Marek Maciejewski1, Katarzyna Piestrzeniewicz, Agata Bielecka-Dąbrowa, Monika Piechowiak, Ryszard Jaszewski.
Abstract
INTRODUCTION: The aim of the study was to analyse the risk factors of early and late mortality in patients undergoing the first reoperation for prosthetic valve dysfunction.Entities:
Keywords: echocardiography; prosthetic valve; reoperation
Year: 2011 PMID: 22291767 PMCID: PMC3258715 DOI: 10.5114/aoms.2011.22078
Source DB: PubMed Journal: Arch Med Sci ISSN: 1734-1922 Impact factor: 3.318
Characteristics of the entire study group - 194 patients reoperated on for a prosthetic valve (PV) dysfunction
| 53.2 ±11 (18-74) | |||
| 75 (39)/119 | |||
| 83.4 ±65.6 (1-230) | |||
| 22 (12.4) | |||
| 38 (19.6) | |||
| 132 (68.0) | |||
| 42 (21.7) | |||
| 145 (74.7) | |||
| 105 (54.1) | |||
| 103 (53.1)/91 | |||
| 17 (8.7) | |||
| Structural dysfunction of mechanical PV | 6 (3.1) | ||
| Structural dysfunction of bioprosthesis | 76 (39.2) | ||
| Infectious endocarditis | 58 (29.9) | ||
| Disc blockage by thrombus | 30 (15.5) | ||
| Paravalvular shunt | 17 (8.8) | ||
| Other | 7 (3.6) | ||
Temporal prosthetic valve dysfunction of unknown aetiology - 3 patients, pannus - 2 patients, “small” prosthetic valve - 2 patients, NYHA - New York Heart Association, PV - prosthetic valve
Clinical and echocardiographic predictors of death in early postoperative period in 194 patients reoperated on for prosthetic valve dysfunction
| 54.2 ±10.3, 21-71 | 53.0 ±11.3, 18-74 | NS | |||
| 12/24 | 65/93 | NS | |||
| 14 | 28 | < 0.01 | |||
| 33 | 72 | < 0.001 | |||
| 45.9 ±63, 8, 1-224 | 92.1 ±62, 96, 1-230 | < 0.001 | |||
| 11 | 14 | ||||
| 20 | 17 | ||||
| 5 | 127 | ||||
| 30 | 129 | NS | |||
| 6 | 29 | NS | |||
| 27/9 | 76/82 | < 0.005 | |||
| 9 | 33 | NS | |||
| 14 | 44 | < 0.001 | |||
| 33 | 112 | < 0.02 | |||
| 3 | 2 | < 0.05 | |||
| 7 | 6 | < 0.05 | |||
| 22 | 54 | < 0.01 | |||
med. - median, PVI - prosthetic valve implantation
Clinical and echocardiographic predictors of perioperative death in patients referred for reoperation due to causes of prosthetic valve dysfunction other than endocarditis
| Death ( | Survival ( | Value of | |||
|---|---|---|---|---|---|
| 54.57 ±8.7 (38-69) | 53.91 ±10.7 (18-73) | NS | |||
| 4/18 | 40/74 | NS | |||
| 5 | 20 | NS | |||
| 20 | 48 | < 0.001 | |||
| 105.9 ±60, 114, 0-230 | < 0.02 | ||||
| 7 | 8 | ||||
| 12 | 7 | ||||
| 3 | 99 | ||||
| 20 | 93 | NS | |||
| 2 | 21 | NS | |||
| 15/7 | 45/69 | < 0.02 | |||
| 6 | 23 | NS | |||
| 15 | 45 | - | |||
| 7 | 23 | NS | |||
| 5 | 12 | NS | |||
| 2 | 4 | NS | |||
| 1 | 6 | NS | |||
| 21 | 84 | < 0.01 | |||
| 11 | 40 | NS | |||
PVI - prosthetic valve implantation,
refers to patients operated on for mechanical prosthetic valve dysfunction
Characteristics of patients reoperated on for prosthetic valve (PV) dysfunction due to infective endocarditis (IE +) and other reasons (IE -)
| 51.43 ±12.49 (21-74) | 54.0 ±10.4 (18-73) | NS | |||
| 31/27 | 44/92 | < 0.01 | |||
| 49.3 ±56, 15, 1-190 | 98.9 ±64, 109, 1-230 | < 0.001 | |||
| 13 (22.4) | 76 (55.9) | < 0.001 | |||
| Disc blockage | 16 (35.6) | 30 (50.0) | NS | ||
| Paravalvular leak | 24 (53.3) | 17 (28.3) | < 0.02 | ||
| DB + PL | 5 (11.1) | - | - | ||
| Other | - | 13 (21.7) | - | ||
med. - median, IE - endocarditis, PVI - prosthetic valve implantation