Literature DB >> 22288871

Point-of-care focused cardiac ultrasound for the assessment of thoracic aortic dimensions, dilation, and aneurysmal disease.

R Andrew Taylor1, Isabel Oliva, Reinier Van Tonder, John Elefteriades, James Dziura, Christopher L Moore.   

Abstract

OBJECTIVES: Thoracic aortic aneurysm and thoracic aortic dissection are related and potentially deadly diseases that present with nonspecific symptoms. Transthoracic echocardiography (TTE) may detect thoracic aortic pathology and is being increasingly performed by the emergency physician at the bedside; however, the accuracy of point-of-care (POC) focused cardiac ultrasound (FOCUS) for thoracic aortic aneurysm and thoracic aortic dissection has not been studied. The objective of this pilot study was to explore the agreement, sensitivity, and specificity of FOCUS for thoracic aortic dimensions, dilation, and aneurysm compared with CT angiography (CTA) as the reference standard.
METHODS: This study was a retrospective pilot analysis of image and chart data on consecutive patients presenting to an urban, academic emergency department (ED) between January 2008 and June 2010, who had both a FOCUS and a CTA for suspicion of thoracic aorta pathology. Thoracic aorta dimensions were measured from recordings by three ultrasound-trained emergency physicians blinded to any initial FOCUS and CTA results. CTA measurements were obtained by a radiologist blinded to the FOCUS results. Using cutoffs of 40 and 45 mm, we calculated the sensitivity and specificity of FOCUS for aortic dilation and aneurysm with the largest measurement on CT as the reference standard. Bland-Altman plots with 95% limits of agreement were used to demonstrate agreement for aortic measurements, kappa statistics to assess the degree of agreement between tests for aortic dilation, and intraclass correlation for interobserver and intraobserver variability.
RESULTS: Ninety-two patients underwent both FOCUS and CTA during the study period. Ten FOCUS studies had inadequate visualization for all measurements areas. Eighty-two patients were included in the final analysis. Mean (±SD) age was 58.1 (±16.6) years and 58.5% were male. Sensitivity, specificity, and the observed kappa value (95% confidence interval [CI]) between FOCUS and CTA for the presence of aortic dilation at the 40-mm cutoff were 0.77 (95% CI = 0.58 to 0.98), 0.95 (95% CI = 0.84 to 0.99), and 0.74 (95% CI = 0.58 to 0.90), respectively. The mean difference (95% limits of agreement) for the Bland-Altman plots was 0.6 mm (-5.3 to 6.5) for the sinuses of Valsalva, 4 mm (-2.7 to 10.7) for the sinotubular junction, 1.5 mm (-5.8 to 8.8) for the ascending aorta, and 2.2 mm (-5.9 to 10.3) for the descending aorta.
CONCLUSIONS: In this retrospective pilot study, FOCUS demonstrated good agreement with CTA measurements of maximal thoracic aortic diameter. FOCUS appears to be specific for aortic dilation and aneurysm when compared to CTA, but requires further prospective study.
© 2012 by the Society for Academic Emergency Medicine.

Entities:  

Mesh:

Year:  2012        PMID: 22288871     DOI: 10.1111/j.1553-2712.2011.01279.x

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  8 in total

1.  Acute ischemic stroke what is hidden behind?

Authors:  Joaquín Valle Alonso; David Martin; Harriet Kinderman; Islam Farhad; Peter Swallow; Aidan Siggers
Journal:  J Cardiol Cases       Date:  2017-08-30

2.  Evaluation of the Aortic Arch from the Suprasternal Notch View Using Focused Cardiac Ultrasound.

Authors:  Karen A Kinnaman; Heidi H Kimberly; Emanuele Pivetta; Elke Platz; Avni Chudgar; Alexander Adduci; Michael B Stone; Joshua S Rempell
Journal:  J Emerg Med       Date:  2016-01-29       Impact factor: 1.484

3.  Focused cardiac ultrasound (FOCUS) by emergency medicine residents in patients with suspected cardiovascular diseases.

Authors:  Davood Farsi; Skokoufeh Hajsadeghi; Mohammad Javad Hajighanbari; Mani Mofidi; Peyman Hafezimoghadam; Mahdi Rezai; Babak Mahshidfar; Samaneh Abiri; Saeed Abbasi
Journal:  J Ultrasound       Date:  2017-05-02

4.  Aortic dissection and thrombosis diagnosed by emergency ultrasound in a patient with leg pain and paralysis.

Authors:  Ann H Tsung; Leslie C Nickels; Giuliano De Portu; Eike F Flach; Latha Ganti Stead
Journal:  Case Rep Vasc Med       Date:  2013-01-31

5.  A Case of Syncope.

Authors:  Kristin H Dwyer; Joshua S Rempell
Journal:  Clin Pract Cases Emerg Med       Date:  2017-10-03

6.  Importance of Multiple-window Assessment for the Diagnosis of Ascending Aortic Dissection Using Point-of-care Ultrasound: Report of Three Cases.

Authors:  Virginia Zarama; María C Arango-Granados; Luis A Bustamante Cristancho
Journal:  Clin Pract Cases Emerg Med       Date:  2019-08-05

7.  Emergency Department Diagnosis of Multiple Mycotic Aneurysms in an HIV-Positive Patient Using Point-of-Care Ultrasound.

Authors:  Piyachat Sasipattarapong; Emily Johnson; Samuel Beckerman; Dana Sajed
Journal:  Cureus       Date:  2022-01-26

8.  Bedside ultrasound in resuscitation and the rapid ultrasound in shock protocol.

Authors:  Dina Seif; Phillips Perera; Thomas Mailhot; David Riley; Diku Mandavia
Journal:  Crit Care Res Pract       Date:  2012-10-24
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.