Guidance on the use of handheld survey meters for radiological triage: time-dependent detector count rates corresponding to 50, 250, and 500 mSV effective dose for adult males and adult females.

Wesley E Bolch1, Jorge L Hurtado, Choonsik Lee, Ryan Manger, Eric Burgett, Nolan Hertel, William Dickerson.   

Abstract

In June 2006, the Radiation Studies Branch of the Centers for Disease Control and Prevention held a workshop to explore rapid methods of facilitating radiological triage of large numbers of potentially contaminated individuals following detonation of a radiological dispersal device. Two options were discussed. The first was the use of traditional gamma cameras in nuclear medicine departments operated as makeshift wholebody counters. Guidance on this approach is currently available from the CDC. This approach would be feasible if a manageable number of individuals were involved, transportation to the relevant hospitals was quickly provided, and the medical staff at each facility had been previously trained in this non-traditional use of their radiopharmaceutical imaging devices. If, however,substantially larger numbers of individuals (100’s to 1,000’s) needed radiological screening, other options must be given to first responders, first receivers, and health physicists providing medical management. In this study, the second option of the workshop was investigated--the use of commercially available portable survey meters (either NaI or GM based) for assessing potential ranges of effective dose (< 50, 50-250, 250-500,and >500 mSv). Two hybrid computational phantoms were used to model an adult male and an adult female subject internally contaminated with 241Am, 60Cs, 137Cs, 131I, or 192Ir following an acute inhalation or ingestion intake. As a function of time following the exposure, the net count rates corresponding to committed effective doses of 50, 250, and 500 mSv were estimated via Monte Carlo radiation transport simulation for each of four different detector types, positions, and screening distances.Measured net count rates can be compared to these values, and an assignment of one of four possible effective dose ranges could be made. The method implicitly assumes that all external contamination has been removed prior to screening and that the measurements be conducted in a low background, and possibly mobile, facility positioned at the triage location. Net count rate data are provided in both tabular and graphical format within a series of eight handbooks available at the CDC website (http://www.bt.cdc.gov/radiation/clinicians/evaluation).

Entities:  

Mesh:

Year:  2012        PMID: 22420020      PMCID: PMC3909989          DOI: 10.1097/hp.0b013e3182351660

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  6 in total

1.  Realistic radiological dispersal device hazard boundaries and ramifications for early consequence management decisions.

Authors:  Frederick T Harper; Stephen V Musolino; William B Wente
Journal:  Health Phys       Date:  2007-07       Impact factor: 1.316

2.  NURBS-based 3-D anthropomorphic computational phantoms for radiation dosimetry applications.

Authors:  Choonsik Lee; Choonik Lee; Daniel Lodwick; Wesley E Bolch
Journal:  Radiat Prot Dosimetry       Date:  2007-06-13       Impact factor: 0.972

Review 3.  Age-dependent doses to members of the public from intake of radionuclides: Part 5. Compilation of ingestion and inhalation dose coefficients.

Authors: 
Journal:  Ann ICRP       Date:  1996

Review 4.  Human respiratory tract model for radiological protection. A report of a Task Group of the International Commission on Radiological Protection.

Authors: 
Journal:  Ann ICRP       Date:  1994

5.  Hybrid computational phantoms of the 15-year male and female adolescent: applications to CT organ dosimetry for patients of variable morphometry.

Authors:  Choonsik Lee; Daniel Lodwick; Jonathan L Williams; Wesley E Bolch
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

6.  Guidance on the use of handheld survey meters for radiological triage: time-dependent detector count rates corresponding to 50, 250, and 500 mSV effective dose for adult males and adult females.

Authors:  Wesley E Bolch; Jorge L Hurtado; Choonsik Lee; Ryan Manger; Eric Burgett; Nolan Hertel; William Dickerson
Journal:  Health Phys       Date:  2012-03       Impact factor: 1.316

  6 in total
  3 in total

1.  Hybrid computational phantoms representing the reference adult male and adult female: construction and applications for retrospective dosimetry.

Authors:  Jorge L Hurtado; Choonsik Lee; Daniel Lodwick; Timothy Goede; Jonathan L Williams; Wesley E Bolch
Journal:  Health Phys       Date:  2012-03       Impact factor: 1.316

2.  Use of Transportable Radiation Detection Instruments to Assess Internal Contamination from Intakes of Radionuclides Part II: Calibration Factors and ICAT Computer Program.

Authors:  Robert Anigstein; Richard H Olsher; Donald A Loomis; Armin Ansari
Journal:  Health Phys       Date:  2016-12       Impact factor: 1.316

3.  Guidance on the use of handheld survey meters for radiological triage: time-dependent detector count rates corresponding to 50, 250, and 500 mSV effective dose for adult males and adult females.

Authors:  Wesley E Bolch; Jorge L Hurtado; Choonsik Lee; Ryan Manger; Eric Burgett; Nolan Hertel; William Dickerson
Journal:  Health Phys       Date:  2012-03       Impact factor: 1.316

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.