Evaluation of saliva collection devices for the analysis of proteins.

Eleni Topkas1, Patricia Keith, Goce Dimeski, Justin Cooper-White, Chamindie Punyadeera.   

Abstract

BACKGROUND: Human saliva mirrors the body's health and can be collected non-invasively, does not require specialized skills and is suitable for large population based screening programs. The aims were twofold: to evaluate the suitability of commercially available saliva collection devices for quantifying proteins present in saliva and to provide levels for C-reactive protein (CRP), myoglobin, and immunoglobin E (IgE) in saliva of healthy individuals as a baseline for future studies.
METHODS: Saliva was collected from healthy volunteers (n=17, ages 18-33years). The following collection methods were evaluated: drool; Salimetrics® Oral Swab (SOS); Salivette® Cotton and Synthetic (Sarstedt) and Greiner Bio-One Saliva Collection System (GBO SCS®). We used AlphaLISA® assays to measure CRP, IgE and myoglobin levels in human saliva.
RESULTS: Significant (p<0.05) differences in the salivary flow rates were observed based on the method of collection, i.e. salivary flow rates were significantly lower (p<0.05) in unstimulated saliva (i.e. drool and SOS), when compared with mechanically stimulated methods (p<0.05) (Salivette® Cotton and Synthetic) and acid stimulated method (p<0.05) (SCS®). Saliva collected using SOS yielded significantly (p<0.05) lower concentrations of myoglobin and CRP, whilst, saliva collected using the Salivette® Cotton and Synthetic swab yielded significantly (p<0.05) lower myoglobin and IgE concentrations respectively.
CONCLUSIONS: The results demonstrated significantly relevant differences in analyte levels based on the collection method. Significant differences in the salivary flow rates were also observed depending on the saliva collection method. The data provide preliminary baseline values for salivary CRP, myoglobin, and IgE levels in healthy participants and based on the collection method.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22405932     DOI: 10.1016/j.cca.2012.02.020

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  38 in total

1.  Comparison of salivary and calculated free cortisol levels during low and standard dose of ACTH stimulation tests in healthy volunteers.

Authors:  Gulsah Elbuken; Fatih Tanriverdi; Zuleyha Karaca; Mustafa Kula; Selma Gokahmetoglu; Kursad Unluhizarci; Fahrettin Kelestimur
Journal:  Endocrine       Date:  2014-08-13       Impact factor: 3.633

2.  Role of Reactive Oxygen Species and Advanced Glycation End Products in the Malfunctioning of Dental Implants.

Authors:  M Guo; L Liu; J Zhang; M Liu
Journal:  West Indian Med J       Date:  2015-04-29       Impact factor: 0.171

3.  Comparing methods to collect saliva from children to analyze cytokines related to allergic inflammation.

Authors:  Girish Hiremath; Anthony Olive; Samir Shah; Carla M Davis; Robert J Shulman; Sridevi Devaraj
Journal:  Ann Allergy Asthma Immunol       Date:  2014-10-14       Impact factor: 6.347

4.  RNAPro•SAL: a device for rapid and standardized collection of saliva RNA and proteins.

Authors:  Samantha H Chiang; Gerald A Thomas; Wei Liao; Tristan Grogan; Robert L Buck; Laurel Fuentes; Maha Yakob; Mary J Laughlin; Chris Schafer; Abu Nazmul-Hossain; Fang Wei; David Elashoff; Paul D Slowey; David T W Wong
Journal:  Biotechniques       Date:  2015-02-01       Impact factor: 1.993

5.  Tumor-suppressor Gene Promoter Hypermethylation in Saliva of Head and Neck Cancer Patients.

Authors:  Dmitry A Ovchinnikov; Matthew A Cooper; Pratibala Pandit; William B Coman; Justin J Cooper-White; Patricia Keith; Ernst J Wolvetang; Paul D Slowey; Chamindie Punyadeera
Journal:  Transl Oncol       Date:  2012-10-01       Impact factor: 4.243

6.  Evaluation of HPV-16 and HPV-18 specific antibody measurements in saliva collected in oral rinses and merocel® sponges.

Authors:  Katherine H Parker; Troy J Kemp; Yuanji Pan; Zhen Yang; Anna R Giuliano; Ligia A Pinto
Journal:  Vaccine       Date:  2018-04-06       Impact factor: 3.641

Review 7.  Toilet-based continuous health monitoring using urine.

Authors:  Savas Tasoglu
Journal:  Nat Rev Urol       Date:  2022-01-21       Impact factor: 14.432

8.  Spatially resolved sampling for untargeted metabolomics: A new tool for salivomics.

Authors:  Alessio Ciurli; Maximiliam Liebl; Rico J E Derks; Jacques J C Neefjes; Martin Giera
Journal:  iScience       Date:  2021-06-24

9.  NT-ProBNP levels in saliva and its clinical relevance to heart failure.

Authors:  Jared Yong Yang Foo; Yunxia Wan; Karam Kostner; Alicia Arivalagan; John Atherton; Justin Cooper-White; Goce Dimeski; Chamindie Punyadeera
Journal:  PLoS One       Date:  2012-10-31       Impact factor: 3.240

10.  Measurement of salivary resistin level in patients with type 2 diabetes.

Authors:  Jinhua Yin; Hongfei Gao; Jing Yang; Lu Xu; Ming Li
Journal:  Int J Endocrinol       Date:  2012-08-30       Impact factor: 3.257