Literature DB >> 22340689

Surface treatment by electric discharge machining of Ti-6Al-4V alloy for potential application in orthopaedics.

Petr Harcuba1, Lucie Bačáková, Josef Stráský, Markéta Bačáková, Katarína Novotná, Miloš Janeček.   

Abstract

This study investigated the properties of Ti-6Al-4V alloy after surface treatment by the electric discharge machining (EDM) process. The EDM process with high peak currents proved to induce surface macro-roughness and to cause chemical changes to the surface. Evaluations were made of the mechanical properties by means of tensile tests, and of surface roughness for different peak currents of the EDM process. The EDM process with peak current of 29 A was found to induce sufficient surface roughness, and to have a low adverse effect on tensile properties. The chemical changes were studied by scanning electron microscopy equipped with an energy dispersive X-ray analyser (EDX). The surface of the benchmark samples was obtained by plasma-spraying a titanium dioxide coating. An investigation of the biocompatibility of the surface-treated Ti-6Al-4V samples in cultures of human osteoblast-like MG 63 cells revealed that the samples modified by EDM provided better substrates for the adhesion, growth and viability of MG 63 cells than the TiO2 coated surface. Thus, EDM treatment can be considered as a promising surface modification to orthopaedic implants, in which good integration with the surrounding bone tissue is required. Copyright Â
© 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22340689     DOI: 10.1016/j.jmbbm.2011.07.001

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  5 in total

Review 1.  A comprehensive review on metallic implant biomaterials and their subtractive manufacturing.

Authors:  Rahul Davis; Abhishek Singh; Mark James Jackson; Reginaldo Teixeira Coelho; Divya Prakash; Charalambos Panayiotou Charalambous; Waqar Ahmed; Leonardo Rosa Ribeiro da Silva; Abner Ankit Lawrence
Journal:  Int J Adv Manuf Technol       Date:  2022-02-23       Impact factor: 3.563

2.  Growth and potential damage of human bone-derived cells cultured on fresh and aged C60/Ti films.

Authors:  Ivana Kopova; Vasily Lavrentiev; Jiri Vacik; Lucie Bacakova
Journal:  PLoS One       Date:  2015-04-15       Impact factor: 3.240

3.  Effect of Electrical Discharge Machining on Stress Concentration in Titanium Alloy Holes.

Authors:  Wei-Hsuan Hsu; Wan-Ting Chien
Journal:  Materials (Basel)       Date:  2016-11-24       Impact factor: 3.623

4.  EDM of Ti-6Al-4V under Nano-Graphene Mixed Dielectric: A Detailed Investigation on Axial and Radial Dimensional Overcuts.

Authors:  Kashif Ishfaq; Muhammad Asad; Muhammad Harris; Abdullah Alfaify; Saqib Anwar; Luciano Lamberti; Maria Luminita Scutaru
Journal:  Nanomaterials (Basel)       Date:  2022-01-27       Impact factor: 5.076

Review 5.  Surface Modification Techniques to Produce Micro/Nano-scale Topographies on Ti-Based Implant Surfaces for Improved Osseointegration.

Authors:  Chuang Hou; Jing An; Duoyi Zhao; Xiao Ma; Weilin Zhang; Wei Zhao; Meng Wu; Zhiyu Zhang; Fusheng Yuan
Journal:  Front Bioeng Biotechnol       Date:  2022-03-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.