Quantitative evaluation of liver cirrhosis using T1 relaxation time with 3 tesla MRI before and after oxygen inhalation.

Kyung Ah Kim1, Mi-Suk Park, In-Seong Kim, Berthold Kiefer, Woo-Suk Chung, Myeong-Jin Kim, Ki Whang Kim.   

Abstract

PURPOSE: To quantify liver T1 relaxation times before and after oxygen inhalation in patients with and without liver cirrhosis using a 3 Tesla (T) MRI.
MATERIALS AND METHODS: Institutional Review Board approval and written informed consent were obtained. Ninety-two noncirrhotic patients and 87 patients with hepatitis B viral liver cirrhosis (72 Child-Pugh class A and 15 Child-Pugh class B or C) underwent MRI with a 3.0T system before and after the supply of 100% oxygen at a rate of 15 L/min by means of a nonrebreather ventilation mask for 3 min. T1 maps were acquired using three-dimensional spoiled gradient echo sequences with two different flip angles (2° and 14°) and a fixed TR/TE (2.54 ms/0.95 ms). Liver T1 values were obtained using a T1 processing tool (MapIT software). The mean baseline T1 values of three groups (control, Child-Pugh class A, and Child-Pugh class B/C) were compared using an analysis of variance test. Liver T1 value before and after oxygenation was compared using a paired t-test for each group.
RESULTS: The baseline liver T1 value was significantly higher in the control group (941 ± 136 ms) than in Child-Pugh A (858 ± 143 ms) and Child-Pugh B/C (783 ± 164 ms) group (P < 0.001 and P < 0.0001). The reduction in the liver T1 value after oxygen inhalation was significant in the control group (P = 0.012) but not significant in Child-Pugh class A (P = 0.079) and Child-Pugh class B/C (P = 0.752).
CONCLUSION: The baseline liver T1 relaxation time was significantly different between the patients with and without liver cirrhosis. The shortening effect of oxygen on the liver T1 value was significant in the control group but not in the cirrhotic patients.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22392835     DOI: 10.1002/jmri.23620

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  30 in total

1.  Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE-MRI: Results from a multicenter phantom study.

Authors:  Octavia Bane; Stefanie J Hectors; Mathilde Wagner; Lori L Arlinghaus; Madhava P Aryal; Yue Cao; Thomas L Chenevert; Fiona Fennessy; Wei Huang; Nola M Hylton; Jayashree Kalpathy-Cramer; Kathryn E Keenan; Dariya I Malyarenko; Robert V Mulkern; David C Newitt; Stephen E Russek; Karl F Stupic; Alina Tudorica; Lisa J Wilmes; Thomas E Yankeelov; Yi-Fei Yen; Michael A Boss; Bachir Taouli
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

2.  Efficacy of liver parenchymal enhancement and liver volume to standard liver volume ratio on Gd-EOB-DTPA-enhanced MRI for estimation of liver function.

Authors:  Tomohide Yoneyama; Yoshihiko Fukukura; Kiyohisa Kamimura; Koji Takumi; Aya Umanodan; Shinichi Ueno; Masayuki Nakajo
Journal:  Eur Radiol       Date:  2013-12-20       Impact factor: 5.315

3.  A multi-scale residual network for accelerated radial MR parameter mapping.

Authors:  Zhiyang Fu; Sagar Mandava; Mahesh B Keerthivasan; Zhitao Li; Kevin Johnson; Diego R Martin; Maria I Altbach; Ali Bilgin
Journal:  Magn Reson Imaging       Date:  2020-09-01       Impact factor: 2.546

4.  Influence of fat deposition on T1 mapping of the pancreas: evaluation by dual-flip-angle MR imaging with and without fat suppression.

Authors:  Mayumi Higashi; Masahiro Tanabe; Munemasa Okada; Matakazu Furukawa; Etsushi Iida; Katsuyoshi Ito
Journal:  Radiol Med       Date:  2019-09-27       Impact factor: 3.469

5.  Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging.

Authors:  Jeong Hee Yoon; Jeong Min Lee; Munyoung Paek; Joon Koo Han; Byung Ihn Choi
Journal:  Eur Radiol       Date:  2015-09-15       Impact factor: 5.315

6.  Evaluation of variable flip angle, MOLLI, SASHA, and IR-SNAPSHOT pulse sequences for T1 relaxometry and extracellular volume imaging of the pancreas and liver.

Authors:  Temel Tirkes; Xuandong Zhao; Chen Lin; Alex Jordan Stuckey; Liang Li; Shivriman Giri; Dominik Nickel
Journal:  MAGMA       Date:  2019-06-04       Impact factor: 2.310

7.  Quantitative assessment of disease severity of primary sclerosing cholangitis with T1 mapping and extracellular volume imaging.

Authors:  Sehnaz Evrimler; Jordan K Swensson; Vijay S Are; Temel Tirkes; Raj Vuppalanchi; Fatih Akisik
Journal:  Abdom Radiol (NY)       Date:  2020-11-01

8.  Magnetic resonance imaging as a non-invasive method for the assessment of pancreatic fibrosis (MINIMAP): a comprehensive study design from the consortium for the study of chronic pancreatitis, diabetes, and pancreatic cancer.

Authors:  Temel Tirkes; Dhiraj Yadav; Darwin L Conwell; Paul R Territo; Xuandong Zhao; Sudhakar K Venkatesh; Arunark Kolipaka; Liang Li; Joseph R Pisegna; Stephen J Pandol; Walter G Park; Mark Topazian; Jose Serrano; Evan L Fogel
Journal:  Abdom Radiol (NY)       Date:  2019-08

9.  Rapid volumetric T1 mapping of the abdomen using three-dimensional through-time spiral GRAPPA.

Authors:  Yong Chen; Gregory R Lee; Gunhild Aandal; Chaitra Badve; Katherine L Wright; Mark A Griswold; Nicole Seiberlich; Vikas Gulani
Journal:  Magn Reson Med       Date:  2015-05-18       Impact factor: 4.668

10.  MR Fingerprinting for Rapid Quantitative Abdominal Imaging.

Authors:  Yong Chen; Yun Jiang; Shivani Pahwa; Dan Ma; Lan Lu; Michael D Twieg; Katherine L Wright; Nicole Seiberlich; Mark A Griswold; Vikas Gulani
Journal:  Radiology       Date:  2016-01-21       Impact factor: 11.105

View more