Literature DB >> 22323618

Informatics in radiology: postprocessing pitfalls in using CT for automatic and semiautomatic determination of global left ventricular function.

Peter M A van Ooijen1, Gonda J de Jonge, Matthys Oudkerk.   

Abstract

Recent advances in technical capabilities of computed tomographic (CT) scanners, including an increasing number of detector rows, improved spatial and temporal resolution, and the development of retrospective gating, have allowed the acquisition of four-dimensional (4D) datasets of the beating heart. As a result, the heart can be visualized in different phases and CT datasets can be used to assess cardiac function. Many software packages currently exist that allow automatic or semiautomatic evaluation of left ventricular function on the basis of 4D CT datasets. The level of automation varies from extensive, completely manual segmentation by the user to fully automatic evaluation of left ventricular function without any user interaction. Although the reproducibility of functional parameter assessment is reported to be high and intersoftware variability low for larger groups of patients, significant differences can exist among measurements obtained with different software tools from the same dataset. Thus, careful review of automatically or semiautomatically obtained results is required. © RSNA, 2012.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22323618     DOI: 10.1148/rg.322115058

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  6 in total

1.  Semiautomatic three-dimensional CT ventricular volumetry in patients with congenital heart disease: agreement between two methods with different user interaction.

Authors:  Hyun Woo Goo; Sang-Hyub Park
Journal:  Int J Cardiovasc Imaging       Date:  2015-08-29       Impact factor: 2.357

2.  Left ventricle volume measured by cardiac CT in an infant with a small left ventricle: a new and accurate method in determining uni- or biventricular repair.

Authors:  Ho Jin Kim; Hyun Woo Goo; Sang-Hyub Park; Tae-Jin Yun
Journal:  Pediatr Radiol       Date:  2012-08-09

Review 3.  Comparison of Echocardiography, Cardiac Magnetic Resonance, and Computed Tomographic Imaging for the Evaluation of Left Ventricular Myocardial Function: Part 1 (Global Assessment).

Authors:  Menhel Kinno; Prashant Nagpal; Stephen Horgan; Alfonso H Waller
Journal:  Curr Cardiol Rep       Date:  2017-01       Impact factor: 2.931

Review 4.  Role of cardiac CTA in estimating left ventricular volumes and ejection fraction.

Authors:  Robin Man Singh; Balkrishna Man Singh; Jawahar Lal Mehta
Journal:  World J Radiol       Date:  2014-09-28

5.  Semiautomatic Three-Dimensional Threshold-Based Cardiac Computed Tomography Ventricular Volumetry in Repaired Tetralogy of Fallot: Comparison with Cardiac Magnetic Resonance Imaging.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2018-12-27       Impact factor: 3.500

6.  Comparison between Three-Dimensional Navigator-Gated Whole-Heart MRI and Two-Dimensional Cine MRI in Quantifying Ventricular Volumes.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2018-06-14       Impact factor: 3.500

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.