Literature DB >> 22401920

Impact of immobilization on intrafraction motion for spine stereotactic body radiotherapy using cone beam computed tomography.

Winnie Li1, Arjun Sahgal, Matthew Foote, Barbara-Ann Millar, David A Jaffray, Daniel Letourneau.   

Abstract

PURPOSE: Spine stereotactic body radiotherapy (SBRT) involves tight planning margins and steep dose gradients to the surrounding organs at risk (OAR). This study aimed to assess intrafraction motion using cone beam computed tomography (CBCT) for spine SBRT patients treated using three immobilization devices. METHODS AND MATERIALS: Setup accuracy using CBCT was retrospectively analyzed for 102 treated spinal metastases in 84 patients. Thoracic and lumbar spine patients were immobilized with either an evacuated cushion (EC, n = 24) or a semirigid vacuum body fixation (BF, n = 60). For cases treated at cervical/upper thoracic (thoracic [T]1-T3) vertebrae, a thermoplastic S-frame (SF) mask (n = 18) was used. Patient setup was corrected by using bony anatomy image registration and couch translations only (no rotation corrections) with shifts confirmed on verification CBCTs. Repeat imaging was performed mid- and post-treatment. Patient translational and rotational positioning data were recorded to calculate means, standard deviations (SD), and corresponding margins ± 2 SD for residual setup errors and intrafraction motion.
RESULTS: A total of 355 localizations, 333 verifications, and 248 mid- and 280 post-treatment CBCTs were analyzed. Residual translations and rotations after couch corrections (verification scans) were similar for all immobilization systems, with SDs of 0.6 to 0.9 mm in any direction and 0.9° to 1.6°, respectively. Margins to encompass residual setup errors after couch corrections were within 2 mm. Including intrafraction motion, as measured on post-treatment CBCTs, SDs for total setup error in the left-right, cranial-caudal, and anterior-posterior directions were 1.3, 1.2, and 1.0 mm for EC; 0.9, 0.7, and 0.9 mm for BF; and 1.3, 0.9, and 1.1 mm for SF, respectively. The calculated margins required to encompass total setup error increased to 3 mm for EC and SF and remained within 2 mm for BF.
CONCLUSION: Following image guidance, residual setup errors for spine SBRT were similar across three immobilization systems. The BF device resulted in the least amount of intrafraction motion, and based on this device, we justify a 2-mm margin for the planning OAR and target volume.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22401920     DOI: 10.1016/j.ijrobp.2011.12.039

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  26 in total

1.  Hybrid Therapy for Metastatic Epidural Spinal Cord Compression: Technique for Separation Surgery and Spine Radiosurgery.

Authors:  Ori Barzilai; Ilya Laufer; Adam Robin; Ran Xu; Yoshiya Yamada; Mark H Bilsky
Journal:  Oper Neurosurg (Hagerstown)       Date:  2019-03-01       Impact factor: 2.703

2.  Is helical tomotherapy accurate and safe enough for spine stereotactic body radiotherapy?

Authors:  Yoonsun Chung; Hong In Yoon; Joo Ho Kim; Ki Chang Nam; Woong Sub Koom
Journal:  J Cancer Res Clin Oncol       Date:  2012-10-02       Impact factor: 4.553

3.  The era of stereotactic body radiotherapy for spinal metastases and the multidisciplinary management of complex cases.

Authors:  Rachit Kumar; Anick Nater; Ahmed Hashmi; Sten Myrehaug; Young Lee; Lijun Ma; Kristin Redmond; Simon S Lo; Eric L Chang; Albert Yee; Charles G Fisher; Michael G Fehlings; Arjun Sahgal
Journal:  Neurooncol Pract       Date:  2015-07-27

Review 4.  Radiation myelopathy following stereotactic body radiation therapy for spine metastases.

Authors:  Wee Loon Ong; Shun Wong; Hany Soliman; Sten Myrehaug; Chia-Lin Tseng; Jay Detsky; Zain Husain; Pejman Maralani; Lijun Ma; Simon S Lo; Arjun Sahgal
Journal:  J Neurooncol       Date:  2022-06-23       Impact factor: 4.506

5.  Decompose kV projection using neural network for improved motion tracking in paraspinal SBRT.

Authors:  Xiuxiu He; Weixing Cai; Feifei Li; Qiyong Fan; Pengpeng Zhang; John J Cuaron; Laura I Cerviño; Xiang Li; Tianfang Li
Journal:  Med Phys       Date:  2021-10-28       Impact factor: 4.506

Review 6.  Stereotactic body radiotherapy: a new paradigm in the management of spinal metastases.

Authors:  Zain A Husain; Isabelle Thibault; Daniel Letourneau; Lijun Ma; Harald Keller; John Suh; Veronica Chiang; Eric L Chang; Raja K Rampersaud; James Perry; David A Larson; Arjun Sahgal
Journal:  CNS Oncol       Date:  2013-05

7.  Prospective evaluation of target and spinal cord motion and dosimetric changes with respiration in spinal stereotactic body radiation therapy utilizing 4-D CT.

Authors:  Xin Wang; Amol J Ghia; Zhongxiang Zhao; Jinzhong Yang; Dershan Luo; Tina M Briere; Ramiro Pino; Jing Li; Mary F McAleer; David C Weksberg; Eric L Chang; Paul D Brown; James N Yang
Journal:  J Radiosurg SBRT       Date:  2016

8.  Technical Note: Synthetic treatment beam imaging for motion monitoring during spine SBRT treatments - a phantom study.

Authors:  Tianfang Li; Feifei Li; Weixing Cai; Pengpeng Zhang; Xiang Li
Journal:  Med Phys       Date:  2020-12-07       Impact factor: 4.071

9.  Feasibility study of automated framework for estimating lung tumor locations for target-based patient positioning in stereotactic body radiotherapy.

Authors:  Satoshi Yoshidome; Hidetaka Arimura; Katsumasa Nakamura; Yoshiyuki Shioyama; Kazushige Atsumi; Yasuhiko Nakamura; Hideki Yoshikawa; Kei Nishikawa; Hideki Hirata
Journal:  Biomed Res Int       Date:  2015-01-05       Impact factor: 3.411

10.  Technical know-how in stereotactic ablative radiotherapy (SABR).

Authors:  Simon S Lo; Matthew Foote; Shankar Siva; Ben J Slotman; Bin S Teh; Matthias Guckenberger; Daniel Tan; Nina A Mayr; Arjun Sahgal
Journal:  J Med Radiat Sci       Date:  2016-03-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.