Abstract

In this prospective study we studied the effect of the inclination angle of the acetabular component on polyethylene wear and component migration in cemented acetabular sockets using radiostereometric analysis. A total of 120 patients received either a cemented Reflection All-Poly ultra-high-molecular-weight polyethylene or a cemented Reflection All-Poly highly cross-linked polyethylene acetabular component, combined with either cobalt-chrome or Oxinium femoral heads. Femoral head penetration and migration of the acetabular component were assessed with repeated radiostereometric analysis for two years. The inclination angle was measured on a standard post-operative anteroposterior pelvic radiograph. Linear regression analysis was used to determine the relationship between the inclination angle and femoral head penetration and migration of the acetabular component. We found no relationship between the inclination angle and penetration of the femoral head at two years' follow-up (p = 0.9). Similarly, our data failed to reveal any statistically significant correlation between inclination angle and migration of these cemented acetabular components (p = 0.07 to p = 0.9).

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22371534     DOI: 10.1302/0301-620X.94B3.27460

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  4 in total

1.  Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

Authors:  George K Karidakis; Theofilos Karachalios
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

2.  Inferior stabilization of cementless compared with cemented dual-mobility cups in elderly osteoarthrosis patients: a randomized controlled radiostereometry study on 60 patients with 2 years' follow-up.

Authors:  Steffan Tabori-Jensen; Sebastian Breddam Mosegaard; Torben B Hansen; Maiken Stilling
Journal:  Acta Orthop       Date:  2020-02-06       Impact factor: 3.717

3.  Ceramic-on-ceramic versus ceramic-on-polyethylene in total hip arthroplasty: a comparative study at a minimum of 13 years follow-up.

Authors:  Malerba Giuseppe; Basilico Mattia; Bonfiglio Nadia; Vitiello Raffaele; Ruberto Pasquale; D' Adamio Stefano; Sirgiovanni Mattia; De Santis Vincenzo; Maccauro Giulio
Journal:  BMC Musculoskelet Disord       Date:  2022-01-17       Impact factor: 2.362

4.  Radiographic results on acetabular cup placement with the SuperPath technique: a retrospective study of 756 cases.

Authors:  Agostino Di Maro; Santo Creaco; Mattia Albini; Mahfuz Latiff; Marco Merlo
Journal:  BMC Musculoskelet Disord       Date:  2022-01-31       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.