A potential MRI hazard: forces on dental magnet keepers.

A G Gegauff1, K A Laurell, A Thavendrarajah, S F Rosenstiel.   

Abstract

The objective of this study was to determine the forces on dental prosthetic magnet keepers, with a view to assessing the potential for patient injury during magnetic resonance imaging (MRI). Four pre-formed keepers and one castable keeper alloy were tested. Magnetizations and high field susceptibilities were determined for each of the five specimens using data from a vibrating sample magnetometer. The magnetic field intensity with respect to distance from the main magnet coil was obtained from the manufacturer (1-5 tesla General Electric Signa Imaging System). A plot of force versus distance from the main coil and the maximum force at the magnet portal was determined for each specimen. The maximum forces ranged from 0.12-0.24 N for the pre-formed keepers and 3.67 MNm-3 for the castable alloy. It was concluded that the risk of patient injury by displacement is minimal, if the keepers are properly attached to supporting structures.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2231158     DOI: 10.1111/j.1365-2842.1990.tb01411.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  5 in total

1.  Radiofrequency heating and magnetically induced displacement of dental magnetic attachments during 3.0 T MRI.

Authors:  K Miyata; M Hasegawa; Y Abe; T Tabuchi; T Namiki; T Ishigami
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

2.  Experience with magnetic resonance imaging of human subjects with passive implants and tattoos at 7 T: a retrospective study.

Authors:  Yacine Noureddine; Andreas K Bitz; Mark E Ladd; Markus Thürling; Susanne C Ladd; Gregor Schaefers; Oliver Kraff
Journal:  MAGMA       Date:  2015-09-26       Impact factor: 2.310

3.  Magnetization and demagnetization of magnetic dental attachments in a 3-T MRI system.

Authors:  Norio Hayashi; Akio Ogura; Toshio Tsuchihashi; Daisuke Takahashi; Tsuyoshi Matsuda; Shinya Seino; Tsukasa Doi
Journal:  Radiol Phys Technol       Date:  2017-04-27

4.  Radiofrequency heating of metallic dental devices during 3.0 T MRI.

Authors:  M Hasegawa; K Miyata; Y Abe; T Ishigami
Journal:  Dentomaxillofac Radiol       Date:  2013-03-21       Impact factor: 2.419

5.  Interactions between magnetic resonance imaging and dental material.

Authors:  Chalakuzhiyl Abraham Mathew; Sudhakara Maller
Journal:  J Pharm Bioallied Sci       Date:  2013-06