Literature DB >> 22383064

In vitro cyclic shear fatigue of the bracket-adhesive complex: a pilot study.

N Daratsianos1, A Jäger, T Eliades, C Bourauel.   

Abstract

OBJECTIVE: The aim of this study was to describe the effect of fatigue on the shear strength of the bracket-adhesive complex.
MATERIALS AND METHODS: Brackets with laser-structured (Discovery®, Dentaurum) and foil mesh bases (Ultra-Minitrim®, Dentaurum) were bonded onto silanized stainless steel flat plates with two chemically curing adhesives (No-Mix Bonding System, Dentaurum; Concise™, 3M Unitek) and aged in distilled water at 37°C for 3 days. One group of specimens was used to determine shear-bond strength. The second group underwent shear-fatigue testing with a testing machine (Zwick 1445) according to the staircase method for 1,000 cycles, and the surviving specimens were subjected to shear-strength testing. The shear strength of the fatigued and non-fatigued specimens were then compared.
RESULTS: Fatigued specimens demonstrated an 8% gain in shear strength in material group A (Discovery®/No-Mix) and a 10% loss of shear strength in material group D (Ultra-Minitrim®/Concise™) compared to the non-fatigued group. We observed no statistically significant differences in material groups B (Ultra-Minitrim®/No-Mix) and C (Discovery®/Concise™). The fatigue ratio varied between 60% and 67%. Among the non-fatigued specimens, the bracket Discovery® with laser-structured base showed circa 59% greater shear strength than the foil-mesh bracket Ultra-Minitrim®, and the adhesive Concise™ about 66% more shear strength than the No-Mix.
CONCLUSION: Shear fatigue of the bracket-adhesive complex for 1,000 cycles revealed a variable, material-dependent influence on the shear strength of the bracket-adhesive complex. However, the effect of fatigue on shear strength was less significant than the effect of other factors such as bracket and adhesive type.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22383064     DOI: 10.1007/s00056-011-0069-5

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  24 in total

1.  The inappropriateness of conventional orthodontic bond strength assessment protocols.

Authors:  T Eliades; W A Brantley
Journal:  Eur J Orthod       Date:  2000-02       Impact factor: 3.075

2.  Monotonic flexure and fatigue strength of composites for provisional and definitive restorations.

Authors:  Susanne S Scherrer; Anselm H W Wiskott; Viviana Coto-Hunziker; Urs C Belser
Journal:  J Prosthet Dent       Date:  2003-06       Impact factor: 3.426

3.  Comparison of bond strength between simple foil mesh and laser-structured base retention brackets.

Authors:  Olivier Sorel; Rafeh El Alam; Francis Chagneau; Guy Cathelineau
Journal:  Am J Orthod Dentofacial Orthop       Date:  2002-09       Impact factor: 2.650

4.  Effect of fatigue upon the interfacial bond strength of repaired composite resins.

Authors:  W P Saunders
Journal:  J Dent       Date:  1990-06       Impact factor: 4.379

5.  Initial and fatigue bond strengths of chromatic and light-cured adhesives.

Authors:  June M L Lee; George Georgiou; Steven P Jones
Journal:  Aust Orthod J       Date:  2010-11

6.  The effect of different light-curing units on fatigue behavior and degree of conversion of a resin composite.

Authors:  Ulrich Lohbauer; Christos Rahiotis; Norbert Krämer; Anselm Petschelt; George Eliades
Journal:  Dent Mater       Date:  2005-07       Impact factor: 5.304

7.  Compressive strength and compressive fatigue limit of conventional and high viscosity posterior resin composites.

Authors:  Letícia Brandão; Gelson Luis Adabo; Luís Geraldo Vaz; José Roberto Cury Saad
Journal:  Braz Oral Res       Date:  2006-02-14

8.  Bond strength evaluation of ceramic and stainless steel bracket bases subjected to cyclic tensile loading.

Authors:  Scott A Soderquist; James L Drummond; Carla A Evans
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-02       Impact factor: 2.650

9.  Compressive fatigue limits of composite restorative materials.

Authors:  R A Draughn
Journal:  J Dent Res       Date:  1979-03       Impact factor: 6.116

10.  In vitro fatigue testing of a dental bonding system on enamel.

Authors:  N D Ruse; R Shew; D Feduik
Journal:  J Biomed Mater Res       Date:  1995-03
View more
  1 in total

1.  Effect of Cyclic Loading on Shear Bond Strength of Orthodontic Brackets: An In Vitro Study.

Authors:  Mohammad Moslem Imani; Farzaneh Aghajani; Nafiseh Momeni; Mohammad Sadegh Ahmad Akhoundi
Journal:  J Dent (Tehran)       Date:  2018-11
  1 in total