Literature DB >> 22308623

Metal ion levels decrease after revision for metallosis arising from large-diameter metal-on-metal hip arthroplasty.

Darren Ebreo1, Abdul Khan, Mohammed El-Meligy, Catherine Armstrong, Viju Peter.   

Abstract

Concerns have been renewed regarding the possible long-term effects of elevated circulating levels of cobalt and chromium as a direct result of implantation of large femoral head diameter metal-on-metal bearings. In order to establish whether metal ion levels remain persistently elevated, we compared metal ion levels before and after revision surgery in patients with large head diameter (greater than 38 mm) metal-on-metal total hip arthroplasty or hip resurfacing arthroplasty. At greater than one year post removal of a large-diameter metal-on-metal hip implant for the indication of symptomatic metallosis, metal ion levels were found to fall to almost normal levels.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22308623

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  8 in total

1.  Revision of Metal-on-metal Hip Prostheses Results in Marked Reduction of Blood Cobalt and Chromium Ion Concentrations.

Authors:  Olli Lainiala; Aleksi Reito; Petra Elo; Jorma Pajamäki; Timo Puolakka; Antti Eskelinen
Journal:  Clin Orthop Relat Res       Date:  2015-01-27       Impact factor: 4.176

Review 2.  Management of metal-on-metal hip implant patients: Who, when and how to revise?

Authors:  Reshid Berber; John A Skinner; Alister J Hart
Journal:  World J Orthop       Date:  2016-05-18

3.  The natural history of inflammatory pseudotumors in asymptomatic patients after metal-on-metal hip arthroplasty.

Authors:  Sulaiman A Almousa; Nelson V Greidanus; Bassam A Masri; Clive P Duncan; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

Review 4.  Do retrieval analysis and blood metal measurements contribute to our understanding of adverse local tissue reactions?

Authors:  Patricia A Campbell; Michael S Kung; Andrew R Hsu; Joshua J Jacobs
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

5.  Normalization of chromium and cobalt values after femoral head replacement.

Authors:  Claudio Iacobellis; Antonio Berizzi; Assunta Pozzuoli; Carlo Biz
Journal:  Int J Surg Case Rep       Date:  2015-03-27

6.  Revision surgery of metal-on-metal hip arthroplasties for adverse reactions to metal debris.

Authors:  Gulraj S Matharu; Antti Eskelinen; Andrew Judge; Hemant G Pandit; David W Murray
Journal:  Acta Orthop       Date:  2018-03-01       Impact factor: 3.717

7.  Course of Metal Ions after a Revision of Malfunctioning Metal-on-Metal Total Hip Prostheses.

Authors:  Annamaria Nicolli; Isabella Bortoletti; Stefano Maso; Andrea Trevisan
Journal:  Medicina (Kaunas)       Date:  2021-01-28       Impact factor: 2.430

Review 8.  Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties: a literature overview.

Authors:  Christopher Jantzen; Henrik L Jørgensen; Benn R Duus; Sune L Sporring; Jes B Lauritzen
Journal:  Acta Orthop       Date:  2013-04-18       Impact factor: 3.717

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.