Literature DB >> 22324874

An assessment of the accuracy of pulse oximeters.

Q J W Milner1, G R Mathews.   

Abstract

Peripheral pulse oximetry has become a core monitoring modality in most fields of medicine. Pulse oximeters are used ubiquitously in operating theatres, hospital wards, outpatient clinics and general practice surgeries. This study used a portable spectrometer (Lightman(®), The Electrode Co. Ltd., Monmouthshire, UK) to measure the emission spectra of the two light emitting diodes within the pulse oximeter sensor and to determine the accuracy of 847 pulse oximeters currently in use in 29 NHS hospitals in the UK. The standard manufacturing claim of accuracy for pulse oximeters is ± 2-3% over the range of 70-100% S(p)O(2). Eighty-nine sensors (10.5%) were found to have a functional error of their electrical circuitry that could cause inaccuracy of measurement. Of the remaining 758 sensors, 169 (22.3%) were found to have emission spectra different from the manufacturers' specification that would cause an inaccuracy in saturation estimation of > 4% in the range of 70-100% saturation. This study has demonstrated that a significant proportion of pulse oximeter sensors may be inaccurate. Anaesthesia
© 2012 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Year:  2012        PMID: 22324874     DOI: 10.1111/j.1365-2044.2011.07021.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  15 in total

1.  Experimental system for measuring the full scattering profile of circular phantoms.

Authors:  Idit Feder; Hamootal Duadi; Dror Fixler
Journal:  Biomed Opt Express       Date:  2015-07-14       Impact factor: 3.732

2.  Clinical Interpretation of Peripheral Pulse Oximeters Labeled "Not for Medical Use".

Authors:  Arlene J Hudson; John Benjamin; Timothy Jardeleza; Curt Bergstrom; William Cronin; Mario Mendoza; Lex Schultheis
Journal:  Ann Fam Med       Date:  2018-11       Impact factor: 5.166

3.  Changes in CO-oximetry values and pulse oximetry in isoflurane-anesthetized dogs with and without nitrous oxide.

Authors:  Teela Jones; Cindy Feng; Tanya Duke-Novakovski
Journal:  Can J Vet Res       Date:  2020-04       Impact factor: 1.310

4.  Pulse oximetry in primary care: factors affecting accuracy and interpretation.

Authors:  Paul Silverston; Marco Ferrari; Valentina Quaresima
Journal:  Br J Gen Pract       Date:  2022-02-24       Impact factor: 5.386

Review 5.  Hemoglobin oxygen saturation targets in the neonatal intensive care unit: Is there a light at the end of the tunnel? 1.

Authors:  Payam Vali; Mark Underwood; Satyan Lakshminrusimha
Journal:  Can J Physiol Pharmacol       Date:  2018-10-26       Impact factor: 2.273

6.  Non-contact measurement of oxygen saturation with an RGB camera.

Authors:  Alessandro R Guazzi; Mauricio Villarroel; João Jorge; Jonathan Daly; Matthew C Frise; Peter A Robbins; Lionel Tarassenko
Journal:  Biomed Opt Express       Date:  2015-08-11       Impact factor: 3.732

Review 7.  Oxygen targeting in preterm infants: a physiological interpretation.

Authors:  S Lakshminrusimha; V Manja; B Mathew; G K Suresh
Journal:  J Perinatol       Date:  2014-10-30       Impact factor: 2.521

8.  Smoothing Effect in Vital Sign Recordings: Fact or Fiction? A Retrospective Cohort Analysis of Manual and Continuous Vital Sign Measurements to Assess Data Smoothing in Postoperative Care.

Authors:  Hamish R Tomlinson; Marco A F Pimentel; Stephen Gerry; David A Clifton; Lionel Tarassenko; Peter J Watkinson
Journal:  Anesth Analg       Date:  2018-10       Impact factor: 5.108

9.  The Relationship Between Oxygen Reserve Index and Arterial Partial Pressure of Oxygen During Surgery.

Authors:  Richard L Applegate; Ihab L Dorotta; Briana Wells; David Juma; Patricia M Applegate
Journal:  Anesth Analg       Date:  2016-09       Impact factor: 5.108

10.  Source-Detector Spectral Pairing-Related Inaccuracies in Pulse Oximetry: Evaluation of the Wavelength Shift.

Authors:  Olivier Tsiakaka; Benoit Gosselin; Sylvain Feruglio
Journal:  Sensors (Basel)       Date:  2020-06-10       Impact factor: 3.576

View more