Literature DB >> 22421177

Temporal enhancement of 3D echocardiography by frame reordering.

Douglas P Perrin1, Nikolay V Vasilyev, Gerald R Marx, Pedro J del Nido.   

Abstract

We describe a method to increase the frame rate for 3-dimensional ultrasound sequences of periodically moving cardiac structures by reordering the acquired volume series. The frame rate is especially important in studying intracardiac structures such as valve leaflet motion in which valve closing times are on the order of milliseconds. Current commercially available systems for volumetric ultrasound imaging are limited to approximately 10 to 20 volumes per second. Although this frame rate is sufficient for real-time observation of basic cardiac morphology, understanding cardiac dynamics requires faster frame rates. The presented work achieves higher frame rates by sampling over several beats and using a simultaneous electrocardiography signal to accurately place the frame within the cardiac cycle. The proposed method relies on periodicity of the heart motion and that within the temporal regions of highest velocity, the structural motions of interest have the lowest beat-to-beat variability.
Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22421177      PMCID: PMC3312787          DOI: 10.1016/j.jcmg.2011.10.006

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  4 in total

1.  New three-dimensional echocardiographic system using digital radiofrequency data--visualization and quantitative analysis of aortic valve dynamics with high resolution: methods, feasibility, and initial clinical experience.

Authors:  Michael Handke; Cosima Jahnke; Gudrun Heinrichs; Jörg Schlegel; Clemens Vos; Daniel Schmitt; Christoph Bode; Annette Geibel
Journal:  Circulation       Date:  2003-06-02       Impact factor: 29.690

2.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

3.  Characterization of degenerative mitral valve disease using morphologic analysis of real-time three-dimensional echocardiographic images: objective insight into complexity and planning of mitral valve repair.

Authors:  Sonal Chandra; Ivan S Salgo; Lissa Sugeng; Lynn Weinert; Wendy Tsang; Masaaki Takeuchi; Kirk T Spencer; Anne O'Connor; Michael Cardinale; Scott Settlemier; Victor Mor-Avi; Roberto M Lang
Journal:  Circ Cardiovasc Imaging       Date:  2010-09-30       Impact factor: 7.792

4.  Usefulness of intra-operative epicardial three-dimensional echocardiography to guide aortic valve repair in children.

Authors:  Vladimiro L Vida; Renè Hoehn; Luis Alesandro Larrazabal; Kimberlee Gauvreau; Gerald R Marx; Pedro J del Nido
Journal:  Am J Cardiol       Date:  2009-01-24       Impact factor: 2.778

  4 in total
  5 in total

1.  Multicenter study comparing shunt type in the norwood procedure for single-ventricle lesions: three-dimensional echocardiographic analysis.

Authors:  Gerald R Marx; Girish Shirali; Jami C Levine; Lin T Guey; James F Cnota; Jeanne M Baffa; William L Border; Steve Colan; Gregory Ensing; Mark K Friedberg; David J Goldberg; Salim F Idriss; J Blaine John; Wyman W Lai; Minmin Lu; Shaji C Menon; Richard G Ohye; David Saudek; Pierre C Wong; Gail D Pearson
Journal:  Circ Cardiovasc Imaging       Date:  2013-10-04       Impact factor: 7.792

2.  Output-Sensitive Filtering of Streaming Volume Data.

Authors:  Veronika Solteszova; Åsmund Birkeland; Sergej Stoppel; Ivan Viola; Stefan Bruckner
Journal:  Comput Graph Forum       Date:  2016-03-01       Impact factor: 2.078

3.  3D ultrafast ultrasound imaging in vivo.

Authors:  Jean Provost; Clement Papadacci; Juan Esteban Arango; Marion Imbault; Mathias Fink; Jean-Luc Gennisson; Mickael Tanter; Mathieu Pernot
Journal:  Phys Med Biol       Date:  2014-09-10       Impact factor: 3.609

4.  Quantification of right ventricular volume in dogs: a comparative study between three-dimensional echocardiography and computed tomography with the reference method magnetic resonance imaging.

Authors:  Anne K Sieslack; Peter Dziallas; Ingo Nolte; Patrick Wefstaedt; Stephan O Hungerbühler
Journal:  BMC Vet Res       Date:  2014-10-12       Impact factor: 2.741

5.  Quantification of left ventricular volumes and function in anesthetized beagles using real-time three-dimensional echocardiography: 4D-TomTec™ analysis versus 4D-AutLVQ™ analysis in comparison with cardiac magnetic resonance imaging.

Authors:  Judith Eskofier; Patrick Wefstaedt; Martin Beyerbach; Ingo Nolte; Stephan O Hungerbühler
Journal:  BMC Vet Res       Date:  2015-10-12       Impact factor: 2.741

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.