Literature DB >> 22309295

Comparison of analog 2D and digital 3D preoperative templating for predicting implant size in total knee arthroplasty.

Atsushi Kobayashi1, Yoshinori Ishii, Mitsuhiro Takeda, Hideo Noguchi, Hiroshi Higuchi, Sinichi Toyabe.   

Abstract

The aim of this study was to compare the accuracy of preoperative templating in total knee arthroplasty (TKA) using conventional two-dimensional (2D) and computed tomography (CT)-based three-dimensional (3D) procedures, and to confirm the necessity of 3D evaluation for preoperative planning. One hundred consecutive primary TKAs were analyzed. Preoperative templating was performed for each TKA using both conventional 2D radiographs and a CT-based 3D image model created using KneeCAS software. Accuracies with regard to the predicted and actual implant sizes were determined for each procedure. The 3D procedure was found to be more accurate (59%) than the 2D procedure (56%) in predicting implant size, but the difference was not statistically significant (p = 0.67). Computer-assisted surgery systems are often used for preoperative planning in TKA. However, our results do not support the superiority of 3D preoperative templating over 2D conventional evaluation in predicting implant size. Thus, 3D templating may not be necessary for preoperatively predicting implant size in TKA, and can only be used as an approximate guide.

Entities:  

Mesh:

Year:  2012        PMID: 22309295     DOI: 10.3109/10929088.2011.651488

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  4 in total

1.  CT-based TruMatch® Personal Solutions for knee replacement Surgery … Does it really match?

Authors:  Amila N Silva; You Wei Adriel Tay; Sharon Tan Si Heng; Siang Shen Leon Foo; Hee Nee Pang; Darren Tay Keng Jin; Ngai Nung Lo; Seng Jin Yeo
Journal:  J Orthop       Date:  2019-11-27

2.  A novel technology for 3D knee prosthesis planning and treatment evaluation using 2D X-ray radiographs: a clinical evaluation.

Authors:  Guoyan Zheng; Hagen Hommel; Alper Akcoltekin; Benedikt Thelen; Jan Stifter; Geert Peersman
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-05-21       Impact factor: 2.924

3.  Improved accuracy and fewer outliers with a novel CT-free robotic THA system in matched-pair analysis with manual THA.

Authors:  Atul F Kamath; Sridhar M Durbhakula; Trevor Pickering; Nathan L Cafferky; Trevor G Murray; Michael A Wind; Stéphane Méthot
Journal:  J Robot Surg       Date:  2021-10-28

4.  A computational tool for automatic selection of total knee replacement implant size using X-ray images.

Authors:  Thomas A Burge; Gareth G Jones; Christopher M Jordan; Jonathan R T Jeffers; Connor W Myant
Journal:  Front Bioeng Biotechnol       Date:  2022-09-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.