Literature DB >> 2233377

Evaluation of ECG interpretation results obtained by computer and cardiologists.

J L Willems1, C Abreu-Lima, P Arnaud, C R Brohet, B Denis, J Gehring, I Graham, G van Herpen, H Machado, J Michaelis.   

Abstract

In an international project investigators from 25 institutes are trying to establish a common reference library and evaluation methods for testing the diagnostic performance of various ECG computer programs and of cardiologists, based on ECG-independent clinical information. A first set of 500 validated ECGs was collected and analyzed by fifteen different computer programs and nine cardiologists, seven of who analysed the ECG and five the VCG. A coding scheme was used to map individual diagnostic statements onto a common set. Combined program and referee results were obtained by weighted averaging. Preliminary results indicate that the classification accuracy of several programs can still be improved. However, it was also apparent that the results of the best 12-lead ECG computer programs proved to be almost as accurate as the best of seven cardiologists in classifying seven main disease categories, i.e., normal, left, right and biventricular hypertrophy, anterior, inferior and combined myocardial infarction. Evaluation of rhythm statements and conduction disturbances was not included in the study. The data collection is still being pursued in order to reach over 1,000 cases. In this way a common diagnostic database is being established for comparative testing of diagnostic computer programs. This should lead to consumer protection and improve the accuracy and reliability of computerized electrocardiography.

Entities:  

Mesh:

Year:  1990        PMID: 2233377

Source DB:  PubMed          Journal:  Methods Inf Med        ISSN: 0026-1270            Impact factor:   2.176


  5 in total

1.  Reference standards, judges, and comparison subjects: roles for experts in evaluating system performance.

Authors:  George Hripcsak; Adam Wilcox
Journal:  J Am Med Inform Assoc       Date:  2002 Jan-Feb       Impact factor: 4.497

Review 2.  Medical diagnostic decision support systems--past, present, and future: a threaded bibliography and brief commentary.

Authors:  R A Miller
Journal:  J Am Med Inform Assoc       Date:  1994 Jan-Feb       Impact factor: 4.497

3.  Diagnostic accuracy of left ventricular hypertrophy in patients with myocardial infarction by computer-assisted electrocardiography (ELECTROPRES).

Authors:  Luis Rodríguez-Padial; Finn Akerström; Carolina Robles-Gamboa; Josep Andrés; Jessica Ruiz-Baena
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-11-22       Impact factor: 1.468

4.  The effect of erroneous computer interpretation of ECGs on resident decision making.

Authors:  William N Southern; Julia Hope Arnsten
Journal:  Med Decis Making       Date:  2009-05-21       Impact factor: 2.583

5.  Progression of Renal Insufficiency in Patients with Essential Hypertension Treated with Renin Angiotensin Aldosterone System Blockers: An Electrocardiographic Correlation.

Authors:  Luis Rodriguez-Padial; Finn Akerström; María G Barderas; Fernando Vivanco; Miguel A Arias; Julian Segura; Luis M Ruilope
Journal:  Diseases       Date:  2017-12-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.