Literature DB >> 22368126

Parametric subharmonic imaging using a commercial intravascular ultrasound scanner: an in vivo feasibility study.

John R Eisenbrey1, Anush Sridharan, Ebo D deMuinck, Marvin M Doyley, Flemming Forsberg.   

Abstract

OBJECTIVES: The feasibility of visualizing atherosclerotic plaque using parametric subharmonic intravascular ultrasound (IVUS) was investigated in vivo.
METHODS: Atherosclerosis was induced in the aorta of 2 rabbits. Following injection of Definity (Lantheus Medical Imaging, North Billerica, MA), radiofrequency IVUS signals were acquired at 40 MHz with a Galaxy IVUS scanner (Boston Scientific/Scimed, Natick, MA). Subharmonic imaging (SHI; receiving at 20 MHz) was performed offline by applying an 8-order equalization filter. Contrast-to-tissue ratios (CTRs) were computed for the vessel relative to the plaque area over 4 time points. Contrast-to-tissue ratios were also calculated for the plaque-tissue and vessel-tissue from 4 tissue regions of interest at 4 time points. Finally, parametric images showing the cumulative maximum intensity (CMI), time to peak, perfusion (PER), and time-integrated intensity (TII) were generated for the fundamental and subharmonic data sets, and CTR measurements were repeated.
RESULTS: Injection of the contrast agent resulted in improved delineation between plaque and the vessel lumen. Subharmonic imaging resulted in noticeable tissue suppression, although the intensity from the contrast agent was reduced. No significant improvement in the plaque to vessel lumen CTR was observed between the subharmonic and fundamental IVUS (2.1 ± 3.64 versus 2.2 ± 4.20; P = .5). However, the CTR for plaque-tissue was improved (11.8 ± 7.32 versus 9.9 ± 7.06; P < .0001) for SHI relative to fundamental imaging. Cumulative-maximum-intensity and TII maps of both fundamental and subharmonic data provided increased CTRs relative to nonparametric data sets (P < .002). Additionally, the CMI, PER, and TII of SHI IVUS showed significantly improved vessel-plaque CTRs for SHI relative to the fundamental (P < .04).
CONCLUSIONS: Parametric SHI IVUS of atherosclerotic plaque is feasible and improves the visualization of the plaque.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22368126      PMCID: PMC3576695          DOI: 10.7863/jum.2012.31.3.361

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  34 in total

1.  Subharmonic imaging of contrast agents.

Authors:  F Forsberg; W T Shi; B B Goldberg
Journal:  Ultrasonics       Date:  2000-03       Impact factor: 2.890

2.  Ultrasonic characterization of the nonlinear properties of contrast microbubbles.

Authors:  W T Shi; F Forsberg
Journal:  Ultrasound Med Biol       Date:  2000-01       Impact factor: 2.998

Review 3.  New developments in the detection of vulnerable plaque.

Authors:  M Naghavi; M Madjid; M R Khan; R M Mohammadi; J T Willerson; S W Casscells
Journal:  Curr Atheroscler Rep       Date:  2001-03       Impact factor: 5.113

4.  Nondestructive subharmonic imaging.

Authors:  James Chomas; Paul Dayton; Donovan May; Katherine Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-07       Impact factor: 2.725

5.  Association between plaque instability, angiogenesis and symptomatic carotid occlusive disease.

Authors:  R Mofidi; T B Crotty; P McCarthy; S J Sheehan; D Mehigan; T V Keaveny
Journal:  Br J Surg       Date:  2001-07       Impact factor: 6.939

Review 6.  Vulnerable plaque: the pathology of unstable coronary lesions.

Authors:  Renu Virmani; Allen P Burke; Frank D Kolodgie; Andrew Farb
Journal:  J Interv Cardiol       Date:  2002-12       Impact factor: 2.279

7.  Contrast-enhanced high resolution MRI for atherosclerotic carotid artery tissue characterization.

Authors:  Chun Yuan; William S Kerwin; Marina S Ferguson; Nayak Polissar; Shaoxiong Zhang; Jianming Cai; Thomas S Hatsukami
Journal:  J Magn Reson Imaging       Date:  2002-01       Impact factor: 4.813

8.  Parametric imaging using subharmonic signals from ultrasound contrast agents in patients with breast lesions.

Authors:  John R Eisenbrey; Jaydev K Dave; Daniel A Merton; Juan P Palazzo; Anne L Hall; Flemming Forsberg
Journal:  J Ultrasound Med       Date:  2011-01       Impact factor: 2.153

Review 9.  [Harmonic imaging. A new method of ultrasound imaging of brain perfusion].

Authors:  G Seidel; K Meyer
Journal:  Nervenarzt       Date:  2001-08       Impact factor: 1.214

10.  Quantitative magnetic resonance imaging analysis of neovasculature volume in carotid atherosclerotic plaque.

Authors:  William Kerwin; Andrew Hooker; Mary Spilker; Paolo Vicini; Marina Ferguson; Thomas Hatsukami; Chun Yuan
Journal:  Circulation       Date:  2003-02-18       Impact factor: 29.690

View more
  4 in total

1.  Contrast-Enhanced Quantitative Intravascular Elastography: The Impact of Microvasculature on Model-Based Elastography.

Authors:  Steven Huntzicker; Himanshu Shekhar; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2016-02-26       Impact factor: 2.998

2.  Combining Subharmonic and Ultraharmonic Modes for Intravascular Ultrasound Imaging: A Preliminary Evaluation.

Authors:  Himanshu Shekhar; Jeffrey S Rowan; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2017-08-26       Impact factor: 2.998

3.  Delineation of atherosclerotic plaque using subharmonic imaging filtering techniques and a commercial intravascular ultrasound system.

Authors:  Anush Sridharan; John R Eisenbrey; Priscilla Machado; Ebo D deMuinck; Marvin M Doyley; Flemming Forsberg
Journal:  Ultrason Imaging       Date:  2013-01       Impact factor: 1.578

Review 4.  Recent Experiences and Advances in Contrast-Enhanced Subharmonic Ultrasound.

Authors:  John R Eisenbrey; Anush Sridharan; Ji-Bin Liu; Flemming Forsberg
Journal:  Biomed Res Int       Date:  2015-05-18       Impact factor: 3.411

  4 in total