Literature DB >> 22327451

Taylor spatial frame in the treatment of upper extremity conditions.

Mohammed J Al-Sayyad1.   

Abstract

BACKGROUND: Taylor spatial frame (TSF) is a modern multiplanar external fixator that combines ease of application and computer accuracy; it provides the capability of 1 to 6 axes of deformity correction sequentially or simultaneously by adjusting 6 connecting struts between 2 circular rings. Previous reports have documented the effectiveness of the TSF in acute fracture care, nonunion treatment, and in bone lengthening and deformity correction in the lower extremity. To the authors' knowledge, no previous case series in the English literature have documented the use of the TSF in treating upper extremity conditions. Our experience with the use of this external fixator in the treatment of upper extremity length abnormality, angulation, and bone transport is summarized.
METHODS: Over a period of 7 years, TSF was used in 12 patients with varying upper extremity pathologies that were collected from our prospective external fixator database. The classic TSF planning strategy was adopted and the TSF web-based program was used. All cases were followed for a minimum of 2 years. The database and radiographs were reviewed to obtain demographic data, malalignment parameters, final correction, time in the TSF, and complications. RESULT: Patients' ages ranged from 8 to 18 years. Eight humeral and 4 radial cases were identified. These included 4 cubitus varus and 1 cubitus valgus deformity, 1 neglected supracondylar fracture, 2 humeral nonunion, 2 radial malunion cases, and 1 radial shaft septic nonunion. Time in the TSF varied according to patient age and bone involved. Five patients had superficial pin site infections that resolved with oral antibiotics. Postoperatively mean final angulation on the anteroposterior radiograph was 1 degree (range, 0 to 5 degrees) and the mean final angulation on the lateral radiograph was 0.5 degrees (range, 0 to 2 degrees). Union of bone was achieved in all cases.
CONCLUSIONS: The TSF is an external fixator that can be successfully used as a treatment alternative for the definitive treatment of upper extremity conditions involving a deformity and or shortening or bone transport in the pediatric and adolescent patient population. LEVEL OF EVIDENCE: Level IV.

Entities:  

Mesh:

Year:  2012        PMID: 22327451     DOI: 10.1097/BPO.0b013e3182471ae4

Source DB:  PubMed          Journal:  J Pediatr Orthop        ISSN: 0271-6798            Impact factor:   2.324


  6 in total

1.  Humerus Lengthening: A Comparison of the Internal Lengthening Nail to External Fixation.

Authors:  Sherif Galal; Jonggu Shin; Peter Principe; Rena Mehta; Nathan Khabyeh-Hasbani; Amber Hamilton; Austin Fragomen; S Robert Rozbruch
Journal:  HSS J       Date:  2021-03-04

2.  Humeral Lengthening with the PRECICE Magnetic Lengthening Nail.

Authors:  Ahmed I Hammouda; Shawn C Standard; S Robert Rozbruch; John E Herzenberg
Journal:  HSS J       Date:  2017-04-21

3.  [Posttraumatic complications on children's elbows].

Authors:  T Kraus; S Tauber; W Linhart
Journal:  Orthopade       Date:  2013-01       Impact factor: 1.087

4.  Treatment of post-traumatic elbow deformities in children with the Ilizarov distraction osteogenesis technique.

Authors:  Cenk Özkan; Mehmet Ali Deveci; Mustafa Tekin; Ömer Sunkar Biçer; Kadir Gökçe; Mahir Gülşen
Journal:  Acta Orthop Traumatol Turc       Date:  2016-10-17       Impact factor: 1.511

5.  Age-related Outcomes and Complications of Osteodistraction in the Pediatric Upper Extremity: A Large Retrospective Single-center Study of 61 Cases.

Authors:  Philipp Scheider; Rudolf Ganger; Sebastian Farr
Journal:  J Pediatr Orthop       Date:  2022-02-01       Impact factor: 2.324

6.  Calcium phosphate bone cement and metaphyseal -corrective osteotomies in the upper extremity: long-term follow-up of 10 children.

Authors:  Mona I Winge; Magne Røkkum
Journal:  Acta Orthop       Date:  2022-09-23       Impact factor: 3.925

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.