Literature DB >> 22335883

Microbial environmental contamination in Italian dental clinics: A multicenter study yielding recommendations for standardized sampling methods and threshold values.

Cesira Pasquarella1, Licia Veronesi, Christian Napoli, Paolo Castiglia, Giorgio Liguori, Rolando Rizzetto, Ida Torre, Elena Righi, Patrizia Farruggia, Marina Tesauro, Maria V Torregrossa, Maria T Montagna, Maria E Colucci, Francesca Gallè, Maria D Masia, Laura Strohmenger, Margherita Bergomi, Carola Tinteri, Manuela Panico, Francesca Pennino, Lucia Cannova, Marialuisa Tanzi.   

Abstract

A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and for the different sampling times. Before clinical activity, microbial water contamination in tap water reached 51,200cfu/mL (colony forming units per milliliter), and that in Dental Unit Water Systems (DUWSs) reached 872,000cfu/mL. After clinical activity, there was a significant decrease in the Total Viable Count (TVC) in tap water and in DUWSs. Pseudomonas aeruginosa was found in 2.38% (7/294) of tap water samples and in 20.06% (59/294) of DUWS samples; Legionella spp. was found in 29.96% (89/297) of tap water samples and 15.82% (47/297) of DUWS samples, with no significant difference between pre- and post-clinical activity. Microbial air contamination was highest during dental treatments, and decreased significantly at the end of the working activity (p<0.05). The microbial buildup on surfaces increased significantly during the working hours. This study provides data for the establishment of standardized sampling methods, and threshold values for contamination monitoring in dentistry. Some very critical situations have been observed which require urgent intervention. Furthermore, the study emphasizes the need for research aimed at defining effective managing strategies for dental clinics. Copyright Â
© 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22335883     DOI: 10.1016/j.scitotenv.2012.01.030

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  17 in total

Review 1.  A scoping review on bio-aerosols in healthcare and the dental environment.

Authors:  Charifa Zemouri; Hans de Soet; Wim Crielaard; Alexa Laheij
Journal:  PLoS One       Date:  2017-05-22       Impact factor: 3.240

2.  Microbial contamination of dental unit waterlines and effect on quality of indoor air.

Authors:  Duygu Göksay Kadaifciler; Aysin Cotuk
Journal:  Environ Monit Assess       Date:  2014-01-28       Impact factor: 2.513

3.  TREM2 Acts Downstream of CD33 in Modulating Microglial Pathology in Alzheimer's Disease.

Authors:  Ana Griciuc; Shaun Patel; Anthony N Federico; Se Hoon Choi; Brendan J Innes; Mary K Oram; Gea Cereghetti; Danielle McGinty; Anthony Anselmo; Ruslan I Sadreyev; Suzanne E Hickman; Joseph El Khoury; Marco Colonna; Rudolph E Tanzi
Journal:  Neuron       Date:  2019-07-10       Impact factor: 17.173

4.  Occurrence and biofilm forming ability of Pseudomonas aeruginosa in the water output of dental unit waterlines in a dental center in Alexandria, Egypt.

Authors:  Sheref Gawish; Aleya Abbass; Amani Abaza
Journal:  Germs       Date:  2019-06-03

5.  Impact of a risk management plan on Legionella contamination of dental unit water.

Authors:  Erica Leoni; Laura Dallolio; Francesca Stagni; Tiziana Sanna; Giovanni D'Alessandro; Gabriela Piana
Journal:  Int J Environ Res Public Health       Date:  2015-02-23       Impact factor: 3.390

6.  Occupational risk for Legionella infection among dental healthcare workers: meta-analysis in occupational epidemiology.

Authors:  Stefano Petti; Matteo Vitali
Journal:  BMJ Open       Date:  2017-07-13       Impact factor: 2.692

7.  Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

Authors:  Maria Teresa Montagna; Osvalda De Giglio; Maria Luisa Cristina; Christian Napoli; Claudia Pacifico; Antonella Agodi; Tatjana Baldovin; Beatrice Casini; Maria Anna Coniglio; Marcello Mario D'Errico; Santi Antonino Delia; Maria Grazia Deriu; Marco Guida; Pasqualina Laganà; Giorgio Liguori; Matteo Moro; Ida Mura; Francesca Pennino; Gaetano Privitera; Vincenzo Romano Spica; Silvia Sembeni; Anna Maria Spagnolo; Stefano Tardivo; Ida Torre; Federica Valeriani; Roberto Albertini; Cesira Pasquarella
Journal:  Int J Environ Res Public Health       Date:  2017-06-22       Impact factor: 3.390

8.  Prevention and Control of Legionella and Pseudomonas spp. Colonization in Dental Units.

Authors:  Benedetta Tuvo; Michele Totaro; Maria Luisa Cristina; Anna Maria Spagnolo; David Di Cave; Sara Profeti; Angelo Baggiani; Gaetano Privitera; Beatrice Casini
Journal:  Pathogens       Date:  2020-04-21

9.  An Evaluation of Two Systems for the Management of the Microbiological Quality of Water in Dental Unit Waterlines: Hygowater® and IGN Calbénium®.

Authors:  Damien Offner; Anne-Marie Musset
Journal:  Int J Environ Res Public Health       Date:  2021-05-20       Impact factor: 3.390

10.  Effect of different disinfection protocols on microbial and biofilm contamination of dental unit waterlines in community dental practices.

Authors:  Laura Dallolio; Amalia Scuderi; Maria S Rini; Sabrina Valente; Patrizia Farruggia; Maria A Bucci Sabattini; Gianandrea Pasquinelli; Anna Acacci; Greta Roncarati; Erica Leoni
Journal:  Int J Environ Res Public Health       Date:  2014-02-18       Impact factor: 3.390

View more