Literature DB >> 22375617

Analysis of factors influencing accuracy and complications in CT-guided lung biopsy.

Miyuki Nakatani1, Noboru Tanigawa, Shuji Kariya, Atsushi Komemushi, Rie Yagi, Satoshi Sawada.   

Abstract

INTRODUCTION: This study aimed to analyze factors influencing accuracy and complications in patients who underwent computed tomography (CT)-guided lung biopsy at our medical center.
MATERIAL AND METHODS: This study included all 107 patients (72 men, 35 women; mean age, 69 years; range, 41-83 years) who underwent CT-guided lung biopsy between January 2006 and October 2009. CT fluoroscopy was used in 45.7% of cases. Final diagnosis, when surgical resection was performed, was histopathological diagnosis from the lung lesion specimen, and when resection was not performed, clinical diagnosis after ≥6 months of follow-up. The accuracy of lung biopsy was assessed by comparison of biopsy results and final diagnosis. The influence of factors on accuracy was statistically analyzed.
RESULTS: Accuracy of CT-guided lung biopsy was 89.4%. None of the factors, including lesion size, lesion depth from pleura, lesion location, patient position, final diagnosis, and use or non-use of CT fluoroscopy, had any significant influence on accuracy. The only complications were Grade 1 and 2 pneumothorax and Grade 1 pulmonary bleeding. The incidence of pneumothorax and bleeding was significantly increased with smaller lesion size and significantly increased with greater lesion depth. In patients with pulmonary emphysema, bleeding was significantly less (p = 0.022). When CT fluoroscopy was used, bleeding was significantly increased (p < 0.001).
CONCLUSIONS: None of the factors had any significant influence on accuracy. The incidence of pneumothorax and bleeding was affected by lesion size and lesion depth. When CT fluoroscopy was used, bleeding was significantly increased.

Entities:  

Mesh:

Year:  2012        PMID: 22375617     DOI: 10.3109/13645706.2012.662155

Source DB:  PubMed          Journal:  Minim Invasive Ther Allied Technol        ISSN: 1364-5706            Impact factor:   2.442


  10 in total

1.  Efficacy of an opposite position aspiration on resolution of pneumothorax following CT-guided lung biopsy.

Authors:  L-C Zeng; Y Du; H-F Yang; M-G Xie; H-Q Liao; Y-D Zhang; L Li; Q Wang; L Hu; X-X Xu
Journal:  Br J Radiol       Date:  2015-05-12       Impact factor: 3.039

2.  Logistic regression analysis and a risk prediction model of pneumothorax after CT-guided needle biopsy.

Authors:  Yanfeng Zhao; Xiaoyi Wang; Yong Wang; Zheng Zhu
Journal:  J Thorac Dis       Date:  2017-11       Impact factor: 2.895

3.  Patient reported experiences of CT guided lung biopsy: a prospective cohort study.

Authors:  Naomi Winn; Jonathan Spratt; Enid Wright; Julie Cox
Journal:  Multidiscip Respir Med       Date:  2014-10-31

4.  Complications of CT-guided lung biopsy with a non-coaxial semi-automated 18 gauge biopsy system: Frequency, severity and risk factors.

Authors:  Amany Saad Elshafee; Annika Karch; Kristina I Ringe; Hoen-Oh Shin; Hans-Jürgen Raatschen; Nermin Yehia Soliman; Frank Wacker; Jens Vogel-Claussen
Journal:  PLoS One       Date:  2019-03-18       Impact factor: 3.240

5.  Non-diagnostic Results of Percutaneous Transthoracic Needle Biopsy: A Meta-analysis.

Authors:  Kum Ju Chae; Hyunsook Hong; Soon Ho Yoon; Seokyung Hahn; Gong Yong Jin; Chang Min Park; Jin Mo Goo
Journal:  Sci Rep       Date:  2019-08-27       Impact factor: 4.379

6.  Contrast-enhanced computed tomography prior to percutaneous transthoracic needle biopsy reduces the incidence of hemorrhage.

Authors:  Huan Hu; Chuling Li; Tangfeng Lv; Huijuan Li; Yangbo Hu; Qin Shen; Mari Mino-Kenudson; Luca Bertolaccini; Gaetano Rocco; Pavlos Zarogoulidis; Fang Zhang; Dang Lin; Hongbing Liu; Yong Song
Journal:  Ann Transl Med       Date:  2021-02

7.  Clinical value of an electromagnetic navigation system for CT-guided percutaneous lung biopsy of peripheral lung lesions.

Authors:  Yao Zhang; Haozhe Huang; Shuhui Cao; Jiajun Teng; Yue Wang; Xuxinyi Ling; Yan Zhou; Jianlin Xu; Wentao Li; Hua Zhong
Journal:  J Thorac Dis       Date:  2021-08       Impact factor: 2.895

Review 8.  Computed Tomography-guided Lung Biopsy: A Review of Techniques for Reducing the Incidence of Complications.

Authors:  Kazuhiko Nakamura; Kensuke Matsumoto; Chie Inoue; Eiji Matsusue; Shinya Fujii
Journal:  Interv Radiol (Higashimatsuyama)       Date:  2021-11-01

9.  Manual aspiration in the biopsy-side down position to deal with delayed pneumothorax after lung biopsy.

Authors:  Li-Chuan Zeng; Han-Feng Yang; Xiao-Xue Xu; Ming-Guo Xie; Hua-Qiang Liao; Yu-Dong Zhang; Qu Wang; Yong Du
Journal:  J Thorac Dis       Date:  2018-01       Impact factor: 2.895

10.  CT-guided biopsy of lung lesions: defining the best needle option for a specific diagnosis.

Authors:  Marcos Duarte Guimarães; Edson Marchiori; Bruno Hochhegger; Rubens Chojniak; Jefferson Luiz Gross
Journal:  Clinics (Sao Paulo)       Date:  2014       Impact factor: 2.365

  10 in total