Literature DB >> 22318465

[Registration strategies for the application of the navigation system Fiagon at the lateral scull base].

J Kristin1, D Mucha, J Schipper, T Klenzner.   

Abstract

OBJECTIVE: The aim of this study was to evaluate a new navigation system (Fiagon GmbH) at the lateral skull base.
MATERIAL AND METHODS: We performed repeated measurements and registrations on titanium screws, which were attached to specific anatomical locations on 5 temporal bone specimens. The focus of the investigation is to determinate the Target Registration Error and a comparison of different registration methods.
RESULTS: Use of the navigation system seems to be practicable at the lateral scull base. For a registration strategy with 3 onesided attached Fiducials the Target Registration Error is 0.8 mm on the surface of the mastoid and in the mastoid cavity. The measurements at the inner ear canal showed a mean deviation of greater than 1.6 mm. In the comparison of different registration methods the best results were found for registration on titanium screws attached on both sides of the head, followed by surface registration at the face including laterobasis followed by registration in the mastoid cavity only.
CONCLUSION: The measured values correspond to our clinical expectations and can be used if the existing Target Registration Error is known and respected. An intra-operative imaging may allow the application of titanium screws for navigation (gold standard) within the same general anesthesia during surgery. © Georg Thieme Verlag KG Stuttgart · New York.

Mesh:

Substances:

Year:  2012        PMID: 22318465     DOI: 10.1055/s-0031-1299755

Source DB:  PubMed          Journal:  Laryngorhinootologie        ISSN: 0935-8943            Impact factor:   1.057


  4 in total

1.  The comparative accuracy of the ROSA stereotactic robot across a wide range of clinical applications and registration techniques.

Authors:  Nicholas J Brandmeir; Sandip Savaliya; Pratik Rohatgi; Michael Sather
Journal:  J Robot Surg       Date:  2017-05-08

2.  Prospects and limitations of different registration modalities in electromagnetic ENT navigation.

Authors:  Eric Soteriou; Juergen Grauvogel; Roland Laszig; Tanja Daniela Grauvogel
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-05-05       Impact factor: 2.503

3.  Accuracy and feasibility of a dedicated image guidance solution for endoscopic lateral skull base surgery.

Authors:  Christoph Rathgeb; Lukas Anschuetz; Daniel Schneider; Cilgia Dür; Marco Caversaccio; Stefan Weber; Tom Williamson
Journal:  Eur Arch Otorhinolaryngol       Date:  2018-02-13       Impact factor: 2.503

4.  Evolution and Stagnation of Image Guidance for Surgery in the Lateral Skull: A Systematic Review 1989-2020.

Authors:  Daniel Schneider; Jan Hermann; Fabian Mueller; Gabriela O'Toole Bom Braga; Lukas Anschuetz; Marco Caversaccio; Lutz Nolte; Stefan Weber; Thomas Klenzner
Journal:  Front Surg       Date:  2021-01-11
  4 in total