Literature DB >> 22358184

Microfluidic system for simultaneous optical measurement of platelet aggregation at multiple shear rates in whole blood.

Melissa Li1, David N Ku, Craig R Forest.   

Abstract

Thrombosis is the pathological formation of platelet aggregates which occlude blood flow causing stroke and heart attack-the leading causes of death in developed nations. Instrumentation for diagnosing and exploring treatments for pathological platelet aggregation thus has the potential for major clinical impact. Most current thrombosis methods focus on single flow conditions, non-occlusive platelet adhesion, or low shear rates and so are limited in their application to comparative studies involving multiple, pathological test conditions (e.g., shear rate, stenotic geometries that mimic arteries, and rapid platelet accumulation to occlusion). The field could benefit from a low volume, high throughput, short analysis time, and low cost system while minimizing sample handling. We report on the design, fabrication, testing, and application of a microfluidic device and associated optical system for simultaneous measurement of platelet aggregation at multiple initial shear rates within four stenotic channels in label-free whole blood. Following computational design, requisite shear rates were achieved in the device by micro- surface milling a mold and subsequent PDMS casting. We applied the microfluidic system to measure platelet aggregation in whole porcine blood for shear rates spanning physiological to pathological flow conditions (500-13000 s(-1)). Real-time, non-contact, label-free, microscope-free measurements of platelet aggregation were acquired using an optical system comprising a 650 nm diode laser and a linear CCD. We observed fully occlusive platelet aggregation in less than 20 min above a threshold initial shear rate of 4000 s(-1), and no occlusive platelet aggregation below 1500 s(-1) (N = 86 trials). Accumulation of thrombus was consistent between laser intensity, light microscopy, histology, and mass flow rate measurements. The amount of blood volumes producing occlusion were dependent on shear rate. Times to occlusion were not found to be dependent on shear rate above the threshold level of 4000 s(-1). This microfluidic system enables measurement of the entire process of occlusive platelet thrombosis in whole, unlabeled blood, in vitro, at multiple shear rates. Such a system may be useful as a point-of-care diagnostic tool for studying anti-platelet therapies in individual blood samples from high-risk patients. This journal is © The Royal Society of Chemistry 2012

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22358184     DOI: 10.1039/c2lc21145a

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  37 in total

1.  Migration distance-based platelet function analysis in a microfluidic system.

Authors:  Suk-Heung Song; Chae-Seung Lim; Sehyun Shin
Journal:  Biomicrofluidics       Date:  2013-11-04       Impact factor: 2.800

2.  Effects of upstream shear forces on priming of platelets for downstream adhesion and activation.

Authors:  Shekh M Rahman; Colin D Eichinger; Vladimir Hlady
Journal:  Acta Biomater       Date:  2018-04-11       Impact factor: 8.947

3.  Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

Authors:  Sivakkumar Arjunon; Pablo Hidalgo Ardana; Neelakantan Saikrishnan; Shalv Madhani; Brent Foster; Ari Glezer; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2015-02-11       Impact factor: 2.097

4.  Microfluidic measurement for blood flow and platelet adhesion around a stenotic channel: Effects of tile size on the detection of platelet adhesion in a correlation map.

Authors:  Sung Yong Jung; Eunseop Yeom
Journal:  Biomicrofluidics       Date:  2017-04-25       Impact factor: 2.800

5.  A microfluidic model of hemostasis sensitive to platelet function and coagulation.

Authors:  R M Schoeman; K Rana; N Danes; M Lehmann; J A Di Paola; A L Fogelson; K Leiderman; K B Neeves
Journal:  Cell Mol Bioeng       Date:  2016-10-24       Impact factor: 2.321

Review 6.  Micro total analysis systems: fundamental advances and applications in the laboratory, clinic, and field.

Authors:  Michelle L Kovarik; Douglas M Ornoff; Adam T Melvin; Nicholas C Dobes; Yuli Wang; Alexandra J Dickinson; Philip C Gach; Pavak K Shah; Nancy L Allbritton
Journal:  Anal Chem       Date:  2012-12-04       Impact factor: 6.986

Review 7.  Structure-function and regulation of ADAMTS-13 protease.

Authors:  X L Zheng
Journal:  J Thromb Haemost       Date:  2013-06       Impact factor: 5.824

8.  Bubble-free and pulse-free fluid delivery into microfluidic devices.

Authors:  Yang Jun Kang; Eunseop Yeom; Eunseok Seo; Sang-Joon Lee
Journal:  Biomicrofluidics       Date:  2014-01-29       Impact factor: 2.800

9.  The Margination of Particles in Areas of Constricted Blood Flow.

Authors:  Erik J Carboni; Brice H Bognet; David B Cowles; Anson W K Ma
Journal:  Biophys J       Date:  2018-05-08       Impact factor: 4.033

Review 10.  Flow chamber and microfluidic approaches for measuring thrombus formation in genetic bleeding disorders.

Authors:  Rogier M Schoeman; Marcus Lehmann; Keith B Neeves
Journal:  Platelets       Date:  2017-05-22       Impact factor: 3.862

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.