Literature DB >> 22414838

Canal shaping with WaveOne Primary reciprocating files and ProTaper system: a comparative study.

Elio Berutti1, Giorgio Chiandussi, Davide Salvatore Paolino, Nicola Scotti, Giuseppe Cantatore, Arnaldo Castellucci, Damiano Pasqualini.   

Abstract

INTRODUCTION: This study compared the canal curvature and axis modification after instrumentation with WaveOne Primary reciprocating files (Dentsply Maillefer, Ballaigues, Switzerland) and nickel-titanium (NiTi) rotary ProTaper (Dentsply Maillefer).
METHODS: Thirty ISO 15, 0.02 taper, Endo Training Blocks (Dentsply Maillefer) were used. In all specimens, the glide path was achieved with PathFile 1, 2, and 3 (Dentsply Maillefer) at the working length (WL). Specimens were then assigned to 1 of 2 groups for shaping: specimens in group 1 were shaped with ProTaper S1-S2-F1-F2 at the WL and specimens in group 2 were shaped with WaveOne Primary reciprocating files at the WL. Pre- and postinstrumentation digital images were superimposed and processed with Matlab r2010b (The MathWorks Inc, Natick, MA) software to analyze the curvature-radius ratio (CRr) and the relative axis error (rAe), representing canal curvature modification. Data were analyzed with one-way balanced analyses of variance at 2 levels (P < .05).
RESULTS: The instrument factor was extremely significant for both the CRr parameter (F(1) = 9.59, P = .004) and the rAe parameter (F(1) = 13.55, P = .001).
CONCLUSIONS: Canal modifications are reduced when the new WaveOne NiTi single-file system is used. Copyright Â
© 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22414838     DOI: 10.1016/j.joen.2011.12.040

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  43 in total

1.  ProTaper and WaveOne systems three-dimensional comparison of device parameters after the shaping technique. A micro-CT study on simulated root canals.

Authors:  Mario Dioguardi; Giuseppe Troiano; Luigi Laino; Lucio Lo Russo; Giovanni Giannatempo; Floriana Lauritano; Marco Cicciù; Lorenzo Lo Muzio
Journal:  Int J Clin Exp Med       Date:  2015-10-15

2.  Metallurgical analysis and fatigue resistance of WaveOne and ProTaper nickel-titanium instruments.

Authors:  Chiara Pirani; Oddone Ruggeri; Pier Paolo Cirulli; Gian Andrea Pelliccioni; Maria Giovanna Gandolfi; Carlo Prati
Journal:  Odontology       Date:  2013-04-09       Impact factor: 2.634

3.  Apically extruded dentin debris by reciprocating single-file and multi-file rotary system.

Authors:  Gustavo De-Deus; Aline Neves; Emmanuel João Silva; Thais Accorsi Mendonça; Caroline Lourenço; Camila Calixto; Edson Jorge Moreira Lima
Journal:  Clin Oral Investig       Date:  2014-06-21       Impact factor: 3.573

4.  A Comparative Study of Shaping Ability of four Rotary Systems.

Authors:  Jorge Rubio; José Ignacio Zarzosa; Antonio Pallarés
Journal:  Acta Stomatol Croat       Date:  2015-12

5.  Shaping Ability of Reciproc Blue Versus One Curve in Curved Canal: An In-Vitro Study.

Authors:  Mohammad Daher Altufayli; Basem Salim; Imad Katbeh; Razan Merei; Zarina Mamasaidova
Journal:  Cureus       Date:  2022-04-22

6.  Canal shaping with WaveOne reciprocating files: influence of operator experience on instrument breakage and canal preparation time.

Authors:  Luigi Generali; Elena Righi; Maria Vittoria Todesca; Ugo Consolo
Journal:  Odontology       Date:  2013-06-28       Impact factor: 2.634

7.  Shaping Ability of Reciproc, UnicOne, and Protaper Universal in Simulated Root Canals.

Authors:  Etevaldo Matos Maia Filho; Cláudia de Castro Rizzi; Matheus Bandeca Coelho; Sara Freitas Santos; Luzia Mayanne Oliveira Costa; Ceci Nunes Carvalho; Rudys Rodolfo de Jesus Tavarez; Janir Alves Soares
Journal:  ScientificWorldJournal       Date:  2015-04-09

8.  Apical extrusion of debris and irrigants using ProTaper hand, M-two rotary and WaveOne single file reciprocating system: An ex vivo study.

Authors:  Abhishek Singh; Doraiswamy Arunagiri; Shankarappa Pushpa; Asheesh Sawhny; Abhinav Misra; Kirti Khetan
Journal:  J Conserv Dent       Date:  2015 Sep-Oct

9.  Shaping Ability of 5(th) Generation Ni-Ti Rotary Systems for Root Canal Preparation in Curved Root Canals using CBCT: An In Vitro Study.

Authors:  Jain Deepak; Medha Ashish; Neelam Patil; Nilam Kadam; Vandana Yadav; Harshal Jagdale
Journal:  J Int Oral Health       Date:  2015

10.  Alterations of the Danger Zone after Preparation of Curved Root Canals Using WaveOne with Reverse Rotation or Reciprocation Movements.

Authors:  Yazdan Shantiaee; Omid Dianat; Payam Paymanpour; Golnaz Nahvi; Mohammad Ali Ketabi; Golbarg Kolahi Ahari
Journal:  Iran Endod J       Date:  2015-07-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.