Literature DB >> 22297852

Tracking a therapeutic response: how reliable are serial measurements of LV perfusion and function?

Guido Germano1, Paul B Kavanagh, Piotr J Slomka, Daniel S Berman.   

Abstract

Entities:  

Mesh:

Year:  2012        PMID: 22297852      PMCID: PMC3569509          DOI: 10.1007/s12350-012-9518-9

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


× No keyword cloud information.
  9 in total

1.  Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging.

Authors:  Claudia S A Lipke; Harald P Kühl; Bernd Nowak; Hans-Juergen Kaiser; Patrick Reinartz; Karl-Christian Koch; Udalrich Buell; Wolfgang M Schaefer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-01-14       Impact factor: 9.236

2.  Automated quantification of myocardial perfusion SPECT using simplified normal limits.

Authors:  Piotr J Slomka; Hidetaka Nishina; Daniel S Berman; Cigdem Akincioglu; Aiden Abidov; John D Friedman; Sean W Hayes; Guido Germano
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

3.  Detecting changes in serial myocardial perfusion SPECT: a simulation study.

Authors:  Tracy L Faber; Jan Modersitzki; Russell D Folks; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2005 May-Jun       Impact factor: 5.952

4.  Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" filtered backprojection.

Authors:  E Gordon DePuey; Ramesh Gadiraju; John Clark; Linda Thompson; Frank Anstett; Shuli C Shwartz
Journal:  J Nucl Cardiol       Date:  2008-04-24       Impact factor: 5.952

5.  Automatic and visual reproducibility of perfusion and function measures for myocardial perfusion SPECT.

Authors:  Yuan Xu; Sean Hayes; Iftikhar Ali; Terrence D Ruddy; R Glenn Wells; Daniel S Berman; Guido Germano; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2010-10-21       Impact factor: 5.952

6.  Effects of age, gender, obesity, and diabetes on the efficacy and safety of the selective A2A agonist regadenoson versus adenosine in myocardial perfusion imaging integrated ADVANCE-MPI trial results.

Authors:  Manuel D Cerqueira; Patricia Nguyen; Peter Staehr; S Richard Underwood; Ami E Iskandrian
Journal:  JACC Cardiovasc Imaging       Date:  2008-05

7.  Gated myocardial perfusion SPECT: algorithm-specific influence of reorientation on calculation of left ventricular volumes and ejection fraction.

Authors:  Daniela Knollmann; Oliver H Winz; Philipp T Meyer; Mardjan Raptis; Thomas Krohn; Karl-Christian Koch; Wolfgang M Schaefer
Journal:  J Nucl Med       Date:  2008-09-15       Impact factor: 10.057

8.  Automatic quantification of myocardial perfusion stress-rest change: a new measure of ischemia.

Authors:  Piotr J Slomka; Hidetaka Nishina; Daniel S Berman; Xingping Kang; John D Friedman; Sean W Hayes; Usaf E Aladl; Guido Germano
Journal:  J Nucl Med       Date:  2004-02       Impact factor: 10.057

9.  Quantitative assessment of myocardial perfusion abnormality on SPECT myocardial perfusion imaging is more reproducible than expert visual analysis.

Authors:  Daniel S Berman; Xingping Kang; Heidi Gransar; James Gerlach; John D Friedman; Sean W Hayes; Louise E J Thomson; Rory Hachamovitch; Leslee J Shaw; Piotr J Slomka; Ling De Yang; Guido Germano
Journal:  J Nucl Cardiol       Date:  2009-01-20       Impact factor: 5.952

  9 in total
  8 in total

1.  SPECT myocardial perfusion imaging as an endpoint.

Authors:  Melody Sherwood; Fadi G Hage; Jack Heo; Leslee J Shaw; Manuel D Cerqueira; Ami E Iskandrian
Journal:  J Nucl Cardiol       Date:  2012-10       Impact factor: 5.952

Review 2.  Serial imaging and outcome prediction.

Authors:  Ami E Iskandrian; Christopher P Roth; Fadi G Hage
Journal:  J Nucl Cardiol       Date:  2015-10-30       Impact factor: 5.952

Review 3.  Gated SPECT in assessment of regional and global left ventricular function: an update.

Authors:  Aiden Abidov; Guido Germano; Rory Hachamovitch; Piotr Slomka; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2013-12       Impact factor: 5.952

4.  Quantitative measurements of myocardial perfusion and function from SPECT (and PET) studies depend on the method used to perform those measurements.

Authors:  Guido Germano
Journal:  J Nucl Cardiol       Date:  2016-12-21       Impact factor: 5.952

5.  The "gray zone" for the heart to mediastinum MIBG uptake ratio.

Authors:  Mario Petretta; Teresa Pellegrino; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2014-05-09       Impact factor: 5.952

6.  "Same-patient processing" for multiple cardiac SPECT studies. 2. Improving quantification repeatability.

Authors:  Guido Germano; Paul B Kavanagh; Terrence D Ruddy; R Glenn Wells; Yuan Xu; Daniel S Berman; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2016-10-14       Impact factor: 5.952

7.  Observer reproducibility of results from a low-dose 123I-metaiodobenzylguanidine cardiac imaging protocol in patients with heart failure.

Authors:  Teresa Pellegrino; Mario Petretta; Serena De Luca; Stefania Paolillo; Antonio Boemio; Raffaella Carotenuto; Maria Piera Petretta; Carmine di Nuzzo; Pasquale Perrone-Filardi; Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-06-06       Impact factor: 9.236

8.  A prospective evaluation of the repeatability of left ventricular ejection fraction measurement by gated SPECT.

Authors:  Dustin Kliner; Li Wang; Daniel Winger; William P Follansbee; Prem Soman
Journal:  J Nucl Cardiol       Date:  2015-02-20       Impact factor: 5.952

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.