Literature DB >> 22336039

Accuracy of intraocular lens power calculation formulae in children less than two years.

Ramesh Kekunnaya1, Amit Gupta, Virender Sachdeva, Harsha L Rao, Pravin K Vaddavalli, Vempati Om Prakash.   

Abstract

PURPOSE: To assess the accuracy of IOL power calculation formulae in children less than 2 years of age.
DESIGN: Retrospective, comparative study, comprising of 128 eyes of 84 children.
METHODS: We analyzed records of children less than 2 years with congenital cataract who underwent primary IOL implantation. Data were analyzed for prediction error using the 4 commonly used IOL power calculation formulae. We calculated the absolute prediction error with each of the formulae and the formula that gave least variability was determined. The formula that gave the best prediction error was determined.
RESULTS: Mean age at surgery was 11.7 ± 6.2 months. Absolute prediction error was found to be 2.27 ± 1.69 diopters (D) with SRK II, 3.23 ± 2.24 D with SRK T, 3.62 ± 2.42 D with Holladay, and 4.61 ± 3.12 D with Hoffer Q. The number of eyes with absolute prediction error within 0.5 D was 27 (21.1%) with SRK II, 8 (6.3%) with SRK T, 12 (9.4%) with Holladay, and 5 (3.9%) with Hoffer Q. Comparison between different formulae showed that the absolute prediction error with SRK II formula was significantly better than with other formulae (P < .001). Prediction error with SRK II formula was not affected by any factor such as age (P = .31), keratometry (P = .32), and axial length (P = .27) of the patient. Axial length influenced the absolute prediction error with Holladay (P = .05) and Hoffer Q formulae (P = .002). Mean keratometry influenced prediction error (P = .03) with SRK T formula.
CONCLUSION: Although absolute prediction error tends to remain high with all present IOL power calculation formulae, SRK II was the most predictable formula in our series.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22336039     DOI: 10.1016/j.ajo.2011.11.031

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  19 in total

1.  Predictability of intraocular lens power calculation formulae in infantile eyes with unilateral congenital cataract: results from the Infant Aphakia Treatment Study.

Authors:  Deborah K Vanderveen; Rupal H Trivedi; Azhar Nizam; Michael J Lynn; Scott R Lambert
Journal:  Am J Ophthalmol       Date:  2013-09-04       Impact factor: 5.258

2.  Comparison of IOL power calculation formulae for pediatric eyes.

Authors:  V Vasavada; S K Shah; V A Vasavada; A R Vasavada; R H Trivedi; S Srivastava; S A Vasavada
Journal:  Eye (Lond)       Date:  2016-08-05       Impact factor: 3.775

3.  Second intraocular surgery after primary pediatric cataract surgery: indications and outcomes during long-term follow-up at a tertiary eye care center.

Authors:  V Sachdeva; S Katukuri; MdH Ali; R Kekunnaya
Journal:  Eye (Lond)       Date:  2016-07-29       Impact factor: 3.775

4.  Accuracy of 8 intraocular lens power calculation formulas in pediatric cataract patients.

Authors:  Pingjun Chang; Lei Lin; Zhangliang Li; Li Wang; Jinhai Huang; Yun-E Zhao
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-02-17       Impact factor: 3.117

5.  Challenges in pediatric cataract surgery: comparison of intraocular lens power calculation formulas using optical biometry.

Authors:  İbrahim Edhem Yılmaz; Sabit Kimyon; Alper Mete
Journal:  Int Ophthalmol       Date:  2022-04-01       Impact factor: 2.029

6.  Ocular Component Development during Infancy and Early Childhood.

Authors:  Donald O Mutti; Loraine T Sinnott; G Lynn Mitchell; Lisa A Jordan; Nina E Friedman; Sara L Frane; Wendy K Lin
Journal:  Optom Vis Sci       Date:  2018-11       Impact factor: 1.973

Review 7.  Pediatric cataract: challenges and future directions.

Authors:  Anagha Medsinge; Ken K Nischal
Journal:  Clin Ophthalmol       Date:  2015-01-07

8.  The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas.

Authors:  Jinho Jeong; Han Song; Jimmy K Lee; Roy S Chuck; Ji-Won Kwon
Journal:  BMC Ophthalmol       Date:  2017-05-02       Impact factor: 2.209

9.  Accuracy of formulae for secondary intraocular lens power calculations in pediatric aphakia.

Authors:  Fouad R Nakhli; Khaled Emarah; Laila Jeddawi
Journal:  J Curr Ophthalmol       Date:  2017-06-13

10.  Distribution of Axial Length before Cataract Surgery in Chinese Pediatric Patients.

Authors:  Haotian Lin; Duoru Lin; Jingjing Chen; Lixia Luo; Zhuoling Lin; Xiaohang Wu; Erping Long; Li Zhang; Hui Chen; Wan Chen; Bo Zhang; Jinchao Liu; Xiaoyan Li; Weirong Chen; Yizhi Liu
Journal:  Sci Rep       Date:  2016-03-29       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.