Literature DB >> 22417836

A new highly specific buprenorphine immunoassay for monitoring buprenorphine compliance and abuse.

Stacy E F Melanson1, Marion L Snyder, Petr Jarolim, James G Flood.   

Abstract

Urine buprenorphine screening is utilized to assess buprenorphine compliance and to detect illicit use. Robust screening assays should be specific for buprenorphine without cross-reactivity with other opioids, which are frequently present in patients treated for opioid addiction and chronic pain. We evaluated the new Lin-Zhi urine buprenorphine enzyme immunoassay (EIA) as a potentially more specific alternative to the Microgenics cloned enzyme donor immunoassay (CEDIA) by using 149 urines originating from patients treated for chronic pain and opioid addiction. The EIA methodology offered specific detection of buprenorphine use (100%) (106/106) and provided superior overall agreement with liquid chromatography-tandem mass spectrometry, 95% (142/149) and 91% (135/149) using 5 ng/mL (EIA[5]) and 10 ng/mL (EIA[10]) cutoffs, respectively, compared to CEDIA, 79% (117/149). CEDIA generated 27 false positives, most of which were observed in patients positive for other opioids, providing an overall specificity of 75% (79/106). CEDIA also demonstrated interference from structurally unrelated drugs, chloroquine and hydroxychloroquine. CEDIA and EIA[5] yielded similar sensitivities, both detecting 96% (22/23) of positive samples from patients prescribed buprenorphine, and 88% (38/43) and 81% (35/43), respectively, of all positive samples (illicit and prescribed users). The EIA methodology provides highly specific and sensitive detection of buprenorphine use, without the potential for opioid cross-reactivity.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22417836     DOI: 10.1093/jat/bks003

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  4 in total

Review 1.  Laboratory testing for prescription opioids.

Authors:  Michael C Milone
Journal:  J Med Toxicol       Date:  2012-12

2.  Cross-reactivity of the CEDIA buprenorphine assay in drugs-of-abuse screening: influence of dose and metabolites of opioids.

Authors:  Jon Andsnes Berg; Jan Schjøtt; Kjell O Fossan; Bettina Riedel
Journal:  Subst Abuse Rehabil       Date:  2015-10-28

3.  Data on hydroxychloroquine interference with urine laboratory testing.

Authors:  Jennie M Kingery; Joshua B Radke; Jon Maakestad; Matthew D Krasowski
Journal:  Data Brief       Date:  2019-11-08

4.  Diagnostic pitfalls and laboratory test interference after hydroxychloroquine intoxication: A case report.

Authors:  Joshua B Radke; Jennie M Kingery; Jon Maakestad; Matthew D Krasowski
Journal:  Toxicol Rep       Date:  2019-10-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.