Literature DB >> 2230854

Auscultatory mean blood pressure.

G J Davis1, L A Geddes.   

Abstract

This study examined the relationship between direct mean arterial blood pressure and cuff pressure for the maximum acoustic index calculated from the Korotkoff sounds in the dog. The acoustic index was computed by summing the squares of amplitudes in each Korotkoff sound complex, thereby providing a measure of acoustic energy content. Mean arterial pressure was compared with cuff pressure for the maximum acoustic index. Ten mongrel dogs were fitted with appropriately sized blood-pressure cuffs containing a microphone mounted inside the bladder and positioned over the brachial artery. The Korotkoff sounds, cuff pressure, and direct arterial pressure were recorded over a range of mean arterial pressures (23 to 155 mm Hg), achieved by manipulating the depth of anesthesia with halothane. It was found that cuff pressure at the maximum acoustic index overestimated mean arterial blood pressure by a mean of 14% (range, -8 to +30%).

Entities:  

Mesh:

Year:  1990        PMID: 2230854     DOI: 10.1007/bf02842484

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  6 in total

1.  Recommendations for human blood pressure determinations by sphygmomanometers.

Authors:  J BORDLEY; C A R CONNOR; W F HAMILTON; W J KERR; C J WIGGERS
Journal:  Circulation       Date:  1951-10       Impact factor: 29.690

2.  The efficient detection of Korotkoff sounds.

Authors:  L A Geddes; A G Moore
Journal:  Med Biol Eng       Date:  1968-11

3.  Recommendations for human blood pressure determination by sphygmomanometers. Subcommittee of the AHA Postgraduate Education Committee.

Authors:  W M Kirkendall; M Feinleib; E D Freis; A L Mark
Journal:  Hypertension       Date:  1981 Jul-Aug       Impact factor: 10.190

4.  Characterization of the oscillometric method for measuring indirect blood pressure.

Authors:  L A Geddes; M Voelz; C Combs; D Reiner; C F Babbs
Journal:  Ann Biomed Eng       Date:  1982       Impact factor: 3.934

5.  The error in indirect blood pressure measurement with the incorrect size of cuff.

Authors:  L A Geddes; S J Whistler
Journal:  Am Heart J       Date:  1978-07       Impact factor: 4.749

6.  Indirect auscultatory systolic and diastolic pressures in the anesthetized dog.

Authors:  J L Wessale; L A Smith; M Reid; W Janas; A B Carter; L A Geddes
Journal:  Am J Vet Res       Date:  1985-10       Impact factor: 1.156

  6 in total
  1 in total

1.  Comparison of intraarterial with continuous noninvasive blood pressure measurement in postoperative pediatric patients.

Authors:  J K Triedman; J P Saul
Journal:  J Clin Monit       Date:  1994-01
  1 in total