Literature DB >> 22380648

Prosthetic requirements for immediate implant loading: a review.

Wiam El Ghoul1, José Johann Chidiac.   

Abstract

PURPOSE: The aim of this article is to review the current literature with regard to prosthetic considerations and their influence on the outcome of immediately loaded implants.
MATERIALS AND METHODS: A broad search of the published literature was performed using MEDLINE and PubMed to identify pertinent articles.
RESULTS: One hundred fifty six references were selected. They were mainly descriptive, prospective, follow-up studies. They were reviewed and were categorized with respect to 6 factors that influence immediate loading: cross-arch stability and micromovements, interim prostheses, definitive restorations inserted immediately, screw- or cement-retained prostheses, occlusion, and number and distribution of implants in overdentures and fixed prostheses.
CONCLUSION: Immediate loading seems to be a relatively safe procedure. From the prosthodontic point of view, there are specific guidelines to follow. They are: implants should be splinted with a metallic bar and acrylic interim prostheses until full osseointegration occurs. To have a successful outcome, screw-retained interim prostheses are recommended. CAD/CAM systems can improve the placement of implants with minimum risk. Regarding occlusion, there is a disagreement on when and how to provide occlusal contacts, but all authors agree on keeping centric contacts only. Finally, concerning the number of implants required for an immediate overdenture, no conclusive evidence could be found.
© 2012 by the American College of Prosthodontists.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22380648     DOI: 10.1111/j.1532-849X.2011.00819.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  8 in total

1.  Comparative investigation of primary stability of four different dental implants in low-density bone model.

Authors:  Saied Nokar; Amirali Reza Rasouli-Ghahroudi; Elham Shidvash; Faezeh Atri
Journal:  Dent Res J (Isfahan)       Date:  2019 Jan-Feb

2.  Scanning Electron Microscope (SEM) Evaluation of the Interface between a Nanostructured Calcium-Incorporated Dental Implant Surface and the Human Bone.

Authors:  Francesco Mangano; Mario Raspanti; Hassan Maghaireh; Carlo Mangano
Journal:  Materials (Basel)       Date:  2017-12-17       Impact factor: 3.623

3.  Fixed Full Arches Supported by Tapered Implants with Knife-Edge Thread Design and Nanostructured, Calcium-Incorporated Surface: A Short-Term Prospective Clinical Study.

Authors:  Soheil Bechara; Algirdas Lukosiunas; Giorgio Andrea Dolcini; Ricardas Kubilius
Journal:  Biomed Res Int       Date:  2017-01-29       Impact factor: 3.411

4.  Immediate occlusal vs nonocclusal loading of implants: A randomized prospective clinical pilot study and patient centered outcome after 36 months.

Authors:  Susanne Vogl; Marlene Stopper; Markus Hof; Kerstin Theisen; Walther A Wegscheider; Martin Lorenzoni
Journal:  Clin Implant Dent Relat Res       Date:  2019-05-07       Impact factor: 3.932

5.  The limit of tolerable micromotion for implant osseointegration: a systematic review.

Authors:  Nupur Kohli; Jennifer C Stoddart; Richard J van Arkel
Journal:  Sci Rep       Date:  2021-05-24       Impact factor: 4.379

6.  The effect of loading time on marginal bone change of implants immediately placed after extraction: a retrospective study.

Authors:  Sung-Jae Lee; Euy-Hyun Kim; Dong-Keon Lee; In-Seok Song; Sang-Ho Jun
Journal:  Int J Implant Dent       Date:  2022-10-04

Review 7.  Bimaxillary simultaneous immediate loading of full-arch restorations: A case series.

Authors:  Iñaki Cercadillo-Ibarguren; Alba Sánchez-Torres; Rui Figueiredo; Eduard Valmaseda-Castellón
Journal:  J Clin Exp Dent       Date:  2017-09-01

8.  The Effect of Different Cleaning Protocols of Polymer-Based Prosthetic Materials on the Behavior of Human Gingival Fibroblasts.

Authors:  Vygandas Rutkunas; Rokas Borusevicius; Dominyka Liaudanskaite; Urte Jasinskyte; Saulius Drukteinis; Virginija Bukelskiene; Eitan Mijiritsky
Journal:  Int J Environ Res Public Health       Date:  2020-10-23       Impact factor: 3.390

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.