Literature DB >> 22387039

Label-free colorimetric sensor for ultrasensitive detection of heparin based on color quenching of gold nanorods by graphene oxide.

Xiuli Fu1, Lingxin Chen, Jinhua Li, Meng Lin, Huiyan You, Wenhai Wang.   

Abstract

A novel label-free colorimetric strategy was developed for ultrasensitive detection of heparin by using the super color quenching capacity of graphene oxide (GO). Hexadecyltrimethylammonium bromide (CTAB)-stabilized gold nanorods (AuNRs) could easily self-assembly onto the surface of GO through electrostatic interaction, resulting in decrease of the surface plasmon resonance (SPR) absorption and consequent color quenching change of the AuNRs from deep to light. Polycationic protamine was used as a medium for disturbing the electrostatic interaction between AuNRs and GO. The AuNRs were prevented from being adsorbed onto the surface of GO because of the stronger interaction between protamine and GO, showing a native color of the AuNRs. On the contrary, in the presence of heparin, which was more easily to combine with protamine, the AuNRs could self-assembly onto the surface of GO, resulting in the native color disappearing of AuNRs. As the concentration of heparin increased, the color of AuNRs would gradually fade until almost colorless. The amounts of self-assembly AuNRs were proportional to the concentration of heparin, and thereby the changes in the SPR absorption and color had been used to monitor heparin levels. Under optimized conditions, good linearity was obtained in a range of 0.02-0.28 μg/mL (R=0.9957), and a limit of detection was 5 ng/mL. The simultaneous possession of high sensitivity and selectivity, simplicity, rapidity, and visualization enabled this sensor to be potentially applicable for ultrasensitive and rapid on-site detection toward trace heparin. Copyright Â
© 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22387039     DOI: 10.1016/j.bios.2012.02.008

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  7 in total

1.  Long-wavelength fluorescent reporters for monitoring protein kinase activity.

Authors:  Nathan P Oien; Luong T Nguyen; Finith E Jernigan; Melanie A Priestman; David S Lawrence
Journal:  Angew Chem Int Ed Engl       Date:  2014-03-06       Impact factor: 15.336

2.  A Nanoscale Tool for Photoacoustic-Based Measurements of Clotting Time and Therapeutic Drug Monitoring of Heparin.

Authors:  Junxin Wang; Fang Chen; Santiago J Arconada-Alvarez; James Hartanto; Li-Peng Yap; Ryan Park; Fang Wang; Ivetta Vorobyova; Grant Dagliyan; Peter S Conti; Jesse V Jokerst
Journal:  Nano Lett       Date:  2016-09-28       Impact factor: 11.189

3.  Enhanced DNA sensing via catalytic aggregation of gold nanoparticles.

Authors:  Herbert M Huttanus; Elton Graugnard; Bernard Yurke; William B Knowlton; Wan Kuang; William L Hughes; Jeunghoon Lee
Journal:  Biosens Bioelectron       Date:  2013-07-11       Impact factor: 10.618

4.  A ratiometric fluorometric heparin assay based on the use of CdTe and polyethyleneimine-coated carbon quantum dots.

Authors:  Si-Si Liang; Xu Deng; Yao-Yao Fan; Jun Li; Man Wang; Zhi-Qi Zhang
Journal:  Mikrochim Acta       Date:  2018-10-25       Impact factor: 5.833

5.  Chitosan-capped gold nanoparticles for selective and colorimetric sensing of heparin.

Authors:  Zhanguang Chen; Zhen Wang; Xi Chen; Haixiong Xu; Jinbin Liu
Journal:  J Nanopart Res       Date:  2013-08-25       Impact factor: 2.253

6.  Colorimetric sensing strategy for heparin assay based on PDDA-induced aggregation of gold nanoparticles.

Authors:  Xiaoyi Ma; Xinyue Kou; Yuanyuan Xu; Dawei Yang; Peng Miao
Journal:  Nanoscale Adv       Date:  2018-10-01

7.  Controlled fluorescence quenching by antibody-conjugated graphene oxide to measure tau protein.

Authors:  Ao Huang; Luning Zhang; Weiwei Li; Zeyu Ma; Shi Shuo; Tianming Yao
Journal:  R Soc Open Sci       Date:  2018-04-11       Impact factor: 2.963

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.