Literature DB >> 22347762

A Prototype TOF PET Detector Module Using a Micro-Channel Plate Photomultiplier Tube with Waveform Sampling.

H Kim1, C-T Chen, H Frisch, F Tang, C-M Kao.   

Abstract

We are exploring a large area flat panel micro-channel plate photomultiplier tube (MCP PMT) under development for an application to time-of-flight positron emission tomography (TOF PET). High speed waveform sampling with transmission-lines is adopted for reading out the signal with precise time and space information with a small number of low-power channels. As a demonstration of the concept, detector modules have been built using 2″×2″ Photonis Planacon MCP PMTs (XP85022) and prototype transmission-line (TL) boards. The signals from the MCP PMT through the transmission-lines are sampled by DRS4 evaluation boards running at 5 giga-samples per second (GS/s). The event information is extracted by processing the digitized waveforms. For experimental tests, a single 3×3×10 mm(3) LYSO crystal is optically coupled to each MCP PMT; the detector responses to 511 keV annihilation photon from a (22)Na source are measured using the data taken in coincidence mode. As a preliminary result, we obtain a position resolution of ∼2.8 mm (0.3 mm) (FWHM) along (perpendicular to) the transmission-line, ∼309 ps (FWHM) for coincidence time resolution, and ∼14% (FWHM) of energy resolution at 511 keV. This initial result gives a promise that the large area MCP PMT is applicable to TOF PET.

Entities:  

Year:  2012        PMID: 22347762      PMCID: PMC3279923          DOI: 10.1016/j.nima.2011.09.059

Source DB:  PubMed          Journal:  Nucl Instrum Methods Phys Res A        ISSN: 0168-9002            Impact factor:   1.455


  1 in total

1.  A Design of a PET Detector Using Micro-Channel Plate Photomultipliers with Transmission-Line Readout.

Authors:  H Kim; H Frisch; C-T Chen; J-F Genat; F Tang; W W Moses; W S Choong; C-M Kao
Journal:  Nucl Instrum Methods Phys Res A       Date:  2010       Impact factor: 1.455

  1 in total
  4 in total

1.  A feasibility study of a PET/MRI insert detector using strip-line and waveform sampling data acquisition.

Authors:  H Kim; C-T Chen; N Eclov; A Ronzhin; P Murat; E Ramberg; S Los; Alice M Wyrwicz; Limin Li; C-M Kao
Journal:  Nucl Instrum Methods Phys Res A       Date:  2015-06-01       Impact factor: 1.455

2.  A New Time Calibration Method for Switched-capacitor-array-based Waveform Samplers.

Authors:  H Kim; C-T Chen; N Eclov; A Ronzhin; P Murat; E Ramberg; S Los; W Moses; W-S Choong; C-M Kao
Journal:  Nucl Instrum Methods Phys Res A       Date:  2014-12-11       Impact factor: 1.455

3.  An Application of Micro-channel Plate Photomultiplier Tube to Positron Emission Tomography.

Authors:  H Kim; C-T Chen; H Frisch; F Tang; C-M Kao
Journal:  Phys Procedia       Date:  2012

4.  Volumetric High-Resolution X-Ray Phase-Contrast Virtual Histology of Breast Specimens With a Compact Laboratory System.

Authors:  Lorenzo Massimi; Tamara Suaris; Charlotte K Hagen; Marco Endrizzi; Peter R T Munro; Glafkos Havariyoun; P M Sam Hawker; Bennie Smit; Alberto Astolfo; Oliver J Larkin; Richard M Waltham; Zoheb Shah; Stephen W Duffy; Rachel L Nelan; Anthony Peel; J Louise Jones; Ian G Haig; David Bate; Alessandro Olivo
Journal:  IEEE Trans Med Imaging       Date:  2022-05-02       Impact factor: 11.037

  4 in total