcatheter aortic valve replacement: lesion distribution and predictors.

Authors:  Mariam Samim; Jeroen Hendrikse; H Bart van der Worp; Pierfrancesco Agostoni; Freek Nijhoff; Pieter A Doevendans; Pieter R Stella
Journal:  Clin Res Cardiol       Date:  2015-01-18       Impact factor: 5.460

Review 8.  Access Options for Transcatheter Aortic Valve Replacement in Patients with Unfavorable Aortoiliofemoral Anatomy.

Authors:  Jayendrakumar S Patel; Amar Krishnaswamy; Lars G Svensson; E Murat Tuzcu; Stephanie Mick; Samir R Kapadia
Journal:  Curr Cardiol Rep       Date:  2016-11       Impact factor: 2.931

9.  Transcatheter Aortic Valve Replacement and Left Atrial Appendage Occlusion - A Stitch in Time?

Authors:  Sameer Gafoor; Luisa Heuer; Jennifer Franke; Stefan Bertog; Laura Vaskelyte; Ilona Hofmann; Horst Sievert
Journal:  Interv Cardiol       Date:  2014-04

10.  Managing Stroke During Transcatheter Aortic Valve Replacement.

Authors:  Florian Hecker; Mani Arsalan; Thomas Walther
Journal:  Interv Cardiol       Date:  2017-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.