Can volumetric modulated arc therapy with flattening filter free beams play a role in stereotactic body radiotherapy for liver lesions? A volume-based analysis.

Giacomo Reggiori1, Pietro Mancosu, Simona Castiglioni, Filippo Alongi, Chiara Pellegrini, Francesca Lobefalo, Maddalena Catalano, Antonella Fogliata, Stefano Arcangeli, Piera Navarria, Luca Cozzi, Marta Scorsetti.   

Abstract

PURPOSE: To compare volumetric modulated arc therapy with flattening filter free (FFF) and flattening filter (FF) beams in patients with hepatic metastases subject to hypofractionated radiotherapy (RT).
METHODS: A planning study on 13 virtual lesions of increasing volume was performed. Two single arc plans were optimized with the RapidArc technique using either FFF or FF beams. A second planning study was performed on ten patients treated for liver metastases to validate conclusions. In all cases, a dose of 75 Gy in 3 fractions was prescribed to the planning target volume (PTV) and plans were evaluated in terms of coverage, homogeneity, conformity, mean dose to healthy liver and to healthy tissue. For each parameter, results were expressed in relative terms as the percentage ratio between FFF and FF data.
RESULTS: In terms of PTV coverage, conformity index favored FFF for targets of intermediate size while FF resulted more suitable for small (<100 cm(3)) and large (>300 cm(3)) targets. Plans optimized with FFF beams resulted in increased sparing of healthy tissue in ≈85% of cases. Despite the qualitative results, no statistically significant differences were found between FFF and FF results. Plans optimized with un-flattened beams resulted in higher average MU∕Gy than plans with FF beams. A remarkable and significant difference was observed in the beam-on time (BOT) needed to deliver plans. The BOT for FF plans was 8.2 ± 1.0 min; for FFF plans BOT was 2.2 ± 0.2 min.
CONCLUSIONS: RapidArc plans optimized using FFF were dosimetrically equivalent to those optimized using FF beams, showing the feasibility of SBRT treatments with FFF beams. Some improvement in healthy tissue sparing was observed when using the FFF modality due to the different beam's profile. The main advantage was a considerable reduction of beam-on time, relevant for SBRT techniques.

Entities:  

Mesh:

Year:  2012        PMID: 22320821     DOI: 10.1118/1.3679858

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  Volumetric-modulated arc stereotactic body radiotherapy for prostate cancer: dosimetric impact of an increased near-maximum target dose and of a rectal spacer.

Authors:  Ruggero Ruggieri; Stefania Naccarato; Pavel Stavrev; Nadejda Stavreva; Sergio Fersino; Niccolò Giaj Levra; Rosario Mazzola; Pietro Mancosu; Marta Scorsetti; Filippo Alongi
Journal:  Br J Radiol       Date:  2015-08-03       Impact factor: 3.039

2.  Stereotactic ablative radiation therapy for brain metastases with volumetric modulated arc therapy and flattening filter free delivery: feasibility and early clinical results.

Authors:  Alba Fiorentino; Niccolò Giaj-Levra; Umberto Tebano; Rosario Mazzola; Francesco Ricchetti; Sergio Fersino; Gioacchino Di Paola; Dario Aiello; Ruggero Ruggieri; Filippo Alongi
Journal:  Radiol Med       Date:  2017-04-26       Impact factor: 3.469

3.  Initial experience of hypofractionated radiation retreatment with true beam and flattening filter free beam in selected case reports of recurrent nasopharyngeal carcinoma.

Authors:  Filippo Alongi; Elena Clerici; Sara Pentimalli; Pietro Mancosu; Marta Scorsetti
Journal:  Rep Pract Oncol Radiother       Date:  2012-08-10

4.  Radiosurgery with flattening-filter-free techniques in the treatment of brain metastases : Plan comparison and early clinical evaluation.

Authors:  J Rieber; E Tonndorf-Martini; O Schramm; B Rhein; S Stefanowicz; J Kappes; H Hoffmann; K Lindel; J Debus; S Rieken
Journal:  Strahlenther Onkol       Date:  2016-07-04       Impact factor: 3.621

5.  Stereotactic body radiation therapy for liver tumours using flattening filter free beam: dosimetric and technical considerations.

Authors:  Pietro Mancosu; Simona Castiglioni; Giacomo Reggiori; Maddalena Catalano; Filippo Alongi; Chiara Pellegrini; Stefano Arcangeli; Angelo Tozzi; Francesca Lobefalo; Antonella Fogliata; Piera Navarria; Luca Cozzi; Marta Scorsetti
Journal:  Radiat Oncol       Date:  2012-02-01       Impact factor: 3.481

6.  Planning study of flattening filter free beams for volumetric modulated arc therapy in squamous cell carcinoma of the scalp.

Authors:  Youqun Lai; Liwan Shi; Qin Lin; Lirong Fu; Huiming Ha
Journal:  PLoS One       Date:  2014-12-15       Impact factor: 3.240

7.  Safety of high-dose-rate stereotactic body radiotherapy.

Authors:  Sonja Stieb; Stephanie Lang; Claudia Linsenmeier; Shaun Graydon; Oliver Riesterer
Journal:  Radiat Oncol       Date:  2015-01-23       Impact factor: 3.481

8.  Volumetric modulated arc therapy with flattening filter free beams for isolated abdominal/pelvic lymph nodes: report of dosimetric and early clinical results in oligometastatic patients.

Authors:  Filippo Alongi; Antonella Fogliata; Elena Clerici; Pierina Navarria; Angelo Tozzi; Tiziana Comito; Anna Maria Ascolese; Alessandro Clivio; Francesca Lobefalo; Giacomo Reggiori; Luca Cozzi; Pietro Mancosu; Stefano Tomatis; Marta Scorsetti
Journal:  Radiat Oncol       Date:  2012-12-05       Impact factor: 3.481

9.  A dosimetric evaluation of flattening filter-free volumetric modulated arc therapy in nasopharyngeal carcinoma.

Authors:  Guishan Fu; Minghui Li; Yixin Song; Jianrong Dai
Journal:  J Med Phys       Date:  2014-07

10.  Dosimetric differences in flattened and flattening filter-free beam treatment plans.

Authors:  Yue Yan; Poonam Yadav; Michael Bassetti; Kaifang Du; Daniel Saenz; Paul Harari; Bhudatt R Paliwal
Journal:  J Med Phys       Date:  2016 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.