Literature DB >> 22304743

Effect of surface conditioning with airborne-particle abrasion on the tensile strength of polymeric CAD/CAM crowns luted with self-adhesive and conventional resin cements.

Bogna Stawarczyk1, Tobias Basler, Andreas Ender, Malgorzata Roos, Mutlu Ozcan, Christoph Hämmerle.   

Abstract

STATEMENT OF PROBLEM: Adhesively bonded, industrially polymerized resins have been suggested as definitive restorative materials. It is claimed that such resins present similar mechanical properties to glass ceramic.
PURPOSE: The purpose of this study was to assess the tensile strength of polymeric crowns after conditioning with 2 different protocols: luted with self-adhesive or with conventional resin cements to dental abutments.
MATERIAL AND METHODS: Human teeth were prepared for crowns and divided into 13 groups (N=312, n=24 per group). Polymeric crowns were CAD/CAM fabricated and divided into 3 groups depending on different surface conditioning methods: A) No treatment, B) airborne-particle abrasion with 50 μm alumina, and C) airborne-particle abrasion with 110 μm alumina. Thereafter, the crowns were luted on dentin abutments with the following cements: 1) RXU (RelyX Unicem, self-adhesive), 2) GCM (G-Cem, self-adhesive), 3) ACG (artCem GI, conventional), and 4) VAR (Variolink II, conventional). Glass ceramic crowns milled and cemented with dual-polymerized resin cement (Variolink II) served as the control group. The tensile strength was measured initially (n=12) and after aging by mechanical thermocycling loading (1 200 000 cycles, 49 N, 5°C to 50°C) (n=12). The tensile strength (MPa) of all crowns was determined by the pull-off test (Zwick/Roell Z010; Ulm, Germany, 1mm/min). Subsequently, the failure types were classified. Data were analyzed with 2-way and 1-way ANOVA followed by a post hoc Scheffé test and t test (α=.05).
RESULTS: No adhesion of the tested cements was observed on unconditioned polymeric CAD/CAM crowns and those luted with VAR. Among the tested cements, GCM showed significantly higher values after airborne-particle abrasion with 110 μm (initial: 2.8 MPa; after aging: 1 MPa) than 50 μm alumina (initial: 1.4 MPa; after aging: 0 MPa). No significant effect was found between 50 and 110 μm particle size alumina in combination with the other 2 cements. After aging, the tensile strength of the crowns luted with GCM (50 μm: 0 MPa and 110 μm: 1 MPa) and ACG (50 μm: 1 MPa and 110 μm: 1.2 MPa) was significantly lower than those luted with RXU (50 μm: 1.9 MPa and 110 μm: 2 MPa). All airborne particle abraded polymeric CAD/CAM crowns (initial: 1.4-2.8; 0-2 MPa) showed significantly lower tensile strength values than the control group (initial: 7.3 MPa; after aging: 6.4 MPa). Although with all polymeric specimens, failure type was adhesive between the cement and the crowns, the control group showed exclusively cohesive failures within the ceramic.
CONCLUSIONS: Airborne-particle abrasion before cementation of polymeric CAD/CAM crowns minimally improved the tensile strength. Both the failure types and the tensile strength values of adhesively luted glass ceramic crowns showed superior results to adhesively cemented polymeric ones. Although the tensile strength results were low, crowns cemented with RXU showed, after aging, the highest tensile strength of all other tested groups.
Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22304743     DOI: 10.1016/S0022-3913(12)60031-6

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  20 in total

1.  Repairability of CAD/CAM high-density PMMA- and composite-based polymers.

Authors:  Annette Wiegand; Lukas Stucki; Robin Hoffmann; Thomas Attin; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2015-02-05       Impact factor: 3.573

2.  Bonding between CAD/CAM resin and resin composite cements dependent on bonding agents: three different in vitro test methods.

Authors:  Simona Gilbert; Christine Keul; Malgorzata Roos; Daniel Edelhoff; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2015-05-24       Impact factor: 3.573

3.  Transmission of light in the visible spectrum (400-700 nm) and blue spectrum (360-540 nm) through CAD/CAM polymers.

Authors:  Jan-Frederik Güth; Ana Elisa Colle Kauling; Kazuhiko Ueda; Beuer Florian; Michael Stimmelmayr
Journal:  Clin Oral Investig       Date:  2016-02-26       Impact factor: 3.573

4.  In-vitro performance of CAD/CAM-fabricated implant-supported temporary crowns.

Authors:  Martin Rosentritt; Philipp Raab; Sebastian Hahnel; Matthias Stöckle; Verena Preis
Journal:  Clin Oral Investig       Date:  2017-01-21       Impact factor: 3.573

5.  The effect of different pretreatment methods of PMMA-based crowns on the long-term tensile bond strength to dentin abutments.

Authors:  Christine Keul; Daliah Kohen; Marlis Eichberger; Malgorzata Roos; Wolfgang Gernet; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2014-03-02       Impact factor: 3.573

6.  Tensile bond strength of resin composite repair in vitro using different surface preparation conditionings to an aged CAD/CAM resin nanoceramic.

Authors:  Bogna Stawarczyk; Andreas Krawczuk; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2014-06-15       Impact factor: 3.573

7.  Effect of surface treatments and flash-free adhesive on the shear bond strength of ceramic orthodontic brackets to CAD/CAM provisional materials.

Authors:  Tarek Ahmed Soliman; Sayed Ghorab; Hossam Baeshen
Journal:  Clin Oral Investig       Date:  2021-10-04       Impact factor: 3.573

8.  Influence of different luting protocols on shear bond strength of computer aided design/computer aided manufacturing resin nanoceramic material to dentin.

Authors:  Claudio Poggio; Marco Pigozzo; Matteo Ceci; Andrea Scribante; Riccardo Beltrami; Marco Chiesa
Journal:  Dent Res J (Isfahan)       Date:  2016 Mar-Apr

9.  Effects of air abrasion with alumina or glass beads on surface characteristics of CAD/CAM composite materials and the bond strength of resin cements.

Authors:  Arao Nobuaki; Yoshida Keiichi; Sawase Takashi
Journal:  J Appl Oral Sci       Date:  2015 Nov-Dec       Impact factor: 2.698

10.  Effect of glycine pretreatment on the shear bond strength of a CAD/CAM resin nano ceramic material to dentin.

Authors:  Matteo Ceci; Marco Pigozzo; Andrea Scribante; Riccardo Beltrami; Marco Colombo; Marco Chiesa; Claudio Poggio
Journal:  J Clin Exp Dent       Date:  2016-04-01