Literature DB >> 22309739

Root perforation associated with the use of a miniscrew implant used for orthodontic anchorage: a case report.

P McCabe1, C Kavanagh.   

Abstract

AIM: To highlight one of the possible complications associated with the inter-radicular placement of orthodontic miniscrews.
SUMMARY: This case report describes the endodontic treatment and surgical repair of an iatrogenic root perforation involving a maxillary first molar tooth following the placement of an orthodontic miniscrew placed for anchorage purposes in the treatment of an adult patient. The orthodontic treatment plan was completed. The long-term follow-up shows a successful treatment outcome. KEY LEARNING POINTS: Inter-radicular placement of orthodontic miniscrews is a valuable source of anchorage in the treatment of orthodontic patients. Root perforation is a possible complication from inter-radicular placement of orthodontic miniscrews. Root perforation can be successfully treated, but may involve apical surgery.
© 2012 International Endodontic Journal.

Entities:  

Mesh:

Year:  2012        PMID: 22309739     DOI: 10.1111/j.1365-2591.2012.02022.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  7 in total

1.  Skeletal anchorage for everybody? a questionnaire study on frequency of use and clinical indications in daily practice.

Authors:  N C Bock; S Ruf
Journal:  J Orofac Orthop       Date:  2015-03       Impact factor: 1.938

2.  A comparative study between currently used methods and Small Volume-Cone Beam Tomography for surgical placement of mini implants.

Authors:  Melissa Landin; Aniket Jadhav; Sumit Yadav; Aditya Tadinada
Journal:  Angle Orthod       Date:  2014-10-24       Impact factor: 2.079

3.  Incidence of pulp sensibility loss of anterior teeth after paramedian insertion of orthodontic mini-implants in the anterior maxilla.

Authors:  Jan Hourfar; Dirk Bister; Jörg A Lisson; Björn Ludwig
Journal:  Head Face Med       Date:  2017-01-06       Impact factor: 2.151

4.  Cementum and dentin repair following root damage caused by the insertion of self-tapping and self-drilling miniscrews.

Authors:  Majid Ghanbarzadeh; Farzin Heravi; Reihaneh Abrishamchi; Hooman Shafaee; Narges Ghazi; Parya Heravi; Hamid Ghanbarzadeh
Journal:  J Orthod Sci       Date:  2017 Jul-Sep

5.  Complications reported with the use of orthodontic miniscrews: A systematic review.

Authors:  Antonino Lo Giudice; Lorenzo Rustico; Miriam Longo; Giacomo Oteri; Moschos A Papadopoulos; Riccardo Nucera
Journal:  Korean J Orthod       Date:  2021-05-25       Impact factor: 1.372

Review 6.  Revisiting the Complications of Orthodontic Miniscrew.

Authors:  Van Mai Truong; Soyeon Kim; Jaeheon Kim; Joo Won Lee; Young-Seok Park
Journal:  Biomed Res Int       Date:  2022-08-01       Impact factor: 3.246

7.  Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites.

Authors:  Aditya Tadinada; Alana Marczak; Sumit Yadav
Journal:  Imaging Sci Dent       Date:  2017-09-21
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.