Abstract

BACKGROUND: Proper rotational alignment during total knee arthroplasty (TKA) is important for adequate postoperative patellofemoral and tibiofemoral kinematics, as well as for achieving balanced flexion space at 90. The effects of computer navigation-assisted total knee replacement and conventional total knee arthroplasty on rotational alignment, mechanical axis, component position and clinical outcomes were compared.
METHODS: Two methods were used in 82 patients and the rotation of the femoral and tibial components in the transverse plane, the combined rotation of the two components, the mismatch between them, and the mechanical axis of the lower limb were analyzed. All of these parameters were measured from postoperative radiographs and computed tomography images. Functional outcomes were compared at 6 weeks and 6 months postoperatively.
RESULTS: Significant differences were found between the two techniques (P < 0.05) in the following parameters: average rotation of the femoral component ((1.51 ± 3.55)° vs. (-0.63 ± 3.04)°); combined rotation of the femoral and tibial components (2.85 ± 4.07)° vs. (0.28 ± 3.43)°); and mismatch between the femoral and tibial components ((1.44 ± 4.55)° vs. (-0.43 ± 2.86)°). Differences in the rotation of the tibial component were not statistically significant. The prevalence of outliers (malalignment > ± 3° internal/external rotation) of the femoral component (31.7% vs. 12.5%) and the tibial component (36.6% vs. 15%) were significantly reduced when the navigation system was used (P < 0.05). In addition, while patients in the navigation group had significantly better mechanical axis and functional outcomes at 6 weeks after surgery (P < 0.05), there was no significant difference between the two groups (P > 0.05) with respect to functional outcomes at 6 months.
CONCLUSION: The navigation system exhibited higher accuracy than the conventional technique in the transverse and coronal plane, and provided better early functional outcomes.

Entities:  

Mesh:

Year:  2012        PMID: 22340552

Source DB:  PubMed          Journal:  Chin Med J (Engl)        ISSN: 0366-6999            Impact factor:   2.628


  8 in total

Review 1.  Computer Assisted Total Knee Arthroplasty: Does it Make a Difference?

Authors:  Emil G Haritinian; Ashvin L Pimpalnerkar
Journal:  Maedica (Buchar)       Date:  2013-06

2.  External rotation of the femoral component decreases patellofemoral contact stress in total knee arthroplasty.

Authors:  Takashi Terashima; Tomohiro Onodera; Naohiro Sawaguchi; Yasuhiko Kasahara; Tokifumi Majima
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-11       Impact factor: 4.342

3.  Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian population).

Authors:  Mahmoud Jabalameli; Amin Moradi; Abolfazl Bagherifard; Mehran Radi; Tahmineh Mokhtari
Journal:  Arch Bone Jt Surg       Date:  2016-04

Review 4.  Does imageless computer-assisted TKA lead to improved rotational alignment or fewer outliers? A systematic review.

Authors:  Marrigje F Meijer; Inge H F Reininga; Alexander L Boerboom; Sjoerd K Bulstra; Martin Stevens
Journal:  Clin Orthop Relat Res       Date:  2014-05-28       Impact factor: 4.176

5.  Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement.

Authors:  Andrea Ensini; Antonio Timoncini; Francesco Cenni; Claudio Belvedere; Francesca Fusai; Alberto Leardini; Sandro Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-24       Impact factor: 4.342

Review 6.  Effect of rotational alignment on outcome of total knee arthroplasty.

Authors:  Kars P Valkering; Stefan J Breugem; Michel Pj van den Bekerom; Willem E Tuinebreijer; Rutger C I van Geenen
Journal:  Acta Orthop       Date:  2015-02-24       Impact factor: 3.717

7.  Computed Tomographic measurement of distal femor rotation in Iranian population.

Authors:  Mehdi Moghtadaei; Javad Moghimi; Gholamreza Shahhoseini
Journal:  Med J Islam Repub Iran       Date:  2015-01-28

8.  The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty.

Authors:  Kwangkyoun Kim; Jungsung Kim; Dokyoung Lee; Sohui Lim; Jiyoon Eom
Journal:  Knee Surg Relat Res       Date:  2019-03-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.