Literature DB >> 22330545

Enhancement of photoacoustic image quality by sound speed correction: ex vivo evaluation.

Changhan Yoon1, Jeeun Kang, Seunghee Han, Yangmo Yoo, Tai-Kyong Song, Jin Ho Chang.   

Abstract

Real-time photoacoustic (PA) imaging involves beamforming methods using an assumed fixed sound speed, typically 1540 m/s in soft tissue. This leads to degradation of PA image quality because the true sound speed changes as PA signal propagates through different types of soft tissues: the range from 1450 m/s to 1600 m/s. This paper proposes a new method for estimating an optimal sound speed to enhance the cross-sectional PA image quality. The optimal sound speed is determined when coherent factor with the sound speed is maximized. The proposed method was validated through simulation and ex vivo experiments with microcalcification-contained breast cancer specimen. The experimental results demonstrated that the best lateral resolution of PA images of microcalcifications can be achieved when the optimal sound speed is utilized.

Entities:  

Mesh:

Year:  2012        PMID: 22330545     DOI: 10.1364/OE.20.003082

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  11 in total

1.  Initial phantom study on estimation of speed of sound in medium using coherence among received echo signals.

Authors:  Hideyuki Hasegawa; Ryo Nagaoka
Journal:  J Med Ultrason (2001)       Date:  2019-03-08       Impact factor: 1.314

Review 2.  Photoacoustic assessment of the fetal brain and placenta as a method of non-invasive antepartum and intrapartum monitoring.

Authors:  Jeeun Kang; Raymond C Koehler; Ernest M Graham; Emad M Boctor
Journal:  Exp Neurol       Date:  2021-10-15       Impact factor: 5.330

3.  Elevational Synthetic Aperture Focusing for Three-Dimensional Photoacoustic Imaging Using a Clinical One-Dimensional Array Transducer.

Authors:  Changhan Yoon; Jeeun Kang; Tai-Kyong Song; Jin Ho Chang
Journal:  IEEE Trans Biomed Eng       Date:  2022-08-19       Impact factor: 4.756

4.  Synchronization of RF Data in Ultrasound Open Platforms (UOPs) for High-Accuracy and High-Resolution Photoacoustic Tomography Using the "Scissors" Programming Method.

Authors:  Lei Fu; Zhicheng Jin; Baiyan Qi; Wonjun Yim; Zhuohong Wu; Tengyu He; Jesse V Jokerst
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-05-26       Impact factor: 3.267

5.  Photoacoustic imaging of breast microcalcifications: a preliminary study with 8-gauge core-biopsied breast specimens.

Authors:  Ga Ram Kim; Jeeun Kang; Jin Young Kwak; Jin Ho Chang; Seung Il Kim; Ji Hyun Youk; Hee Jung Moon; Min Jung Kim; Eun-Kyung Kim
Journal:  PLoS One       Date:  2014-08-25       Impact factor: 3.240

6.  Imaging acoustic sources through scattering media by using a correlation full-matrix filter.

Authors:  Wei Rui; Chao Tao; Xiaojun Liu
Journal:  Sci Rep       Date:  2018-10-23       Impact factor: 4.379

7.  Transrectal Ultrasound and Photoacoustic Imaging Probe for Diagnosis of Prostate Cancer.

Authors:  Jihun Jang; Jinwoo Kim; Hak Jong Lee; Jin Ho Chang
Journal:  Sensors (Basel)       Date:  2021-02-09       Impact factor: 3.576

Review 8.  Advances in ultrasonography: image formation and quality assessment.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2021-10-20       Impact factor: 1.314

9.  Improving image quality by accounting for changes in water temperature during a photoacoustic tomography scan.

Authors:  Dominique Van de Sompel; Laura Sarah Sasportas; Anca Dragulescu-Andrasi; Sarah Bohndiek; Sanjiv Sam Gambhir
Journal:  PLoS One       Date:  2012-10-11       Impact factor: 3.240

10.  Impact of depth-dependent optical attenuation on wavelength selection for spectroscopic photoacoustic imaging.

Authors:  Heechul Yoon; Geoffrey P Luke; Stanislav Y Emelianov
Journal:  Photoacoustics       Date:  2018-10-09
View more