Literature DB >> 22290622

Three-dimensional arbitrary voxel shapes in spectroscopy with submillisecond TEs.

Jeff Snyder1, Martin Haas, Iulius Dragonu, Jürgen Hennig, Maxim Zaitsev.   

Abstract

A novel spectroscopic method for submillisecond TEs and three-dimensional arbitrarily shaped voxels was developed and applied to phantom and in vivo measurements, with additional parallel excitation (PEX) implementation. A segmented spherical shell excitation trajectory was used in combination with appropriate radiofrequency weights for target selection in three dimensions. Measurements in a two-compartment phantom realized a TE of 955 µs, excellent spectral quality and comparable signal-to-noise ratios between accelerated (R = 2) and nonaccelerated modes. The two-compartment model allowed a comparison of the spectral suppression qualities of the method and, although outer volume signals were suppressed by factors of 1434 and 2246 compared with the theoretical unsuppressed case for the clinical and PEX modes, respectively, incomplete suppression of the outer volume (935 cm(3) compared with a target volume of 5.86 cm(3) ) resulted in a spectral contamination of 10.2% and 6.5% compared with the total signal. The method was also demonstrated in vivo in human brain on a clinical system at TE = 935 µs with good signal-to-noise ratio and spatial and spectral selection, and included LCModel relative quantification analysis. Eight metabolites showed significant fitting accuracy, including aspartate, N-acetylaspartylglutamate, glutathione and glutamate.
Copyright © 2012 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2012        PMID: 22290622     DOI: 10.1002/nbm.2764

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  3 in total

1.  Signal scaling improves the signal-to-noise ratio of measurements with segmented 2D-selective radiofrequency excitations.

Authors:  Jürgen Finsterbusch; Martin G Busch; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2013-02-25       Impact factor: 4.668

2.  Parallel transmit optimized 3D composite adiabatic spectral-spatial pulse for spectroscopy.

Authors:  Xiaoxuan He; Edward J Auerbach; Michael Garwood; Naoharu Kobayashi; Xiaoping Wu; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2021-01-26       Impact factor: 3.737

3.  Reproducibility of Neurochemical Profile Quantification in Pregenual Cingulate, Anterior Midcingulate, and Bilateral Posterior Insular Subdivisions Measured at 3 Tesla.

Authors:  Nuno M P de Matos; Lukas Meier; Michael Wyss; Dieter Meier; Andreas Gutzeit; Dominik A Ettlin; Mike Brügger
Journal:  Front Hum Neurosci       Date:  2016-06-21       Impact factor: 3.169

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.