Literature DB >> 22416182

Evaluation of acoustic radiation force impulse imaging for determination of liver stiffness using transient elastography as a reference.

Gerald Kircheis1, Abdurrahman Sagir, Christoph Vogt, Stephan Vom Dahl, Ralf Kubitz, Dieter Häussinger.   

Abstract

AIM: To evaluate cut-off values and performance of acoustic radiation force impulse imaging (ARFI) using transient elastography [FibroScan© (FS)] as a reference.
METHODS: Six hundred and six patients were enrolled in this study. All patients underwent liver stiffness measurement with FS (FS-LS) and ARFI (with shear wave velocity quantification; ARFI-SWV) and the performance of ARFI in comparison to FS was determined. Sixty-eight patients underwent liver biopsy.
RESULTS: Significantly higher success rates for the determination of liver stiffness were found using ARFI as compared to FS [604/606 (99.7%) vs. 482/606 (79.5%), P < 0.001]. ARFI-SWV correlated significantly with FS-LS (r = 0.920, P < 0.001). ARFI-SWV increased significantly with the stage of fibrosis (1.09 ± 0.13 m/s for patients with no significant fibrosis (FS-LS < 7.6 kPa); 1.46 ± 0.27 m/s for patients with significant liver fibrosis (7.6 < FS-LS ≤ 13.0 kPa); and 2.55 ± 0.77 m/s for patients with liver cirrhosis (FS-LS > 13.0 kPa)). ARFI-SWV cut-off values were identified for no significant fibrosis (1.29 m/s; sensitivity 91.4% and specificity 92.6%) and for liver cirrhosis (1.60 m/s; sensitivity 92.3% and specificity 96.5%). The optimal cut-off value for predicting liver fibrosis (F ≥ 2) was 1.32 m/s (sensitivity 87.0% and specificity 80.0%) and for liver cirrhosis (F4) 1.62 m/s (sensitivity 100% and specificity 85.7%), for patients who underwent liver biopsy. An excellent inter-and intraobserver reproducibility was observed for ARFI-SWV determinations.
CONCLUSION: An ARFI-SWV cut-off value of 1.29 m/s seems to be optimal for patients with no significant liver fibrosis and 1.60 m/s for patients with liver cirrhosis.

Entities:  

Keywords:  Acoustic radiation force impulse imaging; Elastography; Fibroscan; Liver

Mesh:

Year:  2012        PMID: 22416182      PMCID: PMC3296981          DOI: 10.3748/wjg.v18.i10.1077

Source DB:  PubMed          Journal:  World J Gastroenterol        ISSN: 1007-9327            Impact factor:   5.742


  41 in total

1.  Shear-wave generation using acoustic radiation force: in vivo and ex vivo results.

Authors:  Kathryn Nightingale; Stephen McAleavey; Gregg Trahey
Journal:  Ultrasound Med Biol       Date:  2003-12       Impact factor: 2.998

2.  Acoustic radiation force impulse imaging of in vivo vastus medialis muscle under varying isometric load.

Authors:  Kathryn Nightingale; Roger Nightingale; Deborah Stutz; Gregg Trahey
Journal:  Ultrason Imaging       Date:  2002-04       Impact factor: 1.578

3.  Observations of tissue response to acoustic radiation force: opportunities for imaging.

Authors:  Kathryn Nightingale; Rex Bentley; Gregg Trahey
Journal:  Ultrason Imaging       Date:  2002-07       Impact factor: 1.578

4.  Shear properties of mammalian tissues at low megahertz frequencies.

Authors:  L A Frizzell; E L Carstensen
Journal:  J Acoust Soc Am       Date:  1976-12       Impact factor: 1.840

5.  Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection.

Authors:  Arie Regev; Mariana Berho; Lennox J Jeffers; Clara Milikowski; Enrique G Molina; Nikolaos T Pyrsopoulos; Zheng-Zhou Feng; K Rajender Reddy; Eugene R Schiff
Journal:  Am J Gastroenterol       Date:  2002-10       Impact factor: 10.864

6.  Noninvasive evaluation of hepatic fibrosis using acoustic radiation force-based shear stiffness in patients with nonalcoholic fatty liver disease.

Authors:  Mark L Palmeri; Michael H Wang; Ned C Rouze; Manal F Abdelmalek; Cynthia D Guy; Barry Moser; Anna Mae Diehl; Kathryn R Nightingale
Journal:  J Hepatol       Date:  2011-01-21       Impact factor: 25.083

7.  Practices of liver biopsy in France: results of a prospective nationwide survey. For the Group of Epidemiology of the French Association for the Study of the Liver (AFEF).

Authors:  J F Cadranel; P Rufat; F Degos
Journal:  Hepatology       Date:  2000-09       Impact factor: 17.425

8.  Sampling variability on percutaneous liver biopsy.

Authors:  W Abdi; J C Millan; E Mezey
Journal:  Arch Intern Med       Date:  1979-06

9.  Transient elastography: a new noninvasive method for assessment of hepatic fibrosis.

Authors:  Laurent Sandrin; Bertrand Fourquet; Jean-Michel Hasquenoph; Sylvain Yon; Céline Fournier; Frédéric Mal; Christos Christidis; Marianne Ziol; Bruno Poulet; Farad Kazemi; Michel Beaugrand; Robert Palau
Journal:  Ultrasound Med Biol       Date:  2003-12       Impact factor: 2.998

10.  Sampling variability of liver fibrosis in chronic hepatitis C.

Authors:  Pierre Bedossa; Delphine Dargère; Valerie Paradis
Journal:  Hepatology       Date:  2003-12       Impact factor: 17.425

View more
  24 in total

Review 1.  Liver elastography, comments on EFSUMB elastography guidelines 2013.

Authors:  Xin-Wu Cui; Mireen Friedrich-Rust; Chiara De Molo; Andre Ignee; Dagmar Schreiber-Dietrich; Christoph F Dietrich
Journal:  World J Gastroenterol       Date:  2013-10-14       Impact factor: 5.742

2.  Screening for non-alcoholic fatty liver disease in children and adolescents with type 1 diabetes mellitus: a cross-sectional analysis.

Authors:  Sebastian Kummer; Dirk Klee; Gerald Kircheis; Michael Friedt; Joerg Schaper; Dieter Häussinger; Ertan Mayatepek; Thomas Meissner
Journal:  Eur J Pediatr       Date:  2017-02-17       Impact factor: 3.183

3.  Effect of depth on shear-wave elastography estimated in the internal and external cervical os during pregnancy.

Authors:  Edgar Hernandez-Andrade; Alma Aurioles-Garibay; Maynor Garcia; Steven J Korzeniewski; Alyse G Schwartz; Hyunyoung Ahn; Alicia Martinez-Varea; Lami Yeo; Tinnakorn Chaiworapongsa; Sonia S Hassan; Roberto Romero
Journal:  J Perinat Med       Date:  2014-09       Impact factor: 1.901

4.  The value of ultrasound elastography-guided fine-needle aspiration biopsy of thyroid nodules in reducing nondiagnostic results.

Authors:  Duzgun Yildirim; Bengi Gurses; Berk Gurpinar; Baki Ekci; Bulent Colakoglu; Mutlu Sahin; Ahmet Kaur
Journal:  J Med Ultrason (2001)       Date:  2012-11-14       Impact factor: 1.314

5.  Acoustic Radiation Force-Induced Creep-Recovery (ARFICR): A Noninvasive Method to Characterize Tissue Viscoelasticity.

Authors:  Carolina Amador Carrascal; Shigao Chen; Matthew W Urban; James F Greenleaf
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-01       Impact factor: 2.725

6.  Prediction of development of hepatocellular carcinoma using a new scoring system involving virtual touch quantification in patients with chronic liver diseases.

Authors:  Tomoko Aoki; Hiroko Iijima; Toshifumi Tada; Takashi Kumada; Takashi Nishimura; Chikage Nakano; Kyohei Kishino; Yoshihiro Shimono; Kazunori Yoh; Ryo Takata; Akio Ishii; Tomoyuki Takashima; Yoshiyuki Sakai; Nobuhiro Aizawa; Hiroki Nishikawa; Naoto Ikeda; Yoshinori Iwata; Hirayuki Enomoto; Seiichi Hirota; Jiro Fujimoto; Shuhei Nishiguchi
Journal:  J Gastroenterol       Date:  2016-06-15       Impact factor: 7.527

7.  Strain wave elastography for evaluation of renal parenchyma in chronic kidney disease.

Authors:  M S Menzilcioglu; M Duymus; S Citil; S Avcu; G Gungor; T Sahin; S N Boysan; O Altunoren; A Sarica
Journal:  Br J Radiol       Date:  2015-03-25       Impact factor: 3.039

Review 8.  Non-invasive diagnosis of liver fibrosis in chronic hepatitis C.

Authors:  Leonardo de Lucca Schiavon; Janaína Luz Narciso-Schiavon; Roberto José de Carvalho-Filho
Journal:  World J Gastroenterol       Date:  2014-03-21       Impact factor: 5.742

Review 9.  Non-invasive diagnosis of hepatitis B virus-related cirrhosis.

Authors:  Sangheun Lee; Do Young Kim
Journal:  World J Gastroenterol       Date:  2014-01-14       Impact factor: 5.742

10.  Evaluating the feasibility of acoustic radiation force impulse shear wave elasticity imaging of the uterine cervix with an intracavity array: a simulation study.

Authors:  Mark L Palmeri; Helen Feltovich; Andrew D Homyk; Lindsey C Carlson; Timothy J Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-10       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.