Literature DB >> 22374188

BOD biosensors for pulp and paper industry wastewater analysis.

Merlin Raud1, Marti Tutt, Eerik Jõgi, Timo Kikas.   

Abstract

INTRODUCTION: Two semi-specific microbial biosensors were constructed for the analysis of biochemical oxygen demand (BOD) in high-cellulose-content pulp and paper industry wastewaters. The biosensors were based on living cells of Bacillus subtilis and Paenibacillus sp. immobilized in an agarose gel matrix. Semi-specific microorganisms were isolated from various samples (decaying sawdust and rabbit manure) and were chosen based on their ability to assimilate cellulose. MATERIALS &
METHODS: The biosensors were calibrated with the Organization for Economic Cooperation and Development synthetic wastewater, and measurements with different wastewaters were conducted.
RESULTS: The response time of biosensors using the steady-state method was 20-25 min, and the service life of immobilized microorganisms was 96 days. Detection limit was 5 mg/l of BOD(7) while linear ranges extended up to 55 and 50 mg/l of the BOD(7) for B. subtilis- and Paenibacillus sp.-based biosensors, respectively. Repeatability and reproducibility of both biosensors were within the limits set by APHA-less than 15.4%. In comparison, both biosensors overestimated the BOD(7) values in paper mill wastewaters and underestimated the BOD(7) in aspen pulp mill wastewater.
CONCLUSIONS: The semi-specific biosensors are suitable for the estimation of organic pollution derived from cellulose, while the detection of pollution derived from tannins and lignins was minor. Better results in terms of accuracy and repeatability were gained with Paenibacillus sp. biosensor.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22374188     DOI: 10.1007/s11356-012-0817-0

Source DB:  PubMed          Journal:  Environ Sci Pollut Res Int        ISSN: 0944-1344            Impact factor:   4.223


  14 in total

Review 1.  The treatment of pulp and paper mill effluent: a review.

Authors:  G Thompson; J Swain; M Kay; C F Forster
Journal:  Bioresour Technol       Date:  2001-05       Impact factor: 9.642

2.  Electrochemical biosensors: recommended definitions and classification.

Authors:  D R Thévenot; K Toth; R A Durst; G S Wilson
Journal:  Biosens Bioelectron       Date:  2001-01       Impact factor: 10.618

3.  Screening and isolation of a cellulolytic and amylolytic Bacillus from sago pith waste.

Authors:  Kasing Apun; Bor Chyan Jong; Mohd. Azib Salleh
Journal:  J Gen Appl Microbiol       Date:  2000-10       Impact factor: 1.452

4.  Development and characterization of a novel immobilized microbial membrane for rapid determination of biochemical oxygen demand load in industrial waste-waters.

Authors:  Shikha Rastogi; Anil Kumar; N K Mehra; S D Makhijani; A Manoharan; V Gangal; Rita Kumar
Journal:  Biosens Bioelectron       Date:  2003-01       Impact factor: 10.618

5.  Microbial BOD sensors for wastewater analysis.

Authors:  Jing Liu; Bo Mattiasson
Journal:  Water Res       Date:  2002-09       Impact factor: 11.236

6.  Development of mediated BOD biosensor system of flow injection mode for shochu distillery wastewater.

Authors:  Shinichi Oota; Yuta Hatae; Kei Amada; Hidekazu Koya; Mitsuyasu Kawakami
Journal:  Biosens Bioelectron       Date:  2010-07-01       Impact factor: 10.618

7.  Short-term BOD (BODst) as a parameter for on-line monitoring of biological treatment process. Part I. A novel design of BOD biosensor for easy renewal of bio-receptor.

Authors:  Jing Liu; Gustaf Olsson; Bo Mattiasson
Journal:  Biosens Bioelectron       Date:  2004-10-15       Impact factor: 10.618

8.  An innovative reactor-type biosensor for BOD rapid measurement.

Authors:  Jianlong Wang; Yixin Zhang; Yeyao Wang; Runhua Xu; Zhonghua Sun; Zhou Jie
Journal:  Biosens Bioelectron       Date:  2009-12-23       Impact factor: 10.618

9.  Microbial electrode BOD sensors.

Authors:  I Karube; T Matsunaga; S Mitsuda; S Suzuki
Journal:  Biotechnol Bioeng       Date:  1977-10       Impact factor: 4.530

10.  A spectrophotometric biochemical oxygen demand determination method using 2,6-dichlorophenolindophenol as the redox color indicator and the eukaryote Saccharomyces cerevisiae.

Authors:  Hideaki Nakamura; Shun Kobayashi; Yu Hirata; Kyota Suzuki; Yotaro Mogi; Isao Karube
Journal:  Anal Biochem       Date:  2007-06-27       Impact factor: 3.365

View more
  3 in total

1.  Semi-specific Microbacterium phyllosphaerae-based microbial sensor for biochemical oxygen demand measurements in dairy wastewater.

Authors:  Elo Kibena; Merlin Raud; Eerik Jõgi; Timo Kikas
Journal:  Environ Sci Pollut Res Int       Date:  2012-09-08       Impact factor: 4.223

2.  Development of biological oxygen demand biosensor for monitoring the fermentation industry effluent.

Authors:  Neelam Verma; Ashish Kumar Singh
Journal:  ISRN Biotechnol       Date:  2012-11-27

3.  A Current Sensing Biosensor for BOD Rapid Measurement.

Authors:  Yiman Liu; Jie Li; Nianxin Wan; Tianyu Fu; Lili Wang; Cong Li; Zhonghui Qie; Ao Zhu
Journal:  Archaea       Date:  2020-10-26       Impact factor: 3.273

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.